The diagnostic performance of endobronchial ultrasound with Xpert MTB/RIF Ultra in smear-negative pulmonary tuberculosis

被引:7
|
作者
Yao, Lan [1 ]
Chen, Shanhao [1 ]
Sha, Wei [1 ]
Gu, Ye [2 ]
机构
[1] Tongji Univ Sch Med, Shanghai Pulm Hosp, Clin & Res Ctr TB, Shanghai Key Lab TB, Shanghai 200433, Peoples R China
[2] Tongji Univ Sch Med, Shanghai Pulm Hosp, Dept Bronchoscopy, Shanghai 200433, Peoples R China
关键词
Pulmonary tuberculosis; Smear-negative; Bronchoscopy; Xpert MTB; RIF Ultra; TRANSBRONCHIAL NEEDLE ASPIRATION; EBUS-TBNA; PLEURAL BIOPSY; YIELD;
D O I
10.1186/s12879-023-08073-7
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
ObjectiveThis study investigated the diagnostic performance of endobronchial ultrasound with Xpert MTB/RIF Ultra (Ultra) for detecting smear-negative pulmonary tuberculosis (TB).Methods143 patients suspected of sputum smear-negative pulmonary tuberculosis were enrolled in this study in Shanghai Pulmonary Hospital, China. These patients underwent endobronchial ultrasound with a guide sheath (EBUS-GS) or endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) based on their chest CT manifestations. We assessed the sensitivity and specificity of tissue specimens with Ultra in the TB group and non-TB group. Culture and clinical diagnosis were used as gold-standard for TB.ResultsAmong these 143 patients, 11 patients were culture-positive TB, 85 patients were diagnosed with culture-negative TB and 47 were with the non-TB diseases. Direct testing with microscopy (Acid-Fast Bacilli smear, AFB), liquid culture, pathology, Xpert MTB/RIF(Xpert) test and Ultra had a sensitivity of 8.3%, 11.5%, 42.7%, 64.6%, and 78.1% individually among all the TB patients. Ultra had a higher sensitivity than Xpert (P = 0.011). But Ultra had a specificity of 59.6% (95% CI 44.3-73.3), lower than that of Xpert (89.4%, 95% CI 76.1-96.0, P = 0.001). Ultra had the same sensitivity on specimens from EBUS-TBNA and EBUS-GS (P = 0.975). Ultra's positive predictive value and negative predictive value were 79.8% and 57.1% respectively.ConclusionsTissue specimens from interventional bronchoscopy combined with Ultra provide a sensitive method for diagnosing smear-negative pulmonary tuberculosis, but its specificity was lower than Xpert.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] The diagnostic performance of endobronchial ultrasound with Xpert MTB/RIF Ultra in smear-negative pulmonary tuberculosis
    Lan Yao
    Shanhao Chen
    Wei Sha
    Ye Gu
    BMC Infectious Diseases, 23
  • [2] Diagnostic Accuracy of Xpert MTB/RIF in Sputum Smear-Negative Pulmonary Tuberculosis
    Rasheed, Waqas
    Rao, Nisar Ahmed
    Adel, Hatem
    Baig, Mirza Saifullah
    Adil, Syed Omair
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (08)
  • [3] Xpert Mtb/rif In Diagnosis Of Smear-Negative Pulmonary Tuberculosis
    Kawkitinarong, K.
    Avihingsanon, A.
    Ubolyam, S.
    Ruxrungtham, K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [4] Evaluation of Xpert MTB/RIF Ultra performance for pulmonary tuberculosis diagnosis on smear-negative respiratory samples in a French centre
    Hodille, Elisabeth
    Maisson, Audey
    Charlet, Laurine
    Bauduin, Clyde
    Genestet, Charlotte
    Fredenucci, Isabelle
    Rasigade, Jean-Philippe
    Lina, Gerard
    Dumitrescu, Oana
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2019, 38 (03) : 601 - 605
  • [5] Evaluation of Xpert MTB/RIF Ultra performance for pulmonary tuberculosis diagnosis on smear-negative respiratory samples in a French centre
    Elisabeth Hodille
    Audey Maisson
    Laurine Charlet
    Clyde Bauduin
    Charlotte Genestet
    Isabelle Fredenucci
    Jean-Philippe Rasigade
    Gérard Lina
    Oana Dumitrescu
    European Journal of Clinical Microbiology & Infectious Diseases, 2019, 38 : 601 - 605
  • [6] Diagnostic performance of Xpert MTB/RIF ultra in detecting Mycobacterium tuberculosis and Rifampicin Resistance in AFB Smear-negative Pulmonary and Extrapulmonary Tuberculosis samples in Malaysia
    Noor, Azura Mohd
    Ghazali, Sumarni Mohd
    Abu Bakar, Zamzurina
    Ruzan, Izayu Nurfarha
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2024, 109 (02)
  • [7] Diagnosis of smear-negative tuberculosis is greatly improved by Xpert MTB/RIF
    Lombardi, Giulia
    Di Gregori, Valentina
    Girometti, Nicolo
    Tadolini, Marina
    Bisognin, Francesco
    Dal Monte, Paola
    PLOS ONE, 2017, 12 (04):
  • [8] Evaluation of the Xpert MTB/RIF assay for the diagnosis of smear-negative pulmonary and extrapulmonary tuberculosis in Madagascar
    Rakotoarivelo, R.
    Ambrosioni, J.
    Rasolofo, V.
    Raberahona, M.
    Rakotosamimanana, N.
    Andrianasolo, R.
    Ramanampamonjy, R.
    Tiaray, M.
    Razafimahefa, J.
    Rakotoson, J.
    Randria, M.
    Bonnet, F.
    Calmy, A.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2018, 69 : 20 - 25
  • [9] Usefulness of Xpert MTB/RIF Ultra to Rapidly Diagnose Sputum Smear-Negative Pulmonary Tuberculosis Using Bronchial Washing Fluid
    Chien, Jung-Yien
    Lin, Ching-Kai
    Yu, Chong-Jen
    Hsueh, Po-Ren
    FRONTIERS IN MICROBIOLOGY, 2020, 11
  • [10] Combined tests with Xpert MTB/RIF assay with bronchoalveolar lavage fluid increasing the diagnostic performance of smear-negative pulmonary tuberculosis in Eastern China
    Liu, Qiao
    Ji, Ye
    Martinez, Leonardo
    Lu, Wei
    Shi, Xudong
    Wang, Jianming
    Zeng, Yi
    EPIDEMIOLOGY AND INFECTION, 2020, 149 : e5