Seismic Retrofit of Nonuniformly Corroded Coastal Bridge Piers with FRP and Engineered Cementitious Composite Overlays

被引:6
|
作者
Zhou, Yingwu [1 ]
Wang, Xiaohan [1 ]
Hu, Biao [1 ]
Sui, Lili [1 ]
Yuan, Fang [1 ]
机构
[1] Shenzhen Univ, Guangdong Prov Key Lab Durabil Marine Civil Engn, Shenzhen 518060, Peoples R China
基金
中国国家自然科学基金;
关键词
Corrosion; Coastal bridge pier; Splash and tidal zone; Fiber-reinforced polymer (FRP); Engineered cementitious composite (ECC); Seismic behavior; REINFORCED-CONCRETE COLUMNS; PLASTIC HINGE; SULFATE ATTACK; CORROSION; BEHAVIOR; BOND; PERFORMANCE; CRACKING; BAR;
D O I
10.1061/JCCOF2.CCENG-3993
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Coastal bridge piers are prone to corrosion attack owing to their exposure to marine environments, particularly in the splash and tidal zone, which is rich in chloride, oxygen, and moisture. Severe corrosion in this area results in the transfer of plastic hinges and evidently impairs the structural performance under seismic loading. Previous seismic retrofitting typically focused on the area of the pier end with the greatest bending moment. However, the location of the splash and tidal zone varies with the change in season and is generally not in the pier end. This study investigated for the first time the seismic retrofit of such piers using fiber-reinforced polymer (FRP) and engineered cementitious composite (ECC), where the middle part of the pier subjected to NaCl solution corrosion was simulated as the splash and tidal zone. Reversed cyclic loading tests of nine bridge piers with various corrosion rates, FRP types, and retrofit areas were performed. The seismic behaviors in terms of failure mode, crack pattern, load-carrying capacity, ductility, energy dissipation capacity, and stiffness degradation were compared and discussed. The experimental results of mildly corroded specimens indicated that seismic retrofitting with combined FRP and ECC significantly improved the seismic performance of bridge piers. The retrofitted specimen exhibited an even higher ductility and energy dissipation capacity than the noncorroded specimen. For severely corroded piers, the plastic hinge was transferred from the pier end to the corroded area and then transferred back to the pier end after retrofitting. The seismic performance of the specimens retrofitted from the corroded area to the foundation was better than that of the piers retrofitted only in the corroded area.
引用
下载
收藏
页数:16
相关论文
共 50 条
  • [41] Field application of FRP's in seismic retrofit of a 16-span bridge with flared columns
    Saiidi, MS
    Mangoba, N
    ADVANCED COMPOSITE MATERIALS IN BRIDGES AND STRUCTURES, 2000, : 299 - 306
  • [42] Seismic evaluation and retrofit with steel jackets of reinforced concrete bridge piers detailed with lap-splices
    Daudey, X
    Filiatrault, A
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2000, 27 (01) : 1 - 16
  • [43] Deflection of reinforced concrete beams strengthened with FRP grid-engineered cementitious composite matrix composite
    Deng L.
    Yang Z.
    Zhong M.
    Lei L.
    Liao L.
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2023, 40 (09): : 5212 - 5224
  • [44] Bond behavior and modeling of steel-FRP composite bars in engineered cementitious composites
    Bai, Yulei
    Ma, Qipeng
    Zhang, Yufeng
    Jin, Xiaojie
    Han, Shiwen
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 20
  • [45] Seismic behaviors of steel-FRP composite bar-reinforced engineered cementitious composites columns under reversed cyclic loads
    Xu, Li
    Wang, Xiaoyi
    Dong, Bingqing
    Yang, Xiao
    Pan, Jinlong
    ENGINEERING STRUCTURES, 2024, 316
  • [46] Time-Dependent Seismic Reliability of Coastal Bridge Piers Subjected to Nonuniform Corrosion
    Yuan, Wenting
    Wu, Xiangtong
    Wang, Yuren
    Liu, Zhenliang
    Zhou, Peng
    MATERIALS, 2023, 16 (03)
  • [47] Cross-shaped bidirectional quasi-static tests and damage analysis of corroded coastal bridge piers
    Yuan W.-T.
    Qi Y.-J.
    Fang Q.-H.
    Gongcheng Lixue/Engineering Mechanics, 2022, 39 (03): : 115 - 125
  • [48] SEISMIC PERFORMANCE AND RETROFIT EVALUATION OF HOLLOW-CORE COMPOSITE BRIDGE COLUMNS
    Abdulazeez, Mohanad M.
    Gheni, Ahmed
    Colbert, Nicholas
    ElGawady, Mohamed A.
    MAINTENANCE, SAFETY, RISK, MANAGEMENT AND LIFE-CYCLE PERFORMANCE OF BRIDGES, 2018, : 437 - 444
  • [49] Performance of bridge deck link slabs designed with ductile engineered cementitious composite
    Kim, YY
    Fischer, G
    Li, VC
    ACI STRUCTURAL JOURNAL, 2004, 101 (06) : 792 - 801
  • [50] Experimental evaluation of seismic performance of corroded precast RC bridge columns and the retrofit measure using CFRP jackets
    Wang, Xu
    Wu, Suiwen
    Jia, Junfeng
    Li, Huaqiang
    Wei, Yanjian
    Zhang, Kaidi
    Bai, Yulei
    ENGINEERING STRUCTURES, 2021, 245