Early Hemodynamic Outcomes in Self-Expandable Valves: Comparison of ACURATE Neo Versus ACURATE Neo2

被引:3
|
作者
Miyashita, Hirokazu [1 ,2 ]
Moriyama, Noriaki [2 ]
Laine, Mika [1 ,3 ,4 ]
机构
[1] Helsinki Univ Cent Hosp, Heart & Lung Ctr, Helsinki, Finland
[2] Shonan Kamakura Gen Hosp, Dept Cardiol, Kamakura, Japan
[3] Univ Helsinki, Heart & Lung Ctr, Haartmaninkatu 4, Helsinki 00290, Finland
[4] Helsinki Univ Cent Hosp, Haartmaninkatu 4, Helsinki 00290, Finland
关键词
Aortic stenosis; Paravalvular leakage; Transcatheter aortic valve replacement; AORTIC-VALVE; ROOT;
D O I
10.1016/j.carrev.2022.08.029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Comparisons of hemodynamic results between ACURATE Neo and ACURATE Neo 2, which have up-dated outer sealing skirts, are limited. This retrospective study aimed to demonstrate the differences in hemody-namic outcomes between the two transcatheter heart valves (THVs).Methods: We included 449 patients who underwent transfemoral transcatheter aortic valve replacement (TAVR) with either ACURATE Neo2 (n = 100) or ACURATE Neo (n = 348) between January 2016 and November 2021. The primary endpoint was the incidence of moderate or severe paravalvular leakage (PVL). The mean aortic pres-sure gradient (APG), peak aortic velocity (AV), and early clinical outcomes were assessed as secondary outcomes.Results: In the propensity-score matching comparison (94 pairs), there were no significant differences in the in-cidence of moderate or severe PVL (4.3 % in Neo2 group vs. 8.5 % in Neo group, p = 0.233), and peak AV and mean APG were significantly higher in Neo2 group (Peak AV: 2.1 +/- 0.4 vs. 1.9 +/- 0.5 m/s, p = 0.003; mean APG: 10.6 +/- 4.8 vs. 9.0 +/- 6.1 mmHg, p = 0.045). In the multivariate logistic regression analysis, the THV type (ACURATE Neo2) was not an independent predictor of moderate or severe PVL.Conclusion: The incidence of moderate or severe PVL did not significantly differ between TAVR with ACURATE Neo2 and ACURATE Neo; however, it was numerically lower in ACURATE Neo2. In contrast, the Neo2 group had a higher residual mean APG and peak AV. A larger study with long-term follow-up is warranted to assess the clinical relevance of these findings.(c) 2022 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:62 / 69
页数:8
相关论文
共 50 条
  • [21] Commissural Alignment With ACURATE neo2 Valve in an Unselected Population
    Meduri, Christopher U.
    Ruck, Andreas
    Linder, Rickard
    Verouhis, Dinos
    Settergren, Magnus
    Sorajja, Amalin
    Daher, Daniel
    Saleh, Nawzad
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (06) : 670 - 677
  • [22] Multicenter comparison of transcatheter aortic valve implantation with the self-expanding ACURATE neo2 versus Evolut PRO transcatheter heart valves
    Tobias Rheude
    Costanza Pellegrini
    Martin Landt
    Sabine Bleiziffer
    Alexander Wolf
    Matthias Renker
    Jonas Neuser
    Oliver Dörr
    Abdelhakim Allali
    Tanja K. Rudolph
    Jan Martin Wambach
    Julian D. Widder
    Parminder Singh
    Dominik Berliner
    Hector A. Alvarez-Covarrubias
    Gert Richardt
    Erion Xhepa
    Won-Keun Kim
    Michael Joner
    Clinical Research in Cardiology, 2024, 113 : 38 - 47
  • [23] ACURATE neo2: jack of all trades or master of none?
