Pancreatic cancer detection with dual-energy CT: diagnostic performance of 40 keV and 70 keV virtual monoenergetic images

被引:3
|
作者
Noda, Yoshifumi [1 ]
Ando, Tomohiro [1 ]
Kaga, Tetsuro [1 ]
Yamda, Nao [1 ]
Seko, Takuya [1 ]
Ishihara, Takuma [2 ]
Kawai, Nobuyuki [1 ]
Miyoshi, Toshiharu [3 ]
Ito, Akio [1 ]
Naruse, Takuya [1 ]
Hyodo, Fuminori [4 ,6 ]
Kato, Hiroki [1 ]
Kambadakone, Avinash R. [5 ]
Matsuo, Masayuki [1 ]
机构
[1] Gifu Univ, Dept Radiol, 1-1 Yanagido, Gifu 5011194, Japan
[2] Gifu Univ Hosp, Innovat & Clin Res Promot Ctr, 1-1 Yanagido, Gifu 5011194, Japan
[3] Gifu Univ Hosp, Dept Radiol Serv, 1-1 Yanagido, Gifu 5011194, Japan
[4] Gifu Univ, Inst Adv Study, Ctr One Med Innovat Translat Res Com, 1-1 Yanagido, Gifu 5011194, Japan
[5] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, 55 Fruit St,White 270, Boston, MA 02114 USA
[6] Gifu Univ, Grad Sch Med, Dept Pharmacol, Gifu, Japan
来源
RADIOLOGIA MEDICA | 2024年 / 129卷 / 05期
关键词
Dual-energy computed tomography; Pancreatic cancer; Digestive system diagnostic technics; Virtual monoenergetic images; ADENOCARCINOMA;
D O I
10.1007/s11547-024-01806-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To compare the diagnostic performance of 40 keV and 70 keV virtual monoenergetic images (VMIs) generated from dual-energy CT in the detection of pancreatic cancer. Methods This retrospective study included patients who underwent pancreatic protocol dual-energy CT from January 2019 to August 2022. Four radiologists (1-11 years of experience), who were blinded to the final diagnosis, independently and randomly interpreted 40 keV and 70 keV VMIs and graded the presence or absence of pancreatic cancer. For each image set (40 keV and 70 keV VMIs), the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated. The diagnostic performance of each image set was compared using generalized estimating equations. Results Overall, 137 patients (median age, 71 years; interquartile range, 63-78 years; 77 men) were included. Among them, 62 patients (45%) had pathologically proven pancreatic cancer. The 40 keV VMIs had higher specificity (75% vs. 67%; P < .001), PPV (76% vs. 71%; P < .001), and accuracy (85% vs. 81%; P = .001) than the 70 keV VMIs. On the contrary, 40 keV VMIs had lower sensitivity (96% vs. 98%; P = .02) and NPV (96% vs. 98%; P = .004) than 70 keV VMIs. However, the diagnostic confidence in patients with (P < .001) and without (P = .001) pancreatic cancer was improved in 40 keV VMIs than in 70 keV VMIs. Conclusions The 40 keV VMIs showed better diagnostic performance in diagnosing pancreatic cancer than the 70 keV VMIs, along with higher reader confidence.
引用
收藏
页码:677 / 686
页数:10
相关论文
共 50 条
  • [41] Low-iodine 40-keV virtual monoenergetic CT angiography of the lower extremities
    Fahrni, Guillaume
    Mingas, Thomas
    Deliessche, Arthur
    Hraichi, Smail
    Rotzinger, David C.
    Si-Mohamed, Salim A.
    Boccalini, Sara
    Douek, Philippe
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [42] Virtual monoenergetic images from dual-energy CT: systematic assessment of task-based image quality performance
    Cester, Davide
    Eberhard, Matthias
    Alkadhi, Hatem
    Euler, Andre
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 726 - +
  • [43] Carotid dual-energy CT angiography: Evaluation of low keV calculated monoenergetic datasets by means of a frequency-split approach for noise reduction at low keV levels
    Riffel, Philipp
    Haubenreisser, Holger
    Meyer, Mathias
    Sudarski, Sonja
    Morelli, John N.
    Schmidt, Bernhard
    Schoenberg, Stefan O.
    Henzler, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (04) : 720 - 725
  • [44] Virtual monoenergetic dual-energy CT for evaluation of hepatic and splenic lacerations
    Sun, Ellen X.
    Wortman, Jeremy R.
    Uyeda, Jennifer W.
    Lacson, Roger
    Sodickson, Aaron D.
    EMERGENCY RADIOLOGY, 2019, 26 (04) : 419 - 425
  • [45] Virtual monoenergetic dual-energy CT for evaluation of hepatic and splenic lacerations
    Ellen X. Sun
    Jeremy R. Wortman
    Jennifer W. Uyeda
    Roger Lacson
    Aaron D. Sodickson
    Emergency Radiology, 2019, 26 : 419 - 425
  • [46] Impact of Phantom Size on Low-Energy Virtual Monoenergetic Images of Three Dual-Energy CT Platforms
    Greffier, Joel
    Van Ngoc Ty, Claire
    Fitton, Isabelle
    Frandon, Julien
    Beregi, Jean-Paul
    Dabli, Djamel
    DIAGNOSTICS, 2023, 13 (19)
  • [47] Determination of the optimal range for virtual monoenergetic images in dual-energy CT based on physical quality parameters
    Fernandez-Velilla Cepria, Enric
    Angel Gonzalez-Ballester, Miguel
    Quera Jordana, Jaume
    Pera, Oscar
    Sanz Latiesas, Xavier
    Foro Arnalot, Palmira
    Membrive Conejo, Ismael
    Rodriguez de Dios, Nuria
    Reig Castillejo, Anna
    Algara Lopez, Manuel
    MEDICAL PHYSICS, 2021, 48 (09) : 5085 - 5095
  • [48] Proton stopping power prediction based on dual-energy CT-generated virtual monoenergetic images
    Nasmark, Torbjorn
    Andersson, Jonas
    MEDICAL PHYSICS, 2021, 48 (09) : 5232 - 5243
  • [50] Noise-Optimized Virtual Monoenergetic Dual-Energy CT Improves Diagnostic Accuracy for the Detection of Active Arterial Bleeding of the Abdomen
    Martin, Simon S.
    Wichmann, Julian L.
    Scholtz, Jan-Erik
    Leithner, Doris
    D'Angelo, Tommaso
    Weyer, Hendrik
    Booz, Christian
    Lenga, Lukas
    Vogl, Thomas J.
    Albrecht, Moritz H.