On the battery life of a totally implantable active middle ear device: a retrospective study in a single implanting center

被引:0
|
作者
Barbara, Maurizio [1 ,4 ]
Margani, Valerio [1 ]
Volpini, Luigi [2 ]
Filippi, Chiara [1 ]
Covelli, Edoardo [1 ]
Monini, Simonetta [1 ]
Elfarargy, Haitham H. [3 ]
机构
[1] St Andrea Univ Hosp, Dept Neurosci Mental Hlth & Sensory Organs, Rome, Italy
[2] Liverpool Univ Hosp NHS Fdn Trust, Otorhinolaryngol Dept, Liverpool, England
[3] Kafrelsheikh Univ, Otorhinolaryngol Dept, Kafrelsheikh, Egypt
[4] Sapienza Univ, Med & Psychol Dept, Via Grottarossa 1035-1039, I-00189 Rome, Italy
关键词
Active middle ear device; totally implantable system; esteem system; battery life; battery change surgery; audiometry; bone conduction threshold; ESTEEM; REHABILITATION; EXPERIENCE;
D O I
10.1080/00016489.2022.2161625
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
BackgroundTotally-implantable active middle ear devices (AMED) rely on a non-rechargeable battery encased with the implantable sound processor that needs to be replaced with a minor surgical procedure after its depletion.ObjectivesThis study aimed to investigate the most significant factors affecting the implant's battery life.Materials and MethodsThe implanted subjects (29 patients) were divided into three groups; group A with 17 patients who underwent one battery change surgery; group B with ten patients who underwent two battery changes; and group C with two patients and three surgeries. The battery life was put in correlation with several variables, including daily use and the auditory threshold.ResultsThe battery life ranged from 26 to 67 months, with a mean of 48.93 +/- 13.47. Pearson's correlation coefficient revealed that the battery life was statistically correlated only with the mean post-implantation bone conduction thresholds (p-value <.0001).ConclusionsAlthough the non-rechargeable battery system of the AMED under study overcomes the drawbacks of daily charging, it needs to be surgically changed after its depletion. The different rates of battery life were shown to mainly depend on the post-implantation BC thresholds, which in some cases showed a deterioration concerning the pre-implanting values.
引用
收藏
页码:6 / 11
页数:6
相关论文
共 50 条
  • [31] Analysis of Clinical Efficacy and Quality of Life of Braun Anastomosis in Gastrointestinal Reconstruction in Totally Laparoscopic Distal Gastrectomy: A Single-Center Retrospective Study
    Fu, Yayan
    Ren, Jun
    Ma, Yue
    Zhou, Jiajie
    Shao, Wenzhe
    Sun, Guowei
    Sun, Qiannan
    Wang, Daorong
    JOURNAL OF GASTROINTESTINAL CANCER, 2024, 55 (03) : 1256 - 1265
  • [32] RISK FACTORS FOR DETERIORATION IN ACTIVE TUBERCULOSIS PATIENTS: A RETROSPECTIVE STUDY IN A SINGLE CENTER
    Nabeya, D.
    Kinjo, T.
    Yamashiro, T.
    Parrott, G.
    Yamazato, S.
    Nahar, S.
    Haranaga, S.
    Tateyama, M.
    Fujita, J.
    RESPIROLOGY, 2016, 21 : 197 - 197
  • [33] Long-term Stability of the Active Middle-ear Implant with Floating-mass Transducer Technology: A Single-center Study
    Schraven, Sebastian P.
    Grossmann, Wilma
    Rak, Kristen
    Shehata-Dieler, Wafaa
    Hagen, Rudolf
    Mlynski, Robert
    OTOLOGY & NEUROTOLOGY, 2016, 37 (03) : 252 - 266
  • [34] Phase III clinical trial results with the Vibrant Soundbridge implantable middle ear hearing device: A prospective controlled multicenter study
    Luetje, CM
    Brackman, D
    Balkany, TJ
    Maw, J
    Baker, RS
    Kelsall, D
    Backous, D
    Miyamoto, R
    Parisier, S
    Arts, A
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2002, 126 (02) : 97 - 107
  • [35] Complications after removal of totally implanted central venous access devices: A single-center retrospective study
    Gennequin, Mael
    Elmawieh, Jamie
    Gomas, Frederic
    JOURNAL OF VASCULAR ACCESS, 2024, 25 (04): : 1219 - 1223
  • [36] Transcatheter device closure of ventricular septal defects in children: a retrospective study at a single cardiac center
    Khoshhal, Saad Q.
    Al-Mutairi, Mansour B.
    Alnajjar, Abdulhameed A.
    Morsy, Mohamed M.
    Salem, Sherif S.
    Al-Muhaya, Mustafa
    El-Harbi, Khaled M.
    Abo-Haded, Hany M.
    ANNALS OF SAUDI MEDICINE, 2020, 40 (05) : 396 - 402
  • [37] Single center experience on implementation of the postpartum intrauterine device (PPIUD) in Sri Lanka: a retrospective study
    D. L. W. Dasanayake
    M. Patabendige
    Y. Amarasinghe
    BMC Research Notes, 13
  • [38] The Dual Role of Implantable Loop Recorder in Patients with Potentially Arrhythmic Symptoms: A Retrospective Single-Center Study
    Kabra, Rajesh
    Gopinathannair, Rakesh
    Sandesara, Chirag
    Messinger, Catherine
    Olshansky, Brian
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (07): : 908 - 912
  • [39] Single center experience on implementation of the postpartum intrauterine device (PPIUD) in Sri Lanka: a retrospective study
    Dasanayake, D. L. W.
    Patabendige, M.
    Amarasinghe, Y.
    BMC RESEARCH NOTES, 2020, 13 (01)
  • [40] Pipeline Embolization Device for Pericallosal Artery Aneurysms: A Retrospective Single Center Safety and Efficacy Study
    Rodrigues, Katyucia De Macedo
    Kuhn, Anna Luisa
    Tamura, Takamitsu
    Dabus, Guilherme
    Kan, Peter
    Marosfoi, Miklos G.
    Lozano, J. Diego
    Perras, Mary
    Brooks, Christopher
    Howk, Mary C.
    Hou, Samuel Y.
    Rex, David E.
    Massari, Francesco
    Gounis, Matthew J.
    Wakhloo, Ajay K.
    Puri, Ajit S.
    OPERATIVE NEUROSURGERY, 2018, 14 (04) : 351 - 358