Studying the imaging features and infarction mechanism of vertebrobasilar dolichoectasia with high-resolution magnetic resonance imaging

被引:9
|
作者
Zheng, Tao [1 ]
Tang, Wenxiong [2 ]
Shan, Yi [2 ,3 ]
Guo, Runcai [4 ]
Gao, Yang [2 ]
Tian, Chaohui [2 ]
Liu, Lei [2 ]
Sun, Lili [2 ]
Liu, Wei [2 ]
Zhou, Zhi [2 ]
Jin, Yi [2 ]
Duan, Shaojie [2 ]
Han, Bingyu [2 ]
Fang, Yangyi [1 ,6 ]
Zhu, Xianjin [5 ]
Liu, Zunjing [1 ,6 ]
机构
[1] Peking Univ Peoples Hosp, Dept Neurol, Beijing, Peoples R China
[2] China Japan Friendship Hosp, Dept Neurol, Beijing, Peoples R China
[3] Peking Union Med Coll, Grad Sch, Beijing, Peoples R China
[4] China Japan Friendship Hosp, Dept Radiol, Beijing, Peoples R China
[5] Capital Med Univ, Beijing Friendship Hosp, Dept Neurol, Beijing, Peoples R China
[6] Peking Univ Peoples Hosp, Dept Neurol, 11 Xizhimen South St, Beijing 100044, Peoples R China
基金
中国国家自然科学基金;
关键词
high-resolution MRI; imaging features; infarction mechanism; Vertebrobasilar dolichoectasia; DIGITAL-SUBTRACTION-ANGIOGRAPHY; STROKE;
D O I
10.1111/bpa.13135
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The mechanisms underlying ischemic infarction in patients with vertebrobasilar dolichoectasia (VBD) remain unclear. In this study, we retrospectively analyzed the imaging characteristics of high-resolution magnetic resonance imaging (HR-MRI) in patients with VBD to explore the possible mechanisms of ischemic stroke (IS) in patients with VBD. Patients with VBD were recruited from the HR-MRI database between July 2017 and June 2021. HR-MRI was used to evaluate the diameter, bifurcation height, laterality, arterial dissection, and atherosclerotic plaques of the basilar artery (BA). Transcranial Doppler was used to measure the vertebrobasilar mean velocity (Vm), peak systolic velocity (Vs), end-diastolic velocity (Vd), and pulsatile index. Twenty-six patients with VBD were enrolled, of which 15 had IS and 11 did not. The incidence of classical vascular risk factors, including age, sex, hypertension, diabetes, and hypercholesterolemia, did not differ significantly between the two groups. The BA diameters of the stroke group were significantly higher than that of the nonstroke group (6.57 +/- 1.00 mm vs. 5.06 +/- 0.50 mm, p = 0.000). The height of the BA bifurcation in the stroke and nonstroke groups was statistically significant (p = 0.002). Compared with the nonstroke group, the Vm, Vs, and Vd of the BA in the stroke group were lower, but the difference was not significant. In the 16 patients with atherosclerotic stenosis, 30 atherosclerotic plaques were found in the BA, 18 (60%) in the greater curvature, and 12 (40%) in the lesser curvature. In addition, one artery dissection (on the lesser curvature) and two dissecting aneurysms (on the greater curvature) were found in the BA of three patients, respectively. The BA diameter and bifurcation height are factors related to IS in patients with VBD. The mechanism of stroke in patients with VBD may involve abnormal hemodynamics, artery dissection, and atherosclerosis. HR-MRI is a useful method for evaluating the risk and underlying mechanism of stroke in patients with VBD.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING OF THE BRAIN IN CHILDREN
    DUBOWITZ, LMS
    PENNOCK, JM
    JOHNSON, MA
    BYDDER, GM
    CLINICAL RADIOLOGY, 1986, 37 (02) : 113 - 117
  • [32] High-resolution venography of the brain using magnetic resonance imaging
    Jürgen R. Reichenbach
    Marco Essig
    E. Mark Haacke
    Benjamin C. Lee
    Christian Przetak
    Werner A. Kaiser
    Lothar R. Schad
    Magnetic Resonance Materials in Physics, Biology and Medicine, 1998, 6 (1) : 62 - 69
  • [33] The neuroscientific exploitation of high-resolution functional magnetic resonance imaging
    Kriegeskorte, Nikolaus
    Bandettini, Peter
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 6228 - +
  • [34] High-resolution functional magnetic resonance imaging of the animal brain
    Kim, SG
    Ugurbil, K
    METHODS, 2003, 30 (01) : 28 - 41
  • [35] High-resolution magnetic resonance imaging for the assessment of hand osteoarthritis
    Tan, AL
    Grainger, AJ
    Tanner, SF
    Shelley, DM
    Pease, C
    Emery, P
    McGonagle, D
    ARTHRITIS AND RHEUMATISM, 2005, 52 (08): : 2355 - 2365
  • [36] Clinical applications of high-resolution ocular magnetic resonance imaging
    Keizo Tanitame
    Takashi Sone
    Yoshiaki Kiuchi
    Kazuo Awai
    Japanese Journal of Radiology, 2012, 30 : 695 - 705
  • [37] High-resolution magnetic resonance imaging of the normal extraocular musculature
    Ettl, A
    Kramer, J
    Daxer, A
    Koornneef, L
    EYE, 1997, 11 (6) : 793 - 797
  • [38] HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING OF THE TEMPORAL BONE
    JAGER, LJ
    MULLERLISSE, U
    REISER, M
    GREVERS, G
    LARYNGO-RHINO-OTOLOGIE, 1994, 73 (07) : 385 - 389
  • [39] High-resolution magnetic resonance imaging of the normal extraocular musculature
    A Ettl
    J Kramer
    A Daxer
    L Koornneef
    Eye, 1997, 11 : 793 - 797
  • [40] High-resolution magnetic resonance imaging for detection of carotid plaques
    Honda, M
    Kitagawa, N
    Tsutsumi, K
    Nagata, I
    Morikawa, M
    Hayashi, T
    NEUROSURGERY, 2006, 58 (02) : 338 - 344