Automated antibody dispensing to improve high-parameter flow cytometry throughput and analysis

被引:1
|
作者
Bosteels, Victor [1 ,2 ]
Van Duyse, Julie [3 ,4 ]
Ruyssinck, Elien [3 ,4 ]
Van der Borght, Katrien [3 ,4 ]
Nguyen, Long [5 ,6 ]
Gavel, Jannes [1 ,7 ]
Janssens, Sophie [1 ,2 ]
Van Isterdael, Gert [3 ,4 ]
机构
[1] Univ Ghent, Dept Internal Med & Pediat, Ghent, Belgium
[2] VIB Ctr Inflammat Res, Lab ER Stress & Inflammat, Ghent, Belgium
[3] Univ Ghent, Dept Biomed Mol Biol, Ghent, Belgium
[4] VIB Ctr Inflammat Res, VIB Flow Core, Ghent, Belgium
[5] VIB Screening Core VIB, Ghent, Belgium
[6] Univ Ghent, Ctr Bioassay Dev & Screening, Ghent, Belgium
[7] VIB Ctr Inflammat Res, Immunoregulat & Mucosal Immunol Lab, Ghent, Belgium
关键词
antibody pipetting; automation; high-parameter flow cytometry; I.DOT; VISUALIZATION;
D O I
10.1002/cyto.a.24835
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the past decade, the flow cytometry field has witnessed significant advancements in the number of fluorochromes that can be detected. This enables researchers to analyze more than 40 markers simultaneously on thousands of cells per second. However, with this increased complexity and multiplicity of markers, the manual dispensing of antibodies for flow cytometry experiments has become laborious, time-consuming, and prone to errors. An automated antibody dispensing system could provide a potential solution by enhancing the efficiency, and by improving data quality by faithfully dispensing the fluorochrome-conjugated antibodies and by enabling the easy addition of extra controls. In this study, a comprehensive comparison of different liquid handlers for dispensing fluorochrome-labeled antibodies was conducted for the preparation of flow cytometry stainings. The evaluation focused on key criteria including dispensing time, dead volume, and reliability of dispensing. After benchmarking, the I.DOT, a non-contact liquid handler, was selected and optimized in more detail. In the end, the I.DOT was able to prepare a 25-marker panel in 20 min, including the full stain, all FMOs and all single stain controls for cells and beads. Having all these controls improved the validation of the panel, visualization, and analysis of the data. Thus, automated antibody dispensing by dispensers such as the I.DOT reduces time and errors, enhances data quality, and can be easily integrated in an automated workflow to prepare samples for flow cytometry.
引用
收藏
页码:464 / 473
页数:10
相关论文
共 50 条
  • [21] Extending the capabilities of a high-parameter immunophenotyping assay with cytoplasmic staining applications for mass cytometry
    Saederup, Noah
    Yao, Huihui
    Cohen, Michael
    Fung, Leslie
    [J]. CANCER RESEARCH, 2022, 82 (12)
  • [22] Computational analysis of high-throughput flow cytometry data
    Robinson, J. Paul
    Rajwa, Bartek
    Patsekin, Valery
    Davisson, Vincent Jo
    [J]. EXPERT OPINION ON DRUG DISCOVERY, 2012, 7 (08) : 679 - 693
  • [23] High Throughput Analysis of Golgi Structure by Imaging Flow Cytometry
    Inbal Wortzel
    Gabriela Koifman
    Varda Rotter
    Rony Seger
    Ziv Porat
    [J]. Scientific Reports, 7
  • [24] Automated analysis in flow cytometry
    Cualing, HD
    [J]. CYTOMETRY, 2000, 42 (02): : 110 - 113
  • [25] HTPS flow cytometry: A novel platform for automated high throughput drug discovery and characterization
    Edwards, BS
    Kuckuck, FW
    Prossnitz, ER
    Ransom, JT
    Sklar, LA
    [J]. JOURNAL OF BIOMOLECULAR SCREENING, 2001, 6 (02) : 83 - 90
  • [26] Extending the capabilities of a high-parameter immunophenotyping assay with cytoplasmic staining applications for mass cytometry
    Rogers, Clare E.
    Yao, Huihui
    Cohen, Michael
    Loh, Christina
    [J]. JOURNAL OF IMMUNOLOGY, 2022, 208 (01):
  • [27] High-throughput Cytometry Using Antibody Arrays
    Kato, Koichi
    Ko, In-Kap
    Ishimuro, Toshinari
    Toda, Mitsuaki
    Arima, Yusuke
    Hirata, Isao
    Iwata, Hiroo
    [J]. BIOMATERIALS IN ASIA: IN COMMEMORATION OF THE 1ST ASIAN BIOMATERIALS CONGRESS, 2008, : 506 - 516
  • [28] Flow cytometry analysis techniques for high-throughput biodefense research
    Jett, JH
    Cai, H
    Habbersett, RC
    Keller, RA
    Larson, EJ
    Marrone, BL
    Nolan, JP
    Song, XD
    Swanson, B
    White, PS
    [J]. FIREPOWER IN THE LAB: AUTOMATION IN THE FIGHT AGAINST INFECTIOUS DISEASES AND BIOTERRORISM, 2001, : 193 - 201
  • [29] Development and validation of a high-parameter mass cytometry workflow to decipher immunomodulatory changes in celiac disease
    Estevam, Jose
    Krutzik, Peter
    Vander Tuig, Jason
    McAuliffe, William J.
    Smithson, Glennda
    [J]. CYTOMETRY PART B-CLINICAL CYTOMETRY, 2021, 100 (01) : 92 - 102
  • [30] Dynamic characterization of growth and gene expression using high-throughput automated flow cytometry
    Ignacio A Zuleta
    Andrés Aranda-Díaz
    Hao Li
    Hana El-Samad
    [J]. Nature Methods, 2014, 11 : 443 - 448