Effect of reversely-variable circuitry on finned-tube heat exchanger performance in air source heat pump under annual performance factor (APF) conditions

被引:2
|
作者
Zhao, Rijing [1 ]
Sun, Yu [1 ]
Wang, Fei [1 ,2 ]
Qi, Zhaoqian [2 ]
Huang, Dong [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, 28 Xianning West Rd, Xian 710049, Peoples R China
[2] Qingdao Haier Air Conditioner Gen Corp Ltd, 1 Haier Rd, Qingdao 266103, Peoples R China
基金
中国国家自然科学基金;
关键词
Finned-tube heat exchanger; Air-source heat pump; Reversely-variable circuitry; Operating condition; REFRIGERANT CIRCUITRY; PRESSURE-DROP; 2-PHASE FLOW; EVAPORATOR; OPTIMIZATION; IMPROVEMENT; EXERGY;
D O I
10.1016/j.ijrefrig.2022.09.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
The finned-tube heat exchanger (FTHX) in air-source heat pumps (ASHPs) shows a contradiction that the evaporator prefers more circuits while the condenser likes fewer. Hence, the reversely-variable circuity is pro-posed in our previous work to address this problem by incorporating the respective optimal circuits for the FTHX in both modes. In this article, the reversely-variable circuitry is adopted to maintain 7 circuits in the evaporator mode but 4-2-1 flowpath (4 circuits merging into 2 then 1) in the condenser mode of the outdoor FTHX. Compared with the original 7-circuit reversely-fixed one, the reversely-variable FTHX yields 2.1% higher annual performance factor (APF) for the ASHP due to higher capacity and COP in all 6 cooling conditions, when the outdoor FTHX is used as the condenser and the fewer circuits increases the overall heat transfer coefficient. Moreover, the performance enhancement with the reversely-variable FTHX is higher in lower-temperature ambience and part load conditions, since refrigerant flowrate is lower and the increment in overall heat trans-fer coefficient is more dominant. Different possible transformations of the reversely-variable circuitry is obtained with the principles of single-way valves and distributors described, so that it could be popularized to wider applications.
引用
收藏
页码:28 / 39
页数:12
相关论文
共 50 条
  • [41] Effect of circuit arrangement on the performance of plate finned tube heat exchangers under dehumidifying conditions
    Liu, Min-Sheng
    Leu, Jin-Sheng
    Wang, Chi-Chuan
    Mei, Vince C.
    American Society of Mechanical Engineers, Advanced Energy Systems Division (Publication) AES, 1999, 39 : 627 - 633
  • [42] Numerical investigation to analyse the effect of fin shape on performance of finned tube heat exchanger
    Shah, M.
    Shah, R.
    JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2022, 16 (03) : 9014 - 9024
  • [43] PERFORMANCE OF FINNED-TUBE HEAT-EXCHANGERS UNDER FROSTING CONDITIONS .2. COMPARISON OF EXPERIMENTAL-DATA WITH MODEL
    KONDEPUDI, SN
    ONEAL, DL
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1993, 16 (03): : 181 - 184
  • [44] Experimental Study on Heat Transfer and Resistance Performance of Elliptical Finned Tube Heat Exchanger with Different Air Entrance Angles
    Du, Xueping
    Zeng, Min
    Wang, Qiuwang
    Dong, Zhaoyi
    PRES 2011: 14TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1 AND 2, 2011, 25 : 369 - +
  • [45] Influence of Different Baffle Structures on Heat Transfer Performance of Shell and Tube Heat Exchanger for Seawater Source Heat Pump
    Zhang, Guanzheng
    Li, Baohua
    Dai, YuanJun
    2022 IEEE 13TH INTERNATIONAL CONFERENCE ON MECHANICAL AND INTELLIGENT MANUFACTURING TECHNOLOGIES (ICMIMT 2022), 2022, : 221 - 225
  • [46] Enhancement of thermal and hydraulic performance of compact finned-tube heat exchanger using vortex generators (VGs): A parametric study
    Awais, Muhammad
    Bhuiyan, Arafat A.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 140 : 154 - 166
  • [47] Numerical investigation and experimental validation of the thermal performance enhancement of a compact finned-tube heat exchanger for efficient latent heat thermal energy storage
    Amagour, Mohamed El Habib
    Bennajah, Mounir
    Rachek, Adil
    JOURNAL OF CLEANER PRODUCTION, 2021, 280
  • [48] AN EXPERIMENTAL STUDY ON PERFORMANCE IMPROVEMENT FOR AN AIR SOURCE HEAT PUMP BY ALTERNATE DEFROSTING OF OUTDOOR HEAT EXCHANGER
    Jung, Hoon
    Hwang, Jungho
    Jeon, Changduk
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2014, 22 (03)
  • [49] Investigation of annual energy performance of a VWV air source heat pump system
    Wang, R. Z.
    Jin, Z. Q.
    Zhai, X. Q.
    Jin, C. C.
    Luo, W. L.
    Eikevik, T. M.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 85 : 383 - 394
  • [50] Model development and performance investigation of staggered tube-bundle heat exchanger for seawater source heat pump
    Wu, Zhenjing
    You, Shijun
    Zhang, Huan
    Zheng, Wandong
    APPLIED ENERGY, 2020, 262 (262)