An open-source development based on photogrammetry for a real-time IORT treatment planning system

被引:1
|
作者
Lozares-Cordero, Sergio [1 ,8 ]
Bermejo-Barbanoj, Carlos [2 ]
Badias-Herbera, Alberto [3 ]
Ibanez-Carreras, Reyes [4 ]
Ligorred-Padilla, Luis [5 ]
Ponce-Ortega, Jose Miguel
Gonzalez-Perez, Victor [6 ]
Gandia-Martinez, Almudena [1 ]
Font-Gomez, Jose Antonio [1 ]
Blas-Borroy, Olga [7 ]
Gonzalez-Ibanez, David [2 ]
机构
[1] Miguel Servet Univ Hosp, Phys & Radiat Protect Dept, Zaragoza, Spain
[2] Univ Zaragoza, Aragon Inst Engn Res, Zaragoza, Spain
[3] Univ Politecn Madrid, Higher Tech Sch Ind Engn, Madrid, Spain
[4] Miguel Servet Univ Hosp, Radiat Oncol Dept, Zaragoza, Spain
[5] Miguel Servet Univ Hosp, Dept Gen & Gastrointestinal Surg, Esophagogastr Surg & Sarcoma Unit, Zaragoza, Spain
[6] IVO Fdn, Med Physicist Dept, Valencia, Spain
[7] Miguel Servet Univ Hosp, Engn & Maintenance Serv, Zaragoza, Spain
[8] Miguel Servet Univ Hosp, Paseo Isabel Catol 1-3, Zaragoza 50009, Spain
关键词
IORT; TPS; Photogrammetry; Radiochromic films; Electronic brachytherapy; IN-VIVO DOSIMETRY; RADIOCHROMIC FILM DOSIMETRY; SOFT-TISSUE SARCOMA; RADIATION-THERAPY; BRACHYTHERAPY; RECOMMENDATIONS; RADIOTHERAPY; CALIBRATION; MODEL; WATER;
D O I
10.1016/j.ejmp.2023.102622
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study presents a treatment planning system for intraoperative low-energy photon radiotherapy based on photogrammetry from real images of the surgical site taken in the operating room.Material and methods: The study population comprised 15 patients with soft-tissue sarcoma. The system obtains the images of the area to be irradiated with a smartphone or tablet, so that the absorbed doses in the tissue can be calculated from the reconstruction without the need for computed tomography.The system was commissioned using 3D printing of the reconstructions of the tumor beds. The absorbed doses at various points were verified using radiochromic films that were suitably calibrated for the corresponding energy and beam quality.Results: The average reconstruction time of the 3D model from the video sequence in the 15 patients was 229,6 & PLUSMN;7,0 s. The entire procedure, including video capture, reconstruction, planning, and dose calculation was 520,6 & PLUSMN;39,9 s. Absorbed doses were measured on the 3D printed model with radiochromic film, the differences between these measurements and those calculated by the treatment planning system were 1.4% at the applicator surface, 2.6% at 1 cm, 3.9% at 2 cm and 6.2% at 3 cm.Conclusions: The study shows a photogrammetry-based low-energy photon IORT planning system, capable of obtaining real-time images inside the operating room, immediately after removal of the tumor and immediately before irradiation. The system was commissioned with radiochromic films measurements in 3D-printed model.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Real-Time Processing Library for Open-Source Hardware Biomedical Sensors
    Molina-Cantero, Alberto J.
    Castro-Garcia, Juan A.
    Lebrato-Vazquez, Clara
    Gomez-Gonzalez, Isabel M.
    Merino-Monge, Manuel
    SENSORS, 2018, 18 (04)
  • [22] Open-source framework for data storage and visualization of real-time experiments
    Prabakar, Kumaraguru
    Wunder, Nick
    Brunhart-Lupo, Nicholas
    Pailing, Courtney
    Potter, Kristi
    Eash, Matthew
    Munch, Kristin
    2020 IEEE KANSAS POWER AND ENERGY CONFERENCE (KPEC), 2020,
  • [23] Adapting open-source drone autopilots for real-time iceberg observations
    Carlson, Daniel F.
    Rysgaard, Soren
    METHODSX, 2018, 5 : 1059 - 1072
  • [24] An Open-Source and Wearable System for Measuring 3D Human Motion in Real-Time
    Slade, Patrick
    Habib, Ayman
    Hicks, Jennifer L.
    Delp, Scott L.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (02) : 678 - 688
  • [25] An Open-Source Dialog System with Real-Time Engagement Tracking for Job Interview Training Applications
    Yu, Zhou
    Ramanarayanan, Vikram
    Lange, Patrick
    Suendermann-Oeft, David
    ADVANCED SOCIAL INTERACTION WITH AGENTS, 2019, 510 : 199 - 207
  • [26] OPEN-SOURCE REAL-TIME ROBOT OPERATION AND CONTROL SYSTEM FOR HIGHLY DYNAMIC, MODULAR MACHINES
    Peekema, Andrew
    Renjewski, Daniel
    Hurst, Jonathan
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2013, VOL 7A, 2014,
  • [27] Apply open source to real-time application development
    1600, CMP Asia Ltd.- New York Office
  • [28] Real-Time Laser Source Tracking for Pleural PDT Treatment Planning System
    Chang, C.
    Zhu, T. C.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [29] Pandia: Open-source Framework for DRL-based Real-time Video Streaming Control
    Li, Xuebing
    Vikberg, Esa
    Cho, Byungjin
    Xiao, Yu
    PROCEEDINGS OF THE 2024 15TH ACM MULTIMEDIA SYSTEMS CONFERENCE 2024, MMSYS 2024, 2024, : 299 - 305
  • [30] An Open-Source IoT Power Outlet System for Scheduling Appliance Operation Intervals Based on Real-Time Electricity Cost
    Blanco-Novoa, Oscar
    Fernandez-Carames, Tiago M.
    Fraga-Lamas, Paula
    Castedo, Luis
    2017 IEEE INTERNATIONAL CONFERENCE ON INTERNET OF THINGS (ITHINGS) AND IEEE GREEN COMPUTING AND COMMUNICATIONS (GREENCOM) AND IEEE CYBER, PHYSICAL AND SOCIAL COMPUTING (CPSCOM) AND IEEE SMART DATA (SMARTDATA), 2017, : 917 - 924