Automated antibody dispensing to improve high-parameter flow cytometry throughput and analysis

被引:1
|
作者
Bosteels, Victor [1 ,2 ]
Van Duyse, Julie [3 ,4 ]
Ruyssinck, Elien [3 ,4 ]
Van der Borght, Katrien [3 ,4 ]
Nguyen, Long [5 ,6 ]
Gavel, Jannes [1 ,7 ]
Janssens, Sophie [1 ,2 ]
Van Isterdael, Gert [3 ,4 ]
机构
[1] Univ Ghent, Dept Internal Med & Pediat, Ghent, Belgium
[2] VIB Ctr Inflammat Res, Lab ER Stress & Inflammat, Ghent, Belgium
[3] Univ Ghent, Dept Biomed Mol Biol, Ghent, Belgium
[4] VIB Ctr Inflammat Res, VIB Flow Core, Ghent, Belgium
[5] VIB Screening Core VIB, Ghent, Belgium
[6] Univ Ghent, Ctr Bioassay Dev & Screening, Ghent, Belgium
[7] VIB Ctr Inflammat Res, Immunoregulat & Mucosal Immunol Lab, Ghent, Belgium
关键词
antibody pipetting; automation; high-parameter flow cytometry; I.DOT; VISUALIZATION;
D O I
10.1002/cyto.a.24835
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the past decade, the flow cytometry field has witnessed significant advancements in the number of fluorochromes that can be detected. This enables researchers to analyze more than 40 markers simultaneously on thousands of cells per second. However, with this increased complexity and multiplicity of markers, the manual dispensing of antibodies for flow cytometry experiments has become laborious, time-consuming, and prone to errors. An automated antibody dispensing system could provide a potential solution by enhancing the efficiency, and by improving data quality by faithfully dispensing the fluorochrome-conjugated antibodies and by enabling the easy addition of extra controls. In this study, a comprehensive comparison of different liquid handlers for dispensing fluorochrome-labeled antibodies was conducted for the preparation of flow cytometry stainings. The evaluation focused on key criteria including dispensing time, dead volume, and reliability of dispensing. After benchmarking, the I.DOT, a non-contact liquid handler, was selected and optimized in more detail. In the end, the I.DOT was able to prepare a 25-marker panel in 20 min, including the full stain, all FMOs and all single stain controls for cells and beads. Having all these controls improved the validation of the panel, visualization, and analysis of the data. Thus, automated antibody dispensing by dispensers such as the I.DOT reduces time and errors, enhances data quality, and can be easily integrated in an automated workflow to prepare samples for flow cytometry.
引用
收藏
页码:464 / 473
页数:10
相关论文
共 50 条
  • [1] Combinatorial antibody titrations for high-parameter flow cytometry
    Burn, Olivia K.
    Mair, Florian
    Ferrer-Font, Laura
    [J]. CYTOMETRY PART A, 2024, 105 (05) : 388 - 393
  • [2] High throughput automated analysis of big flow cytometry data
    Rahim, Albina
    Meskas, Justin
    Drissler, Sibyl
    Yue, Alice
    Lorenc, Anna
    Laing, Adam
    Saran, Namita
    White, Jacqui
    Abeler-Dorner, Lucie
    Hayday, Adrian
    Brinkman, Ryan R.
    [J]. METHODS, 2018, 134 : 164 - 176
  • [3] Automated High-Throughput Flow Cytometry for High-Content Screening in Antibody Development
    Wang, Yana
    Yoshihara, Tomoki
    King, Samson
    Tinh Le
    Leroy, Patrick
    Zhao, Xiansi
    Chan, Ching Kit
    Yan, Zhong-Hua
    Menon, Saurabh
    [J]. SLAS DISCOVERY, 2018, 23 (07) : 656 - 666
  • [4] Optimizing transformations for automated, high throughput analysis of flow cytometry data
    Finak, Greg
    Perez, Juan-Manuel
    Weng, Andrew
    Gottardo, Raphael
    [J]. BMC BIOINFORMATICS, 2010, 11
  • [5] Optimizing transformations for automated, high throughput analysis of flow cytometry data
    Greg Finak
    Juan-Manuel Perez
    Andrew Weng
    Raphael Gottardo
    [J]. BMC Bioinformatics, 11
  • [6] OMIP-097: High-parameter phenotyping of human platelets by spectral flow cytometry
    Spurgeon, Benjamin E. J.
    Frelinger III, Andrew L.
    [J]. CYTOMETRY PART A, 2023, 103 (12) : 935 - 940
  • [7] Setting the gold standard: Commentary on designing and optimizing high-parameter flow cytometry panels
    De Rosa, Stephen C.
    Mahnke, Yolanda D.
    [J]. CYTOMETRY PART A, 2024, 105 (06) : 428 - 429
  • [8] High-Throughput Analysis of Clinical Flow Cytometry Data by Automated Gating
    Lee, Hunjoong
    Sun, Yongliang
    Patti-Diaz, Lisa
    Hedrick, Michael
    Ehrhardt, Anka G.
    [J]. BIOINFORMATICS AND BIOLOGY INSIGHTS, 2019, 13
  • [9] Studying the cellular basis of small bowel enteropathy using high-parameter flow cytometry in mouse models of primary antibody deficiency
    Mohammed, Ahmed D.
    Ball, Ryan A. W.
    Jolly, Amy
    Nagarkatti, Prakash
    Nagarkatti, Mitzi
    Kubinak, Jason L.
    [J]. FRONTIERS IN IMMUNOLOGY, 2024, 15
  • [10] Single Cell Analysis of High-Parameter Histology Images Using Histoflow Cytometry
    Jain, Rajiv W.
    Elliott, David A.
    Yong, V. Wee
    [J]. JOURNAL OF IMMUNOLOGY, 2023, 210 (12): : 2038 - 2049