Thermal performance of two evacuated tube solar collectors with flat heat pipes

被引:6
|
作者
Zhang, Dengke [1 ]
Diao, Yanhua [1 ]
Wang, Zeyu [2 ]
Pan, Yawen [1 ]
Sun, Mengda [1 ]
Wang, Xinran [1 ]
Du, Peiyuan [1 ]
Zhao, Yaohua [1 ,3 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Green Built Environm & Efficient T, Beijing 100124, Peoples R China
[2] China Nucl Power Engn Co Ltd, Beijing 100089, Peoples R China
[3] Zibo Boienergy Sci & Technol Co Ltd, Shandong 255000, Peoples R China
关键词
Flat micro-heat pipe array; Multi-channel flat tube; Louver fin; Solar water collector; Evacuated tube collector; AIR HEATER; PLATE; SYSTEMS; DESIGN;
D O I
10.1016/j.applthermaleng.2024.122366
中图分类号
O414.1 [热力学];
学科分类号
摘要
To promote the transition to clean heating methods in rural areas and improve solar energy utilization efficiency, two new types of solar water collectors with evacuated tubes, namely finned and finless collectors, are constructed with multi-channel flat tubes and flat micro-heat pipe arrays, and comparison experiments are conducted. By integrating with multi-channel flat tubes, the micro-heat pipe arrays, which function as the central heat transfer component, are capable of attaining effective thermal transmission. The multi-channel flat tubes have a substantial surface area available for heat transfer with the thermal fluid, while the evacuated tubes exhibit superior thermal insulation performance. The structural discrepancy between the two collectors lies in the presence or absence of louvered fins attached to the flat heat pipes inside the evacuated tubes. The comparative analysis of the two collectors includes time constant, thermal resistance analysis, distribution of temperature, normalized temperature difference, pressure drop, and actual operation effect under different conditions. The average thermal efficiency of the finless collector (59.4 %) is lower than that of the finned collector (78.2 %) on a typical experimental day. Then, further investigations are conducted to explore the effects of heat transfer fluid volume flow rate and inlet temperature on the thermal performance of finned solar water collector. With the heat transfer fluid volume flow rate of 120 L/h and the inlet temperature at 15 C, the finned collector can achieve its maximum thermal efficiency of 86.4 %.
引用
收藏
页数:25
相关论文
共 50 条
  • [21] Thermal performance enhancement of micro-grooved aluminum flat plate heat pipes applied in solar collectors
    Chen, Gong
    Tang, Yong
    Duan, Longhua
    Tang, Heng
    Zhong, Guisheng
    Wan, Zhenping
    Zhang, Shiwei
    Fu, Ting
    RENEWABLE ENERGY, 2020, 146 : 2234 - 2242
  • [22] The sizes of Flat Plate and Evacuated Tube Collectors with Heat Pipe area as a function of the share of solar system in the heat demand
    Olek, Malgorzata
    Olczak, Piotr
    Kryzia, Dominik
    1ST INTERNATIONAL CONFERENCE ON THE SUSTAINABLE ENERGY AND ENVIRONMENT DEVELOPMENT (SEED 2016), 2016, 10
  • [23] Economic feasibility of flat plate vs evacuated tube solar collectors in a combisystem
    Najera-Trejo, Mario
    Martin-Domiguez, Ignacio R.
    Escobedo-Bretado, Jorge A.
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2015), 2016, 91 : 477 - 485
  • [24] ENERGY AND EXERGY EFFICIENCY OF HEAT PIPE EVACUATED TUBE SOLAR COLLECTORS
    Jafarkazemi, Farzad
    Ahmadifard, Emad
    Abdi, Hossein
    THERMAL SCIENCE, 2016, 20 (01): : 327 - 335
  • [25] Utilizing Gene-Expression Programming in Modelling the Thermal Performance of Evacuated Tube Solar Collectors
    Sadeghi, Gholamabbas
    Najafzadeh, Mohammad
    Safarzadeh, Habibollah
    JOURNAL OF ENERGY STORAGE, 2020, 30
  • [26] On the integration of phase change materials with evacuated tube solar thermal collectors
    Aramesh, M.
    Shabani, B.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2020, 132
  • [27] Thermal and economic analyses of solar desalination system with evacuated tube collectors
    Liu, Xiaohua
    Chen, Wenbo
    Gu, Ming
    Shen, Shengqiang
    Cao, Guojian
    SOLAR ENERGY, 2013, 93 : 144 - 150
  • [28] Design of a solar-driven cogeneration system using flat plate collectors and evacuated tube collectors
    Bellos, Evangelos
    Tzivanidis, Christos
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (11) : 5841 - 5851
  • [29] Examination of a solar desalination system equipped with an air bubble column humidifier, evacuated tube collectors and thermosyphon heat pipes
    Behnam, Pooria
    Shafii, Mohammad Behshad
    DESALINATION, 2016, 397 : 30 - 37
  • [30] ALL-DAY PERFORMANCE OF EVACUATED TUBE COLLECTORS AND EVACUATED TUBE COLLECTORS IN SERIES.
    Cu, Yi-feng
    Han, Lai-sheng
    Wang, Xing-an
    1600, (07):