    Sinning, Jan-Malte
    EUROINTERVENTION, 2023, 19 (01) : 18 - 19
  • [24] Technical Considerations for Transcatheter Aortic Valve Replacement With ACURATE neo2
    Wong, Ivan
    Bieliauskas, Gintautas
    De Backer, Ole
    Sondergaard, Lars
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (02) : 224 - 226
  • [25] Transcatheter Aortic Valve Replacement With Self-Expanding ACURATE neo2 Postprocedural Hemodynamic and Short-Term Clinical Outcomes
    Buono, Andrea
    Gorla, Riccardo
    Ielasi, Alfonso
    Costa, Giuliano
    Cozzi, Ottavia
    Ancona, Marco
    Soriano, Francesco
    De Carlo, Marco
    Ferrara, Erica
    Giannini, Francesco
    Massussi, Mauro
    Fovino, Luca Nai
    Pero, Gaetano
    Bettari, Luca
    Acerbi, Elena
    Messina, Antonio
    Sgroi, Carmelo
    Pellicano, Mariano
    Sun, Jinwei
    Gallo, Francesco
    Franchina, Antonio Gabriele
    Bruno, Francesco
    Nerla, Roberto
    Saccocci, Matteo
    Villa, Emmanuel
    D'Ascenzo, Fabrizio
    Conrotto, Federico
    Cuccia, Claudio
    Tarantini, Giuseppe
    Fiorina, Claudia
    Castriota, Fausto
    Poli, Arnaldo
    Petronio, Anna Sonia
    Oreglia, Jacopo
    Montorfano, Matteo
    Regazzoli, Damiano
    Reimers, Bernhard
    Tamburino, Corrado
    Tespili, Maurizio
    Bedogni, Francesco
    Barbanti, Marco
    Maffeo, Diego
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (11) : 1101 - 1110
  • [26] Comparison of transcatheter aortic valve replacement with the ACURATE neo2 versus Evolut PRO/PRO plus devices
    Baggio, Sara
    Pagnesi, Matteo
    Kim, Won-Keun
    Scotti, Andrea
    Barbanti, Marco
    Costa, Giuliano
    Adamo, Marianna
    Kornowski, Ran
    Vaknin-Assa, Hana
    Estevez-Loureiro, Rodrigo
    Cedeno, Robert Alarcon
    De Marco, Federico
    Casenghi, Matteo
    Toggweiler, Stefan
    Veulemans, Verena
    Mylotte, Darren
    Lunardi, Mattia
    Regazzoli, Damiano
    Reimers, Bernhard
    Sondergaard, Lars
    Vanhaverbeke, Maarten
    Nuyens, Philippe
    Maffeo, Diego
    Buono, Andrea
    Saccocci, Matteo
    Giannini, Francesco
    Di Ienno, Luca
    Ferlini, Marco
    Lanzillo, Giuseppe
    Ielasi, Alfonso
    Schofer, Joachim
    Brinkmann, Christina
    Heyden, Jan Van Der
    Buysschaert, Ian
    Eitan, Amnon
    Wolf, Alexander
    Adamaszek, Martin Marian
    Colombo, Antonio
    Latib, Azeem
    Mangieri, Antonio
    EUROINTERVENTION, 2023, 18 (12) : 977 - +
  • [27] Haemodynamic performance and clinical outcomes of transcatheter aortic valve replacement with the self- expanding ACURATE neo2
    Scotti, Andrea
    Pagnesi, Matteo
    Kim, Won-Keun
    Schafer, Ulrich
    Barbanti, Marco
    Costa, Giuliano
    Baggio, Sara
    Casenghi, Matteo
    De Marco, Federico
    Vanhaverbeke, Maarten
    Sondergaard, Lars
    Wolf, Alexander
    Schofer, Joachim
    Ancona, Marco Bruno
    Montorfano, Matteo
    Kornowski, Ran
    Assa, Hana Vaknin
    Toggweiler, Stefan
    Ielasi, Alfonso
    Hildick-Smith, David
    Windecker, Stephan
    Schmidt, Albrecht
    Buono, Andrea
    Maffeo, Diego
    Siqueira, Dimytri
    Giannini, Francesco
    Adamo, Marianna
    Massussi, Mauro
    Wood, David A.
    Sinning, Jan-Malte
    Van der Heyden, Jan
    Van Ginkel, Dirk-Jan
    Van Mieghem, Nicholas
    Veulemans, Verena
    Mylotte, Darren
    Tzalamouras, Vasileios
    Taramasso, Maurizio
    Estevez-Loureiro, Rodrigo
    Colombo, Antonio
    Mangieri, Antonio
    Latib, Azeem
    EUROINTERVENTION, 2022, 18 (10) : 804 - +
  • [28] TAVI WITH SAPIEN 3 ULTRA AND ACURATE NEO2: OUTCOMES FROM A HIGH VOLUME CENTER
    Motta, Silvia Crescenzia
    Costa, Giuliano
    Strazzieri, Orazio
    Di Pietro, Elena
    Frittitta, Valentina
    Barbanti, Marco
    Tamburino, Corrado
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2022, 24
  • [29] First implantation of the Acurate neo2 prosthesis in a patient with aortic stenosis in Poland
    Olasinska-Wisniewska, Anna
    Misterski, Marcin
    Araszkiewicz, Aleksander
    Stefaniak, Sebastian
    Komosa, Anna
    Jemielity, Marek
    Lesiak, Maciej
    Grygier, Marek
    KARDIOLOGIA POLSKA, 2021, 79 (02) : 207 - 208
  • [30] Coronary access techniques following ACURATE neo2 implantation in surgical bioprosthesis
    Khokhar, Arif A.
    Ponticelli, Francesco
    Zlahoda-Huzior, Adriana
    Zakrzewski, Pawel
    Mikhail, Ghada
    Dudek, Dariusz
    Giannini, Francesco
    EUROINTERVENTION, 2022, 18 (10) : 820 - +