Count rate correction for pulse pileup in CdZnTe photon counting detectors

被引:0
|
作者
Kang, Yang [1 ,2 ]
Wu, Rui [1 ,2 ]
Li, Peizheng [1 ,2 ]
Li, Qingpei [1 ,2 ]
Yin, Ziang [1 ,2 ]
Wu, Sen [1 ,2 ]
Tan, Tingting [1 ,2 ]
Li, Yingrui [1 ,2 ,3 ]
Zha, Gangqiang [1 ,2 ,3 ]
机构
[1] Northwestern Polytech Univ, State Key Lab Solidificat Proc, Xian 710072, Peoples R China
[2] Northwestern Polytech Univ, MIIT Key Lab Radiat Detect Mat & Devices, Xian 710072, Peoples R China
[3] Northwestern Polytech Univ, MIIT Key Lab Radiat Detect Mat & Devices, Xian 710072, Peoples R China
关键词
Photon counting; Pulse pileup; CdZnTe detector; Count rate correction; X-RAY; CDTE;
D O I
10.1016/j.mssp.2024.108142
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the practical application of CdZnTe photon counting detectors, severe detector counting distortion can be caused by pulse pileup. A count rate correction method in this paper is proposed to solve this problem. In this method, the case where multi -photons are recorded by higher energy regions due to pulse pileup crossing the energy threshold is considered to calculate the true count rates under all energy bins. A verification method based on Poisson distribution is also proposed to evaluate the accuracy of the correction method. A 16 -pixel linear array CdZnTe photon counting detector was used for verification. Taking the dual -energy bin as an example, this method was introduced, and the true count rates of the high- and low -energy bins are successfully calculated. The result was highly consistent with the verification result, which proves the reliability of the proposed method.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] A new method for preventing pulse pileup in scintillation detectors
    Tanaka, E
    Ohmura, T
    Yamashita, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (02): : 327 - 339
  • [32] Non-uniformity correction for MARS photon-counting detectors
    Getzin, Matthew
    Li, Mengzhou
    Rundle, David S.
    Butler, Anthony P.
    Wang, Ge
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [33] Assessment of multi-energy inter-pixel coincidence counters for photon-counting detectors at the presence of charge sharing and pulse pileup: A simulation study
    Taguchi, Katsuyuki
    Iwanczyk, Jan S.
    MEDICAL PHYSICS, 2021, 48 (09) : 4909 - 4925
  • [34] Photon Counting Detectors for Mammography
    Danielsson, M.
    MEDICAL PHYSICS, 2009, 36 (06) : 2699 - +
  • [35] FPGA-Based Pulse Pileup Correction
    Haselman, M. D.
    Hauck, S.
    Lewellen, T. K.
    Miyaoka, R. S.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3105 - 3112
  • [36] Photon Counting: Detectors and Applications
    La Riviere, Patrick J.
    Das, Mini
    Journal of Medical Imaging, 2024, 11
  • [37] Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects
    Taguchi, Katsuyuki
    Zhang, Mengxi
    Frey, Eric C.
    Wang, Xiaolan
    Iwanczyk, Jan S.
    Nygard, Einar
    Hartsough, Neal E.
    Tsui, Benjamin M. W.
    Barber, William C.
    MEDICAL PHYSICS, 2011, 38 (02) : 1089 - 1102
  • [38] Noise equivalent count study of pixelated CdZnTe detectors
    Pansky, A.
    Amrami, R.
    Wainer, N.
    Hefetz, Y.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 2 : 1195 - 1198
  • [39] STATISTICAL EVALUATION OF DEAD TIME EFFECTS AND PULSE PILEUP IN FAST PHOTON-COUNTING - INTRODUCTION OF THE SEQUENTIAL MODEL
    WILLIAMSON, JA
    KENDALLTOBIAS, MW
    BUHL, M
    SEIBERT, M
    ANALYTICAL CHEMISTRY, 1988, 60 (20) : 2198 - 2203
  • [40] Maximum count rate of large area superconducting single photon detectors
    Ejrnaes, M.
    Casaburi, A.
    Cristiano, R.
    Quaranta, O.
    Marchetti, S.
    Pagano, S.
    JOURNAL OF MODERN OPTICS, 2009, 56 (2-3) : 390 - 394