Position-sensitive hybrid particle detector based on discrete-time readout

被引:0
|
作者
Masoliver, Pavel [1 ]
Abusleme, Angel [1 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Elect Engn, Ave Vicuna Mackenna 4860, Santiago 7820436, Chile
关键词
Scintillating detector; Position-sensitive detector; Discrete-time readout; SPATIAL-RESOLUTION; OF-FLIGHT;
D O I
10.1016/j.nima.2024.169121
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this work a new readout scheme for scintillator-based detectors, using discrete time differences through a delay line is proposed, reducing the readout channels while maintaining the spatial resolution. A prototype was built using plastic scintillator blocks and MPPC sensors. Currently, the prototype produces discrete distributions with a dispersion < 1.1 ns which allows discriminating the different positions. The estimated spatial resolution is sigma = 1.456 mm. This value presents a better resolution than that of Time-of-Flight detectors and of the order of Segmented detectors, but uses fewer readout channels. It is expected to improve this resolution using interpolation effects and testing with larger scale instruments.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] A HIGH-TIME-RESOLUTION POSITION-SENSITIVE RADIATION DETECTOR
    GAVALIAN, VG
    LORIKIAN, MP
    SHIKHLIAROV, KK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 337 (2-3): : 613 - 614
  • [32] High-time-resolutions position-sensitive radiation detector
    Gavalian, V.G.
    Lorikian, M.P.
    Shikhliarov, K.K.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A337 (2-3) : 613 - 614
  • [33] A LARGE POSITION-SENSITIVE NEUTRON DETECTOR
    NETTER, P
    LASSEN, L
    SCHRECK, R
    GEMMEKE, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 185 (1-3): : 165 - 174
  • [34] PERFORMANCE OF A POSITION-SENSITIVE BAR DETECTOR
    KARP, JS
    MUEHLLEHNER, G
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (05) : P47 - P47
  • [35] Position-sensitive CZT detector module
    Matteson, JL
    Duttweiler, F
    Huszar, GL
    Leblanc, PC
    Skelton, RT
    Stephan, EA
    Hink, PL
    Dowkontt, PF
    Slavis, KR
    Tümer, TO
    Kravis, SD
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS AND APPLICATIONS, 1998, 3446 : 192 - 201
  • [36] Amorphous silicon position-sensitive detector
    Mochiki, Koh-ichi
    Hasegawa, Ken-ichi
    Namatame, Shuji
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 640 - 644
  • [37] PROPOSAL FOR A POSITION-SENSITIVE PHOTOMULTIPLIER DETECTOR
    PRYDZ, S
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1973, 6 (02): : 189 - 190
  • [38] A COMPACT POSITION-SENSITIVE DETECTOR FOR PET
    WATANABE, M
    OMURA, T
    KYUSHIMA, H
    HASEGAWA, Y
    YAMASHITA, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1090 - 1094
  • [39] POSITION-SENSITIVE SUPERCONDUCTING RADIATION DETECTOR
    VASILEVICH, AF
    KLYACHIN, NA
    LYAPIDEVSKII, VK
    PEREZHOGIN, VB
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1979, 22 (02) : 376 - 377
  • [40] RADIAL POSITION-SENSITIVE SEMICONDUCTOR DETECTOR
    AMOV, B
    DZHAKOV, A
    OSIPENKO, BP
    PENTSYA, E
    SANDUKOVSKII, VG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1985, 28 (03) : 561 - 563