Study on the effect of burial depth on seismic response and seismic intensity measure of underground structures

被引:17
|
作者
Xu, Zigang [1 ,2 ]
Zhuang, Haiyang [1 ,2 ]
Xia, Zongyao [1 ,2 ]
Yang, Jing [3 ]
Bu, Xiangbo [4 ]
机构
[1] East China Jiaotong Univ, Jiangxi Key Lab Infrastruct Safety Control Geotech, Nanchang, Peoples R China
[2] East China Jiaotong Univ, Engn Res & Dev Ctr Underground Technol Jiangxi Pro, Nanchang, Peoples R China
[3] Nanjing Tech Univ, Nanjing, Peoples R China
[4] Tech Univ Catalonia, Civil & Environm Engn Dept, Barcelona, Spain
基金
中国国家自然科学基金;
关键词
Burial depth; Seismic response; Seismic intensity measure; Peak ground acceleration; Structural side soil relative displacement; PLASTIC-DAMAGE MODEL; DEMAND MODELS; PARAMETERS; TUNNELS; SOILS;
D O I
10.1016/j.soildyn.2023.107782
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Considering the complexity of the soil-structure dynamic interaction mechanism, underground structures are restrained and influenced by the surrounding soil in earthquakes, and their seismic damage under strong earthquakes is different from that of above-ground structures. The seismic response of underground structures is influenced by several coupling factors, including structural form, ground motion parameters, and soil properties, etc. In addition, the burial depth of the underground structure is also one of the critical parameters affecting its seismic response. In this study, the computational model of soil-structure dynamic interaction at different burial depths was established by using the finite element software ABAQUS with a single-story, double-span Daikai subway station as the prototype. The influence laws of different burial depth conditions on the seismic response characteristics such as inter-story drift ratio, internal force of critical sections, and seismic damage of subway stations are systematically studied. Meanwhile, this paper compares the correlation and applicability of PGA (peak ground acceleration), PSSRD (peak site soil relative displacement), and SSSRD (structural side soil relative displacement) with the seismic response of underground structures under different burial depths by applying the principle of vulnerability analysis. The results show that PGA and SSSRD are relatively better IMs (intensity measure) in shallowly buried structures, while the relative superiority of PSSRD gradually increases with increasing burial depth, and PSSRD is a more reasonable IM in deeply buried underground structures.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Seismic design and analysis of underground structures
    Hashash, YMA
    Hook, JJ
    Schmidt, B
    Yao, JIC
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2001, 16 (04) : 247 - 293
  • [32] Seismic analysis of underground structures employing extended response spectrum method
    Gao, Zhidong
    Zhao, Mi
    Du, Xiuli
    Naggar, M. Hesham El
    Wang, Junjie
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 116
  • [33] Improved equivalent response acceleration method for seismic design of underground structures
    Yu Hai-tao
    Zhang Zheng-wei
    Li Pan
    ROCK AND SOIL MECHANICS, 2020, 41 (07) : 2401 - 2410
  • [34] Seismic performance indicator and seismic performance levels of rectangular underground structures
    Bao, Xin
    Liu, Jingbo
    Wang, Wenhui
    Lu, Xihuan
    STRUCTURES, 2022, 41 : 117 - 127
  • [35] Evaluating Impact of Adjacent Tall Buildings on Seismic Response of Underground Structures
    Basarah, Yuamar I.
    Numanoglu, Ozgun A.
    Hashash, Youssef M. A.
    LIFELINES 2022: ADVANCING LIFELINE ENGINEERING FOR COMMUNITY RESILIENCE, 2022, : 207 - 215
  • [36] Theoretical and Numerical Analysis on the Seismic Response of Underground Structures in Existence of Isolators
    Liu, Jinchun
    Huan, Yi
    ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6, 2012, 368-373 : 710 - 714
  • [37] Efficient hybrid simulation method for seismic response analysis of underground structures
    Yu H.
    Wang Z.
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2024, 46 (01): : 45 - 53
  • [38] Improved response displacement method for evaluating seismic responses of underground structures
    Li, Liang
    Yang, Xiao-Hui
    Du, Xiu-Li
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2014, 36 (07): : 1360 - 1364
  • [39] Analysis on the Influence of Increasing Seismic Fortification Intensity on Seismic Performance of Underground Station
    Zeng, Ying
    Xu, Shiguang
    Yin, Shiqian
    ADVANCES IN CIVIL ENGINEERING, 2021, 2021
  • [40] Seismic intensity measure in consideration of nonlinear response of reinforced concrete columns
    Matsuzaki, H.
    Kasahara, K.
    Nemoto, K.
    Suzuki, M.
    LIFE-CYCLE OF STRUCTURAL SYSTEMS: DESIGN, ASSESSMENT, MAINTENANCE AND MANAGEMENT, 2015, : 1771 - 1778