Comparative assessment of night ventilation performance in a nearly zero-energy office building during heat waves in Brussels

被引:7
|
作者
Amaripadath, Deepak [1 ]
Paolini, Riccardo [2 ]
Sailor, David J. [3 ]
Attia, Shady [1 ]
机构
[1] Univ Liege, Fac Appl Sci, Dept UEE, Sustainable Bldg Design Lab, B-4000 Liege, Belgium
[2] Univ New South Wales UNSW, Fac Arts Design & Architecture, Sch Built Environm, Sydney, NSW, Australia
[3] Arizona State Univ, Sch Geog Sci & Urban Planning, Tempe, AZ USA
来源
关键词
Natural night ventilation; Mechanical night ventilation; Overheating; Microclimates; Thermal-energy simulations; URBAN HEAT; OVERHEATING RISK; IMPACT; ISLAND; SIMULATION; CLIMATE; DESIGN; OPTIMIZATION; CONSUMPTION; ADAPTATIONS;
D O I
10.1016/j.jobe.2023.107611
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
With increasing urbanization, overheating intensifies, resulting in a greater risk of indoor overheating in commercial buildings, which already have high internal gains. The impact of urban climate on the cooling energy needs of buildings has been extensively researched. However, the building performance during extreme heat events needs further investigation to reduce the energy demand from the grid during critical events and to ensure an acceptable indoor thermal environment. Here, a comparative assessment approach for natural and mechanical night ventilation performance to reduce indoor overheating and energy needs of a nearly zero-energy office building in Brussels, Belgium, was evaluated for the heat wave and non-heat wave periods in urban and rural microclimates, using calibrated thermal-energy simulations. The analysis indicated that active cooling with natural night ventilation was more effective during heat waves than other cooling strategies. In addition, natural night ventilation was also effective in maintaining safer levels of heat index values in the reference office compared to other strategies. Natural night ventilation reduced overheating by 0.39 degrees C in the urban microclimate and 0.50 degrees C in the rural microclimate relative to the Baseline. Considering the cooling energy use, natural night ventilation had no significant impact. In contrast, mechanical night ventilation increased energy use by 0.54 kWh/m2 in urban microclimate and 0.40 kWh/m2 in rural microclimate due to prolonged ventilation fan operation in the reference office building. The presented findings in the paper lead to the formulation of design guidelines, recommendations for future practices and identifying needs for further research.
引用
收藏
页数:18
相关论文
共 37 条
  • [1] Climate change sensitive sizing and design for nearly zero-energy office building systems in Brussels
    Amaripadath, D.
    Rahif, R.
    Zuo, W.
    Velickovic, M.
    Voglaire, C.
    Attia, S.
    [J]. ENERGY AND BUILDINGS, 2023, 286
  • [2] Geothermal heat pump plant performance in a nearly zero-energy building
    Fadejev, Jevgeni
    Simson, Raimo
    Kurnitski, Jarek
    Kesti, Jyrki
    Mononen, Tarmo
    Lautso, Petteri
    [J]. Sustainable Built Environment Tallinn and Helsinki Conference SBE16 Build Green and Renovate Deep, 2016, 96 : 489 - 502
  • [3] Thermal resilience in a renovated nearly zero-energy dwelling during intense heat waves
    Amaripadath, Deepak
    Joshi, Mitali Yeshwant
    Hamdy, Mohamed
    Petersen, Steffen
    Stone Jr, Brian
    Attia, Shady
    [J]. JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2023,
  • [4] Performance dataset on a nearly zero-energy office building in temperate oceanic climate based on field measurements
    Amaripadath, Deepak
    Attia, Shady
    [J]. DATA IN BRIEF, 2023, 48
  • [5] Performance Evaluation of a Nearly Zero-Energy Office Building in Temperate Oceanic Climate Based on Field Measurements
    Amaripadath, Deepak
    Velickovic, Mirjana
    Attia, Shady
    [J]. ENERGIES, 2022, 15 (18)
  • [6] Heat exposure mitigation in renovated nearly zero-energy dwellings during concurrent heat waves and power outages
    Amaripadath, Deepak
    Azar, Elie
    Singh, Manoj Kumar
    Attia, Shady
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 91
  • [7] On the improvement of indoor environmental quality, energy performance and costs for a commercial nearly zero-energy building
    De Luca, Giovanna
    Ballarini, Ilaria
    Paragamyan, Argun
    Pellegrino, Anna
    Corrado, Vincenzo
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2021, 27 (08) : 1056 - 1074
  • [8] Energy and economic performance assessment of efficiency measures in zero-energy office buildings in Greece
    Pallis, Platon
    Braimakis, Konstantinos
    Roumpedakis, Tryfon C.
    Varvagiannis, Efstratios
    Karellas, Sotirios
    Doulos, Lambros
    Katsaros, Miltiadis
    Vourliotis, Panagiotis
    [J]. BUILDING AND ENVIRONMENT, 2021, 206
  • [9] Cooling system energy flexibility of a nearly zero-energy office building using building thermal mass: Potential evaluation and parametric analysis
    Lu, Fei
    Yu, Zhenyu
    Zou, Yu
    Yang, Xudong
    [J]. ENERGY AND BUILDINGS, 2021, 236
  • [10] Assessing Efficiency and Environmental Performance of a Nearly Zero-Energy University Building's Energy System in Norway
    Abrahamsen, Fredrik Ege
    Ruud, Sturla Grina
    Gebremedhin, Alemayehu
    [J]. BUILDINGS, 2023, 13 (01)