Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study

被引:0
|
作者
Htay, Phyo Ei Ei [1 ]
Leesungbok, Richard [2 ,5 ]
Lee, Suk Won [2 ]
Jee, Yu-Jin [3 ]
Kang, Kyung Lhi [4 ]
Hong, Sung Ok [3 ]
机构
[1] Kyung Hee Univ, Coll Dent, Dept Prosthodont, Seoul, South Korea
[2] Kyung Hee Univ, Kyung Hee Univ Dent Hosp Gangdong, Dept Biomat & Prosthodont, Coll Dent, 892 Dongnam Ro, Seoul 05278, South Korea
[3] Kyung Hee Univ, Kyung Hee Univ Dent Hosp Gangdong, Coll Dent, Dept Oral & Maxillofacial Surg, Seoul, South Korea
[4] Kyung Hee Univ, Kyung Hee Univ Dent Hosp Gangdong, Coll Dent, Dept Periodont, Seoul, South Korea
[5] Kyung Hee Univ Coll Dent, Kyung Hee Univ Hosp Gangdong, Dept Pediat Dent, 892 Dongnam ro, Seoul 05278, South Korea
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2023年 / 15卷 / 05期
关键词
Dental implant; Accuracy; CAD-CAM; Surgical guide; Computer-assisted implant surgery; PLACEMENT; ACCURACY; EXPERIENCE; AESTHETICS; TEMPLATES; DENTISTRY;
D O I
10.4047/jap.2023.15.5.259
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This study evaluated the reliability of the chair-side CAD-CAM surgical guide (CSG) in the anterior maxilla by comparing its accuracy with the laboratory 3D-printed surgical guide (3DSG) and manual surgical guide (MSG) concerning different levels of dentists' surgical experience. MATERIALS AND METHODS. Ten surgical guides of each type (MSG, 3DSG, and CSG) were fabricated on a control study model with missing right and left central incisors. Sixty implants were placed in 30 study models by two dentists (one inexperienced and one experienced) using three different types of surgical guides. Horizontal deviations at shoulder and at apex, vertical, and angular deviations were measured after superimposing the planned and placed implant positions in the software. Kruskal-Wallis and Mann-Whitney U tests were used to compare the accuracy of three types of surgical guides in each dentist group and the accuracy of each surgical guide between two dentists (alpha = .05). RESULTS. There were no significant differences in any deviations between CSG and 3DSG, apart from angular deviation, for both dentists' groups. Moreover, both CSG and 3DSG showed no significant differences in accuracy between the two dentists (P > .05). In contrast, MSG demonstrated significant differences from CSG and 3DSG and a significant difference in accuracy between the two dentists (P < .05). CONCLUSION. CSG provides superior accuracy to MSG in implant placement in the maxillary anterior region and is comparable to 3DSG at different levels of surgical experience, while offering the benefits of shorter manufacturing time and reduced patient visits. [J Adv Prosthodont 2023;15:259-70]
引用
收藏
页码:259 / 270
页数:12
相关论文
共 50 条
  • [1] Fabricating a chairside CAD-CAM radiographic and surgical guide for dental implants: A dental technique
    DuVall, Nicholas B.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (01): : 34 - 40
  • [2] Comparative Study of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments
    Tartea, Daniel Adrian
    Ionescu, Mihaela
    Manolea, Horia Octavian
    Mercut, Veronica
    Obadan, Eugenia
    Amarascu, Marina Olimpia
    Marasescu, Petre Costin
    Daguci, Luminita
    Popescu, Sanda Mihaela
    [J]. JOURNAL OF CLINICAL MEDICINE, 2023, 12 (06)
  • [3] Accuracy of Implant Placement Using a CAD/CAM Surgical Guide: An In Vitro Study
    Nokar, Saeid
    Moslehifard, Elnaz
    Bahman, Tootiaii
    Bayanzadeh, Masoud
    Nasirpouri, Farzad
    Nokar, Arash
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (03) : 520 - 526
  • [4] Impact of simulated toothbrushing on surface properties of chairside CAD-CAM materials: An in vitro study
    de Andrade, Guilherme Schmitt
    Augusto, Marina Gullo
    Simoes, Beatriz Venturoso
    Pagani, Clovis
    Anzaloni Saavedra, Guilherme de Siqueira Ferreira
    Bresciani, Eduardo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 469.e1 - 469.e6
  • [5] Reliability of a CAD/CAM Surgical Guide for Implant Placement: An In Vitro Comparison of Surgeons' Experience Levels and Implant Sites
    Park, Su-Jung
    Leesungbok, Richard
    Cui, Taixing
    Lee, Suk Won
    Ahn, Su-Jin
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2017, 30 (04) : 367 - 369
  • [6] CAD-CAM cobalt-chromium surgical template for static computer-aided implant surgery: A dental technique
    Lin, Wei-Shao
    Yang, Chao-Chieh
    Polido, Waldemar D.
    Morton, Dean
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 42 - 44
  • [7] Traditional versus conservative endodontic access impact on fracture resistance of chairside CAD-CAM lithium disilicate anterior crowns: An in vitro study
    Jurado, Carlos A.
    Amarillas-Gastelum, Clarisa
    Honorio Tonin, Bruna Santos
    Nielson, Gentry
    Afrashtehfar, Kelvin, I
    Fischer, Nicholas G.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (08): : 728 - 734
  • [8] Friction and wear behavior of chairside CAD-CAM materials against different types of antagonists: An in vitro study
    Zaim, Beyza
    Kalay, Tugba Serin
    Purcek, Gencaga
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 803 - 813
  • [9] Fatigue fracture resistance of titanium and chairside CAD-CAM zirconia implant abutments supporting zirconia crowns: An in vitro comparative and finite element analysis study
    Giner, Sergio
    Bartolome, Jose F.
    Gomez-Cogolludo, Pablo
    Castellote, Carlos
    Pradies, Guillermo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 503.e1 - 503.e9
  • [10] Adhesive residue on the CAD-CAM surgical guide sleeve: A technical report
    Roe, Phillip
    Rungcharassaeng, Kitichai
    Kan, Joseph Y.
    Putra, Armand
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (05): : 746 - 748