Diagnostic value of multi-slice spiral computed tomography angiography for intracranial aneurysm

被引:0
|
作者
Yan, Jilai [1 ]
机构
[1] Nanjing Med Univ, Dept Radiol, Affiliated Hosp 1, 300 Guangzhou Rd, Nanjing 210029, Jiangsu, Peoples R China
关键词
Accuracy; Angiography; Intracranial aneurysm; Multi-slice spiral CT; CT ANGIOGRAPHY;
D O I
10.1007/s10072-024-07418-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective To investigate the clinical value of multi-slice spiral computed tomography angiography (MSCTA) in the diagnosis of intracranial aneurysms (ICA). Methods The imaging data of 68 patients suspected of having ICA who were examined in the Department of Radiology of the First Affiliated Hospital of Nanjing Medical University from March 2018 to March 2021 were retrospectively analyzed. MSCTA and digital subtraction angiography (DSA) were performed on each patient, and the MSCTA imaging analysis was compared with DSA. Results The accuracy of DSA in the diagnosis of ICA was 98.53% (67/68), while the accuracy of MSCTA in the diagnosis of ICA was 97.06% (66/68), with no significant difference in diagnostic accuracy (P > 0.05). There were no significant differences in the diameter of the aneurysm, the width of the aneurysm neck, or the location of the aneurysm in the comparison of the ICA image between DSA and MSCTA (P > 0.05). Conclusion MSCTA offers high accuracy and has favorable clinical value in the diagnosis of ICA. It is worth popularizing as the recommended examination method in clinical practice
引用
收藏
页码:3901 / 3905
页数:5
相关论文
共 50 条
  • [21] Multi-Slice Computed Tomography Coronary Angiography for Detection of Coronary Anomalies
    Qin, Xuguang
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (17) : S80 - S81
  • [22] Multi-Slice Computed Tomography Coronary Angiography for Detection of Coronary Anomalies
    Qin, Xuguang
    Xiong, Weiguo
    Lu, Chunpeng
    Gong, Chengjie
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (07): : 126S - 127S
  • [23] Multi-slice technology in computed tomography
    Dawson, P
    Lees, WR
    [J]. CLINICAL RADIOLOGY, 2001, 56 (04) : 302 - 309
  • [24] Multi-slice computed tomography in dilated cardiomyopathy: comparison with myocardial biopsy, diagnostic and prognostic value
    Blagova, O. V.
    Blagova, O. V.
    Gagarina, N. V.
    Nedostup, A. V.
    Sulimov, V. A.
    Kogan, E. A.
    Kupryanova, A. G.
    Zaidenov, V. A.
    Donnikov, A. E.
    [J]. EUROPEAN HEART JOURNAL, 2013, 34 : 774 - 774
  • [25] Combined cardiac congenital anomalies assessed by multi-slice spiral computed tomography
    Rius, T
    Goyenechea, M
    Poon, M
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 (06) : 637 - 637
  • [26] Noninvasive angiographic evaluation of coronary stents with multi-slice spiral computed tomography
    Nieman, K
    Cademartiri, F
    Raaijmakers, R
    Pattynama, P
    de Feyter, P
    [J]. HERZ, 2003, 28 (02) : 136 - 142
  • [27] Diagnostic accuracy of multi-slice computed tomography in children with Abernethy malformation
    Chen Guo
    Yu-Min Zhong
    Qian Wang
    Li-Wei Hu
    Xiao-Hong Gu
    Hong Shao
    Wei Wu
    Jian-Feng Cao
    Hai-Sheng Qiu
    [J]. BMC Medical Imaging, 19
  • [28] Diagnostic accuracy of multi-slice computed tomography in children with Abernethy malformation
    Guo, Chen
    Zhong, Yu-Min
    Wang, Qian
    Hu, Li-Wei
    Gu, Xiao-Hong
    Shao, Hong
    Wu, Wei
    Cao, Jian-Feng
    Qiu, Hai-Sheng
    [J]. BMC MEDICAL IMAGING, 2019, 19 (01)
  • [29] The diagnosis of coronary plaque stability by multi-slice computed tomography coronary angiography
    Song, Feng-Xiang
    Zhou, Jun
    Zhou, Jian-Jun
    Shi, Yu-Xin
    Zeng, Meng-Su
    Zhang, Zhi-Yong
    Lv, Peng
    Sheng, Ruo-Fan
    [J]. JOURNAL OF THORACIC DISEASE, 2018, 10 (04) : 2365 - +
  • [30] Interruption of aortic arch in a neonate: Diagnosis by multi-slice spiral computed tomographic angiography
    Hou, Z. B.
    Li, X.
    Wang, C. X.