Direct numerical simulation of contaminant removal in presence of underfloor air distribution system

被引:1
|
作者
Xia, Yaowen [1 ,2 ]
Lyu, Saidong [1 ,2 ]
机构
[1] Yunnan Normal Univ, Key Lab Rural Energy Engn Yunnan, Kunming 650092, Yunnan, Peoples R China
[2] Yunnan Normal Univ, Solar Energy Res Inst, Kunming 650092, Yunnan, Peoples R China
基金
中国国家自然科学基金;
关键词
Ventilation effectiveness; Contaminant removal; COVID-19; Direct numerical simulation; DIFFUSIVE NATURAL-CONVECTION; THERMAL COMFORT; ENERGY; CAVITY; TEMPERATURE; MODEL;
D O I
10.1016/j.heliyon.2024.e24331
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Indoor contaminant removal over 0.5 <= FrT <= 5.0, 0.5 <= N <= 5.0, and 50 <= Re <= 500 was investigated numerically, wherein FrT refers to the Froude number, N refers to the buoyancy ratio, and Re refers to the Reynolds number. As demonstrated, the ventilation effectiveness increased with increasing contaminant source intensity and air supply intensity at a constant air temperature, indicating that increase the fresh air can effectively eliminate contaminants in this case. At high air supply temperatures, the heat retention time and contaminant transport was extremely short, and the fresh air induced by strong natural convection floating lift was rapidly discharged. Additioanlly, the air supply intensity had significant effects on contaminant removal. Quantification of the ventilation effectiveness under the combined effects of air supply intensity, air supply temperature and contaminant source intensity was determined based on the results of direct numerical simulations.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Numerical simulation transient electron distribution of direct current negative corona discharge in air
    Liu, Xinghua
    Xian, Richang
    Yu, Peng
    Pei, Ying
    Lv, Xuebin
    Sun, Xuefeng
    Wang, Tao
    Ning, Shangyuan
    Wang, Shikun
    2017 INTERNATIONAL SYMPOSIUM ON RESOURCE EXPLORATION AND ENVIRONMENTAL SCIENCE (REES 2017), 2017, 64
  • [32] Overall performance evaluation of underfloor air distribution system with different heights of return vents
    Fan, Yaming
    Li, Xiangdong
    Yan, Yihuan
    Tu, Jiyuan
    ENERGY AND BUILDINGS, 2017, 147 : 176 - 187
  • [33] Saving energy by using underfloor-air-distribution (UFAD) system in commercial buildings
    Alajmi, Ali
    El-Amer, Wid
    ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (08) : 1637 - 1642
  • [34] Study of underfloor air distribution using zonal model-based simulation and experimental measurements
    Fang, Hong
    Zhao, Dongliang
    Tan, Gang
    Denzer, Anthony
    ENERGY AND BUILDINGS, 2017, 152 : 96 - 107
  • [35] Energy Benefit of the Underfloor Air Distribution System for Reducing Air-Conditioning and Heating Loads in Buildings
    Lim, Tae Sub
    Schaefer, Laura
    Kim, Jeong Tai
    Kim, Gon
    INDOOR AND BUILT ENVIRONMENT, 2012, 21 (01) : 62 - 70
  • [36] CFD simulation of airflows and ammonia emissions in a pig compartment with underfloor air distribution system: Model validation at different ventilation rates
    Tabase, Raphael Kubeba
    Van Linden, Veerle
    Bagci, Ozer
    De Paepe, Michel
    Aarnink, Andre J. A.
    Demeyer, Peter
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2020, 171
  • [37] Thermal decay in underfloor air distribution (UFAD) systems: Fundamentals and influence on system performance
    Lee, Kwang Ho
    Schiavon, Stefano
    Bauman, Fred
    Webster, Tom
    APPLIED ENERGY, 2012, 91 (01) : 197 - 207
  • [38] Multi-objective optimization of underfloor air distribution (UFAD) systems performance in a densely occupied environment: A combination of numerical simulation and Taguchi algorithm
    Shokrollahi, Samaneh
    Hadavi, Mohammad
    Heidarinejad, Ghassem
    Pasdarshahri, Hadi
    JOURNAL OF BUILDING ENGINEERING, 2020, 32
  • [39] Fast flow simulation study of pulsating ventilation performance on air contaminant removal
    Zhou, Pengzhi
    Wang, Haidong
    Dai, Yuwei
    Huang, Chen
    BUILDING SIMULATION, 2024, 17 (08) : 1309 - 1322
  • [40] Numerical Simulation on Air dispersion of the Fabric Air Distribution System in Pure-Penetration Mode
    Chen, Fujiang
    Chen, Huanxin
    Xie, Junlong
    Shu, Zhaohui
    Hu, Yunpeng
    Mao, Jiani
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 891 - 898