Thermodynamic performance evaluation of an innovative steam compressor using zeolite-water adsorption reactor

被引:4
|
作者
Buzzi, Fulvio [1 ]
Di Palo, Michelangelo [2 ]
Gabbrielli, Roberto [1 ]
机构
[1] Univ Pisa, Dipartimento Ingn Civile & Ind, I-56126 Pisa, Italy
[2] Glayx Tech Srl, I-56025 Pontedera, PI, Italy
关键词
Zeolite; Steam compressor; Modelling; Adsorption; Waste Heat Recovery; SORPTION HEAT-STORAGE; GRADE WASTE HEAT; PUMPS;
D O I
10.1016/j.applthermaleng.2022.119954
中图分类号
O414.1 [热力学];
学科分类号
摘要
The industrial sector is a large energy consumer producing huge amounts of low enthalpy waste steam which can be compressed to increase its condensation pressure for its subsequent effective use. In this paper, adsorption technology was used to increase the waste steam enthalpy since this process requires small amounts of electrical energy. An innovative configuration of the adsorption compressors is presented involving direct contact between an adsorbent bed and the waste steam. The direct-contact design avoids the use of a heat exchanger between the steam and the zeolite adsorbent material, thus reducing the geometry complexity and the overall cost. The direct -contact technology is new and generally studied for heat pump purposes. This paper numerically investigates the physical feasibility of the process highlighting its main advantages and limitations. The results show a promising thermodynamic behaviour suggesting the possibility of using this adsorption compressor for several industrial processes involving higher than 7 bar steam pressure and pressure ratios up to 1.26. The steam consumption was lower than one order of magnitude of the usable compressed steam.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Adsorption cold storage system with zeolite-water working pair used for locomotive air-conditioning
    Lu, YZ
    Wang, RZ
    Jiangzhou, S
    Xu, YX
    Wu, JY
    PROCEEDINGS OF THE INTERNATIONAL SORPTION HEAT PUMP CONFERENCE, 2002, : 484 - 489
  • [32] THERMODYNAMIC CHARACTERISTICS OF WATER ADSORPTION IN AgZSM-5 ZEOLITE
    Kuldasheva, Shakhnoza A.
    Abdulkhaev, Tolibjon D.
    Bakhronov, Khayot N.
    Rakhmatkarieva, Feruza G.
    Nortojiyeva, Gulbahor R.
    PROCESSES OF PETROCHEMISTRY AND OIL REFINING, 2023, 24 (03): : 454 - 462
  • [33] Evaluation of the effects of water injection on compressor performance
    White, AJ
    Meacock, AJ
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2004, 126 (04): : 748 - 754
  • [34] Performance of zeolite - Water modular adsorption air conditioner
    Maiya, MP
    Arasappan, K
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 428 - 431
  • [35] Comparative thermodynamic analysis of adsorption, membrane and adsorption-membrane hybrid reactor systems for methanol steam reforming
    Katiyar, Nisha
    Kumar, Shashi
    Kumar, Surendra
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (03) : 1363 - 1375
  • [36] THE STEAM TURBINE RETROFITTING OF SIX BOILING WATER REACTOR UNITS USING INNOVATIVE ENGINEERING AND LASER SCANNING TECHNIQUES
    Jones, Mike
    Nelmes, David. J.
    ASME POWER CONFERENCE 2009, 2009, : 255 - 263
  • [38] Sludge collector performance in steam generators of pressurized water reactor
    Takamatsu, H
    Matsunaga, T
    Wilson, RM
    Kusakabe, T
    NUCLEAR ENGINEERING AND DESIGN, 2000, 200 (1-2) : 295 - 302
  • [39] PERFORMANCE OF INTERNAL STEAM SEPARATION SYSTEM IN BOILING WATER REACTOR
    BURLEY, EL
    COMBUSTION, 1971, 43 (01): : 21 - &
  • [40] Energy performance assessment of a novel zeolite-water direct contact adsorptive heat pump for waste heat recovery
    Buzzi, Fulvio
    Di Palo, Michelangelo
    Gabbrielli, Roberto
    ENERGY CONVERSION AND MANAGEMENT-X, 2022, 13