The accuracy of computerized biophotogrammetry in diagnosing changes in the cervical spine and its reliability for the cervical lordosis angle

被引:0
|
作者
Nascimento Martins de Albuquerque, Priscila Maria [1 ]
de Oliveira, Daniella Araujo [1 ]
do Nascimento Alves, Laura Izabel [1 ]
da Silva Alves Gomes, Vanessa Maria [1 ]
Reboucas Bezerra, Laylla Marjorye [1 ]
de Souza Melo, Thania Maion [1 ]
de Alencar, Geisa Guimaraes [1 ]
Tenorio, Angelica da Silva [1 ]
de Siqueira, Gisela Rocha [1 ]
机构
[1] Univ Fed Pernambuco, Dept Physiotherapy, Recife, PE, Brazil
关键词
Cervical vertebrae; data accuracy; posture; photogrammetry; radiography; POSTURE; PHOTOGRAMMETRY; RADIOGRAPHY; ALIGNMENT;
D O I
10.3233/BMR-210375
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: Accuracy studies of biophotogrammetry protocols require standardization similar to radiography. OBJECTIVE: To estimate the diagnostic accuracy of a biophotogrammetric assessment protocol for cervical hyperlordosis, compared to radiography, and its intra- and inter-examiner reliability for measuring the cervical lordosis angle. METHODS: A study of diagnostic accuracy in women complaining of cervical pain. Two photos were taken using the Corel-Draw biophotogrammetric protocol and one radiograph using the Cobb C1-C7 method. The Intra- and Inter-examiner reliability was calculated using the Kappa index and the intraclass correlation coefficient (ICC). The Bland-Altman plot and the ROC curve were presented. RESULTS: The sample consisted of 19 women. The accuracy of biophotogrammetry was 94.73% and the reliability between biophotogrammetry and radiography presented an ICC of 0.84 and a Kappa of 0.87. The excellent intra (ICC = 0.94) and inter-examiner (ICC = 0.86) reliability of the biophotogrammetry was confirmed. The area under the ROC curve was 93.5%. The Bland-Altman plot indicated differences between the two instruments close to the mean (1.5 degrees). CONCLUSION: The biophotogrammetric protocol proved to be accurate in diagnosing cervical hyperlordosis, with excellent reliability between the biophotogrammetric and radiographic assessments. It also demonstrated excellent intra- and inter-examiner reliability in measuring the cervical lordosis angle.
引用
收藏
页码:187 / 198
页数:12
相关论文
共 50 条
  • [31] Reliability of movement control tests on the cervical spine
    Maja Patroncini
    Susanne Hannig
    André Meichtry
    Hannu Luomajoki
    BMC Musculoskeletal Disorders, 15
  • [32] Reliability of Movement Control Tests on the Cervical Spine
    Patroncini, M.
    Hannig, S.
    Meichtry, A.
    PHYSIOSCIENCE, 2018, 14 (02) : 95 - 96
  • [33] CERVICAL-SPINE CHANGES IN GOITERS
    KOMOLAFE, F
    CLINICAL RADIOLOGY, 1982, 33 (01) : 25 - 29
  • [34] CERVICAL SPINE CHANGES IN ARTHRITIS WITH PSORIASIS
    ESTRIN, IJ
    ARTHRITIS AND RHEUMATISM, 1963, 6 (03): : 268 - &
  • [35] PATTERNS OF CHANGES IN CERVICAL SPINE ON LATEROFLEXION
    JIROUT, J
    NEURORADIOLOGY, 1971, 2 (03) : 164 - &
  • [36] TREATMENT OF CHANGES IN THE CERVICAL-SPINE
    VANDORSSER, AHD
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (04): : 480 - 480
  • [37] Mechanisms of compensatory for cervical lordosis changes after laminectomy with fusion
    Kai Yang
    Xiang-Yu Li
    Yu Wang
    Chao Kong
    Shi-Bao Lu
    BMC Surgery, 22
  • [38] Reliability of the visual assessment of cervical and lumbar lordosis: How good are we?
    Fedorak, C
    Ashworth, N
    Marshall, J
    Paull, H
    SPINE, 2003, 28 (16) : 1857 - 1859
  • [39] Reliability of cervical lordosis measurement techniques on long-cassette radiographs
    Janusz, Piotr
    Tyrakowski, Marcin
    Yu, Hailong
    Siemionow, Kris
    EUROPEAN SPINE JOURNAL, 2016, 25 (11) : 3596 - 3601
  • [40] Reliability of cervical lordosis measurement techniques on long-cassette radiographs
    Piotr Janusz
    Marcin Tyrakowski
    Hailong Yu
    Kris Siemionow
    European Spine Journal, 2016, 25 : 3596 - 3601