Design of a cryogen-free high field dual EPR and DNP probe

被引:7
|
作者
Tagami, Kan [1 ]
Thicklin, Raymond [1 ]
Jain, Sheetal [1 ]
Equbal, Asif [1 ]
Li, Miranda [1 ]
Zens, Toby [3 ]
Siaw, Anthony [3 ]
Han, Songi [1 ,2 ]
机构
[1] Univ Calif, Dept Chem & Biochem, Santa Barbara, CA 93106 USA
[2] Univ Calif Santa Barbara, Dept Chem Engn, Santa Barbara, CA 93106 USA
[3] JEOL USA Inc, 11 Dearborn Rd, Peabody, MA 01960 USA
基金
美国国家科学基金会;
关键词
DNP; EPR; NMR; Cryogenic; DYNAMIC NUCLEAR-POLARIZATION; ELECTRON-PARAMAGNETIC-RESONANCE; SOLID-STATE NMR; ENHANCED NMR; SPECTROMETER; SPECTROSCOPY; PERFORMANCE; VERSATILE; HELIUM; INSTRUMENTATION;
D O I
10.1016/j.jmr.2022.107351
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present the design and construction of a cryogen free, dual electron paramagnetic resonance (EPR) and nuclear magnetic resonance (NMR) probe for novel dynamic nuclear polarization (DNP) experiments and concurrent "in situ" analysis of DNP mechanisms. We focus on the probe design that meets the balance between EPR, NMR, and low temperature performance, while maintaining a high degree of versatility: allowing multi-nuclear NMR detection as well as broadband DNP/EPR excitation/detection. To accomplish high NMR/EPR performance, we implement a novel inductively coupled double resonance NMR circuit (1H-13C) in a solid state probe operating at cryogenic temperatures. The components of the circuit were custom built to provide maximum NMR performance, and the physical layout of this circuit was numerically optimized via magnetic field simulations to allow maximum microwave transmission to the sample for optimal EPR performance. Furthermore this probe is based around a cryogen free gas exchange cryostat and has been designed to allow unlimited experiment times down to 8.5 Kelvin with minimal cost. The affordability of EPR/DNP experiment is an extremely important aspect for broader impact with magnetic resonance measurements. The purpose of this article is to provide as complete information as we have available for others with interest in building a dual DNP/EPR instrument based around a cryogen-free cryostat.(c) 2022 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY license (http:// creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:16
相关论文
共 50 条
  • [21] A method for fast field settling in cryogen-free superconducting magnets for NMR
    Kryukov, Eugeny
    Bugoslavsky, Yury
    Linde, Angel Joaquin Perez
    Holubar, Thomas
    Burgess, Stephen
    Marlow, David
    Good, Jeremy
    SOLID STATE NUCLEAR MAGNETIC RESONANCE, 2020, 109
  • [22] New cryogen-free design for superconducting mini-gap undulators
    Hobl, A
    Kubsky, S
    Dölling, D
    Geisler, A
    Komorowski, P
    Krischel, D
    Klein, U
    Rossmanith, R
    Moser, HO
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) : 1232 - 1235
  • [23] The design of a compact cryogen-free superconducting wavelength shifter for synchrotron radiation
    Hwang, CS
    Chang, PC
    Chang, CH
    Hsiao, FZ
    Chen, CT
    Wang, B
    Juang, T
    Chen, JY
    Wahrer, R
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (01) : 503 - 506
  • [24] Design and construction performance of a compact cryogen-free superconducting wavelength shifter
    Hwang, CS
    Wang, B
    Wahrer, R
    Chen, HH
    Chang, CH
    Lin, FY
    Fan, TC
    Chen, CT
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2002, 12 (01) : 686 - 690
  • [25] Vibration isolation with high thermal conductance for a cryogen-free dilution refrigerator
    de Wit, Martin
    Welker, Gesa
    Heeck, Kier
    Buters, Frank M.
    Eerkens, Hedwig J.
    Koning, Gert
    van der Meer, Harmen
    Bouwmeester, Dirk
    Oosterkamp, Tjerk H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (01):
  • [26] A cryogen-free cryostat for scientific experiment in pulsed high magnetic fields
    Wang, Shaoliang
    Li, Liang
    Zuo, Huakun
    Liu, Mengyu
    Peng, Tao
    PROCEEDINGS OF THE 25TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2014, 2015, 67 : 744 - 749
  • [27] Performance and reproducibility of 13C and 15N hyperpolarization using a cryogen-free DNP polarizer
    Arianna Ferrari
    Josh Peters
    Mariia Anikeeva
    Andrey Pravdivtsev
    Frowin Ellermann
    Kolja Them
    Olga Will
    Eva Peschke
    Hikari Yoshihara
    Olav Jansen
    Jan-Bernd Hövener
    Scientific Reports, 12
  • [28] Hybrid magnets and cryogen-free superconducting magnets developed at the High-Field Laboratory for superconducting materials
    Watanabe, K
    Awaji, S
    Takahashi, K
    Motokawa, M
    PHYSICA B, 2001, 294 : 541 - 546
  • [29] Performance and reproducibility of 13C and 15N hyperpolarization using a cryogen-free DNP polarizer
    Ferrari, Arianna
    Peters, Josh
    Anikeeva, Mariia
    Pravdivtsev, Andrey
    Ellermann, Frowin
    Them, Kolja
    Will, Olga
    Peschke, Eva
    Yoshihara, Hikari
    Jansen, Olav
    Hoevener, Jan-Bernd
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [30] Design of YBCO Insert Coil for a Cryogen-Free 22 T Superconducting Magnet
    Miyazaki, Hiroshi
    Iwai, Sadanori
    Tosaka, Taizo
    Tasaki, Kenji
    Hanai, Satoshi
    Ioka, Shigeru
    Watanabe, Kazuo
    Awaji, Satoshi
    Oguro, Hidetoshi
    Fujita, Shinji
    Daibo, Masanori
    Iijima, Yasuhiro
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2014, 24 (03)