Seismic Retrofit of Nonuniformly Corroded Coastal Bridge Piers with FRP and Engineered Cementitious Composite Overlays

被引:6
|
作者
Zhou, Yingwu [1 ]
Wang, Xiaohan [1 ]
Hu, Biao [1 ]
Sui, Lili [1 ]
Yuan, Fang [1 ]
机构
[1] Shenzhen Univ, Guangdong Prov Key Lab Durabil Marine Civil Engn, Shenzhen 518060, Peoples R China
基金
中国国家自然科学基金;
关键词
Corrosion; Coastal bridge pier; Splash and tidal zone; Fiber-reinforced polymer (FRP); Engineered cementitious composite (ECC); Seismic behavior; REINFORCED-CONCRETE COLUMNS; PLASTIC HINGE; SULFATE ATTACK; CORROSION; BEHAVIOR; BOND; PERFORMANCE; CRACKING; BAR;
D O I
10.1061/JCCOF2.CCENG-3993
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Coastal bridge piers are prone to corrosion attack owing to their exposure to marine environments, particularly in the splash and tidal zone, which is rich in chloride, oxygen, and moisture. Severe corrosion in this area results in the transfer of plastic hinges and evidently impairs the structural performance under seismic loading. Previous seismic retrofitting typically focused on the area of the pier end with the greatest bending moment. However, the location of the splash and tidal zone varies with the change in season and is generally not in the pier end. This study investigated for the first time the seismic retrofit of such piers using fiber-reinforced polymer (FRP) and engineered cementitious composite (ECC), where the middle part of the pier subjected to NaCl solution corrosion was simulated as the splash and tidal zone. Reversed cyclic loading tests of nine bridge piers with various corrosion rates, FRP types, and retrofit areas were performed. The seismic behaviors in terms of failure mode, crack pattern, load-carrying capacity, ductility, energy dissipation capacity, and stiffness degradation were compared and discussed. The experimental results of mildly corroded specimens indicated that seismic retrofitting with combined FRP and ECC significantly improved the seismic performance of bridge piers. The retrofitted specimen exhibited an even higher ductility and energy dissipation capacity than the noncorroded specimen. For severely corroded piers, the plastic hinge was transferred from the pier end to the corroded area and then transferred back to the pier end after retrofitting. The seismic performance of the specimens retrofitted from the corroded area to the foundation was better than that of the piers retrofitted only in the corroded area.
引用
下载
收藏
页数:16
相关论文
共 50 条
  • [1] FRP seismic retrofit of RC square hollow section bridge piers
    Pavese, A
    Bolognini, D
    Peloso, S
    JOURNAL OF EARTHQUAKE ENGINEERING, 2004, 8 : 225 - 250
  • [2] Seismic performance of corroded concrete bridge piers
    Fang, Congqi
    Yuan, Zhijie
    Yang, Shuai
    Zhang, Junmeng
    MAINTENANCE, MONITORING, SAFETY, RISK AND RESILIENCE OF BRIDGES AND BRIDGE NETWORKS, 2016, : 420 - 420
  • [3] Experimental Investigation on Seismic Behavior of Bridge Piers with Polypropylene-engineered Cementitious Composite in Plastic Hinge Regions
    Jia Y.
    Zhao R.-D.
    Liao P.
    Li F.-H.
    Zhan Y.-L.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2019, 32 (07): : 100 - 110
  • [4] Seismic performance of reinforced corroded concrete bridge piers
    Fang, C. Q.
    Yuan, Z. J.
    Zhang, J. M.
    Zhu, J.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT AND LIFE EXTENSION, 2014, : 253 - 260
  • [5] Experimental investigation of seismic behaviour of corroded RC bridge piers
    Ge, X.
    Alexander, N. A.
    Kashani, M. M.
    LIFE-CYCLE ANALYSIS AND ASSESSMENT IN CIVIL ENGINEERING: TOWARDS AN INTEGRATED VISION, 2019, : 2775 - 2782
  • [6] Seismic retrofit of plain concrete piers of railroad bridges using composite of FRP-steel plates
    Choi, Eunsoo
    Rhee, Inkyu
    Park, Joonam
    Cho, Baik-Soon
    COMPOSITES PART B-ENGINEERING, 2011, 42 (05) : 1097 - 1107
  • [7] Analysis of seismic performance of corroded reinforced concrete bridge piers
    Fang, Congqi
    Yuan, Zhijie
    Yang, Shuai
    Zhang, Junmeng
    MAINTENANCE, MONITORING, SAFETY, RISK AND RESILIENCE OF BRIDGES AND BRIDGE NETWORKS, 2016, : 515 - 515
  • [8] Feasibility Study of Using Engineered Cementitious Composite and High-Strength Bars in Rigid Bridge Piers Based on Seismic Vulnerability Analysis
    Li, Jie
    Hu, Yuanhong
    Yang, Dayu
    Feng, Tengda
    Liang, Yan
    Tao, Chenchen
    SHOCK AND VIBRATION, 2020, 2020
  • [9] Replacement bridge piers for seismic retrofit under traffic service
    Ogata, Tatsuo
    Kakiuchi, Norio
    Kuwahara, Hideaki
    Shikuma, Takeshi
    Takada, Koshiro
    Aoyama, Tomoaki
    MAINTENANCE, MONITORING, SAFETY, RISK AND RESILIENCE OF BRIDGES AND BRIDGE NETWORKS, 2016, : 528 - 528
  • [10] Seismic performance of hollow-bridge piers repaired by FRP
    Cheng, CT
    Yang, JC
    Yeh, YK
    FRP COMPOSITES IN CIVIL ENGINEERING, VOLS I AND II, PROCEEDINGS, 2001, : 859 - 867