Flexible Capillary Microfluidic Devices Based on Surface-Energy Modified Polydimethylsiloxane and Polymethylmethacrylate with Room-Temperature Chemical Bonding

被引:11
|
作者
Huyen, Lai Thi Ngoc [1 ]
Hong, Seok Ju [1 ]
Trung, Tran Quang [1 ]
Meeseepong, Montri [2 ]
Kim, A. Ri [2 ]
Lee, Nae-Eung [1 ,2 ,3 ]
机构
[1] Sungkyunkwan Univ, Sch Adv Mat Sci & Engn, Suwon 16419, Gyeonggi Do, South Korea
[2] Sungkyunkwan Univ, SKKU Adv Inst Nanotechnol SAINT, Suwon 16419, Gyeonggi Do, South Korea
[3] Sungkyunkwan Univ, Samsung Adv Inst Hlth Sci & Technol SAIHST, Suwon 16419, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
Flexible capillary microfluidic; PMMA; Modified-PDMS; Room-temperature bonding; Hydrophilicity; OXYGEN-PLASMA; PDMS; POLY(DIMETHYLSILOXANE); PEO;
D O I
10.1007/s13206-023-00096-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Polydimethylsiloxane (PDMS) has been widely used for the rapid prototyping of microfluidic devices for biosensor cartridges. However, using PDMS to prototype capillary-driven microfluidic devices is often limited by the difficulty of maintaining the surface energy of surface-treated PDMS for an extended period in addition to the degradation of the biosensing elements during the bonding process at elevated temperature. Herein, prototyping of a flexible capillary microfluidic channel (FCMC) device based on the room-temperature bonding of the surface energy-modified PDMS (m-PDMS) microfluidic channel and a thermoplastic lid, polymethylmethacrylate (PMMA), is introduced for prolonged control of passive liquid flow characteristics. The m-PDMS was fabricated by blending polydimethylsiloxane-ethylene oxide (60-70%) block copolymer (PDMS-b-PEO) additive with pre-PDMS, of which the water contact angles could be controlled between 38.5 degrees and 78.5 degrees by adjusting the ratio of the two components. Room-temperature bonding of the m-PDMS and PMMA sheets functionalized by 3-glycidoxypropyltrimethoxysilane and aminopropyltriethoxysilane, respectively, was introduced to fabricate the FCMC devices via the formation of a stable linker epoxy-amine without the requirement of elevated temperatures. The FCMC device possessed longevity to passively drive liquid in the channel for 2 months under ambient conditions due to the prolonged stable hydrophilicity of m-PDMS. The proposed approaches provide great potential for prototyping passive microfluidic devices for biosensor cartridge applications.
引用
收藏
页码:120 / 132
页数:13
相关论文
共 23 条
  • [1] Flexible Capillary Microfluidic Devices Based on Surface-Energy Modified Polydimethylsiloxane and Polymethylmethacrylate with Room-Temperature Chemical Bonding
    Lai Thi Ngoc Huyen
    Seok Ju Hong
    Tran Quang Trung
    Montri Meeseepong
    A Ri Kim
    Nae-Eung Lee
    BioChip Journal, 2023, 17 : 120 - 132
  • [2] Room-temperature intermediate layer bonding for microfluidic devices
    Bart, Jacob
    Tiggelaar, Roald
    Yang, Menglong
    Schlautmann, Stefan
    Zuilhof, Han
    Gardeniers, Han
    LAB ON A CHIP, 2009, 9 (24) : 3481 - 3488
  • [3] A room-temperature bonding technique for the packaging of hydrogel-based hybrid microfluidic devices
    Tommaso Santaniello
    Yunsong Yan
    Alessandro Tocchio
    Federico Martello
    Paolo Milani
    Cristina Lenardi
    Microfluidics and Nanofluidics, 2015, 19 : 31 - 41
  • [4] A room-temperature bonding technique for the packaging of hydrogel-based hybrid microfluidic devices
    Santaniello, Tommaso
    Yan, Yunsong
    Tocchio, Alessandro
    Martello, Federico
    Milani, Paolo
    Lenardi, Cristina
    MICROFLUIDICS AND NANOFLUIDICS, 2015, 19 (01) : 31 - 41
  • [5] Click-and-Bond: Room-Temperature and Solvent-Free Bonding of Polymer-Based Microfluidic Devices
    Di Iorio, Daniele
    Rameshbabu, Sharath
    Bruijns, Brigitte
    Movilli, Jacopo
    Skolimowski, Maciej
    Huskens, Jurriaan
    ADVANCED MATERIALS INTERFACES, 2022, 9 (23):
  • [6] Characterization of Hysteresis of Surface Energy in Room-Temperature Direct Bonding Processes
    Grierson, David S.
    Turner, Kevin T.
    SEMICONDUCTOR WAFER BONDING 11: SCIENCE, TECHNOLOGY, AND APPLICATIONS - IN HONOR OF ULRICH GOSELE, 2010, 33 (04): : 573 - 580
  • [7] Room-Temperature Bonding Technique Based on Copper Nanowire Surface Fastener
    Wang, Peng
    Ju, Yang
    Chen, Mingji
    Hosoi, Atsushi
    Song, Yuanhui
    Iwasaki, Yuka
    APPLIED PHYSICS EXPRESS, 2013, 6 (03)
  • [8] Bonding of glass-based microfluidic chips at low- or room-temperature in routine laboratory
    Chen, Lingxin
    Luo, Guoan
    Liu, Kehui
    Ma, Jiping
    Yao, Bo
    Yan, Yongchen
    Wang, Yiming
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 119 (01) : 335 - 344
  • [9] Room-temperature wafer bonding of SiC-Si by modified surface activated bonding with sputtered Si nanolayer
    Mu, Fengwen
    Iguchi, Kenichi
    Nakazawa, Haruo
    Takahashi, Yoshikazu
    Fujino, Masahisa
    Suga, Tadatomo
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2016, 55 (04)
  • [10] A universal approach for irreversible bonding of rigid substrate-based microfluidic devices at room temperature
    Xiaoyong Ku
    Guisheng Zhuang
    Gang Li
    Microfluidics and Nanofluidics, 2018, 22