The diagnostic performance of endobronchial ultrasound with Xpert MTB/RIF Ultra in smear-negative pulmonary tuberculosis

被引:7
|
作者
Yao, Lan [1 ]
Chen, Shanhao [1 ]
Sha, Wei [1 ]
Gu, Ye [2 ]
机构
[1] Tongji Univ Sch Med, Shanghai Pulm Hosp, Clin & Res Ctr TB, Shanghai Key Lab TB, Shanghai 200433, Peoples R China
[2] Tongji Univ Sch Med, Shanghai Pulm Hosp, Dept Bronchoscopy, Shanghai 200433, Peoples R China
关键词
Pulmonary tuberculosis; Smear-negative; Bronchoscopy; Xpert MTB; RIF Ultra; TRANSBRONCHIAL NEEDLE ASPIRATION; EBUS-TBNA; PLEURAL BIOPSY; YIELD;
D O I
10.1186/s12879-023-08073-7
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
ObjectiveThis study investigated the diagnostic performance of endobronchial ultrasound with Xpert MTB/RIF Ultra (Ultra) for detecting smear-negative pulmonary tuberculosis (TB).Methods143 patients suspected of sputum smear-negative pulmonary tuberculosis were enrolled in this study in Shanghai Pulmonary Hospital, China. These patients underwent endobronchial ultrasound with a guide sheath (EBUS-GS) or endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) based on their chest CT manifestations. We assessed the sensitivity and specificity of tissue specimens with Ultra in the TB group and non-TB group. Culture and clinical diagnosis were used as gold-standard for TB.ResultsAmong these 143 patients, 11 patients were culture-positive TB, 85 patients were diagnosed with culture-negative TB and 47 were with the non-TB diseases. Direct testing with microscopy (Acid-Fast Bacilli smear, AFB), liquid culture, pathology, Xpert MTB/RIF(Xpert) test and Ultra had a sensitivity of 8.3%, 11.5%, 42.7%, 64.6%, and 78.1% individually among all the TB patients. Ultra had a higher sensitivity than Xpert (P = 0.011). But Ultra had a specificity of 59.6% (95% CI 44.3-73.3), lower than that of Xpert (89.4%, 95% CI 76.1-96.0, P = 0.001). Ultra had the same sensitivity on specimens from EBUS-TBNA and EBUS-GS (P = 0.975). Ultra's positive predictive value and negative predictive value were 79.8% and 57.1% respectively.ConclusionsTissue specimens from interventional bronchoscopy combined with Ultra provide a sensitive method for diagnosing smear-negative pulmonary tuberculosis, but its specificity was lower than Xpert.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Rapid detection of Mycobacterium tuberculosis and rifampicin resistance in extrapulmonary tuberculosis and sputum smear-negative pulmonary suspects using Xpert MTB/RIF
    Ullah, Irfan
    Javaid, Arshad
    Masud, Haleema
    Ali, Mazhar
    Basit, Anila
    Ahmad, Waqas
    Younis, Faisal
    Yasmin, Rehana
    Khan, Afsar
    Jabbar, Abdul
    Husain, Masroor
    Butt, Zahid Ahmad
    JOURNAL OF MEDICAL MICROBIOLOGY, 2017, 66 (04) : 412 - 418
  • [22] Diagnostic performance of GeneXpert MTB/RIF in detecting MTB in smear-negative presumptive TB patients
    Rimal, Raksha
    Shrestha, Dhiraj
    Pyakurel, Susil
    Poudel, Rashmi
    Shrestha, Prasha
    Rai, Kul Raj
    Ghimire, Gokarna Raj
    Rai, Ganesh
    Rai, Shiba Kumar
    BMC INFECTIOUS DISEASES, 2022, 22 (01)
  • [23] Diagnostic performance of GeneXpert MTB/RIF in detecting MTB in smear-negative presumptive TB patients
    Raksha Rimal
    Dhiraj Shrestha
    Susil Pyakurel
    Rashmi Poudel
    Prasha Shrestha
    Kul Raj Rai
    Gokarna Raj Ghimire
    Ganesh Rai
    Shiba Kumar Rai
    BMC Infectious Diseases, 22
  • [24] Xpert Mtb/rif Assay In Bronchalveolar Lavage Specimen In Smear Negative Pulmonary Tuberculosis
    Bhattacharyya, D.
    Kumar, M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [25] Infectiousness of patients with smear-negative pulmonary tuberculosis, assessed by Real-time Polymerase Chain Reaction, Xpert® MTB/RIF
    Camprubi, Daniel
    Gomila, Aina
    Grijota-Camino, Maria D.
    Soldevila, Laura
    Luque, Maria J.
    Alcaide, Fernando
    Dorca, Jordi
    Santin, Miguel
    JOURNAL OF INFECTION, 2020, 80 (03) : 298 - 300
  • [26] Diagnostic value of Xpert MTB / RIF in pulmonary tuberculosis
    Feng, Xiuli
    Ren, Xinxin
    Cui, Dan
    Liu, Pengchong
    Li, Na
    Cao, Yanlun
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2021, 128 : 128 - 128
  • [27] Sputum quality and diagnostic performance of GeneXpert MTB/RIF among smear-negative adults with presumed tuberculosis in Uganda
    Meyer, Amanda J.
    Atuheire, Collins
    Worodria, William
    Kizito, Samuel
    Katamba, Achilles
    Sanyu, Ingvar
    Andama, Alfred
    Ayakaka, Irene
    Cattamanchi, Adithya
    Bwanga, Freddie
    Huang, Laurence
    Davis, J. Lucian
    PLOS ONE, 2017, 12 (07):
  • [28] Application of CBNAAT (Xpert MTB/RIF assay) in new smear negative pulmonary tuberculosis patients
    Chopra, Vishal
    Virk, Baljeet Singh
    Chopra, Siddharth
    Bansal, Monika
    Chungath, Jain
    MONALDI ARCHIVES FOR CHEST DISEASE, 2020, 90 (01) : 105 - 109
  • [29] DIAGNOSTIC TEST OF SPUTUM GENEXPERT MTB/RIF FOR SMEAR NEGATIVE PULMONARY TUBERCULOSIS
    Reechaipichitkul, Wipa
    Phetsuriyawong, Attawoot
    Chaimanee, Prajuab
    Ananta, Pimjai
    SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2016, 47 (03) : 457 - 466
  • [30] The transition to Xpert MTB/RIF ultra: diagnostic accuracy for pulmonary tuberculosis in Kampala, Uganda
    A. Andama
    D. Jaganath
    R. Crowder
    L. Asege
    M. Nakaye
    D. Katumba
    J. Mukwatamundu
    S. Mwebe
    C. F. Semitala
    W. Worodria
    M. Joloba
    S. Mohanty
    A. Somoskovi
    A. Cattamanchi
    BMC Infectious Diseases, 21