Effects of Ion Concentration on Ion Current Rectification Using a Glass Nanocapillary

被引:0
|
作者
Ito, Chisato [1 ]
Ino, Kosuke [2 ]
Hiramoto, Kaoru [3 ]
Nashimoto, Yuji [4 ]
Shiku, Hitoshi [1 ,2 ]
机构
[1] Tohoku Univ, Grad Sch Environm Studies, 6-6-11 Aoba,Aoba Ku, Sendai, Miyagi 9808579, Japan
[2] Tohoku Univ, Grad Sch Engn, 6-6-11 Aoba,Aoba Ku, Sendai, Miyagi 9808579, Japan
[3] Tohoku Univ, Frontier Res Inst Interdisciplinary Sci, 2-1-1 Katahira,Aoba Ku, Sendai, Miyagi 9808577, Japan
[4] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, 2-3-10 Kanda Surugadai,Chiyoda Ku, Tokyo 1010062, Japan
关键词
ion current rectification; glass nanocapillary; nanopore;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
When a glass capillary with a nanopore at its tip is filled with a solution of low ion concentration, the ion concentration at the tip is higher than expected. This is because the ions form an electrical double layer inside the wall. In this case, the ion currents conducted via the nanopore differ dramatically depending on the polarity of the applied potential. This phenomenon is known as ion current rectification (ICR). ICR shows great potential for applications in bioassay methodology, as it is heavily influenced by the amount of surface charges on the inside wall of the nanopore, allowing it to be seamlessly applied in biosensing procedures. However, ICR can only be induced under low ion concentrations, preventing it from being applied for biosensing under physiological conditions. To address this issue, the effects of the ion concentration of phosphate buffer solutions (PBS) in a glass nanocapillary and bulk outside of the capillary on ICR were investigated in this study. Three ion concentrations were introduced into the capillary and the bulk, and ion current via the nanopore was measured. The results show that ICR was successfully monitored even though PBS of a physiological condition was used in either the glass nanocapillary or bulk. In addition, cell spheroids were monitored inside the capillary as a preliminary study for biosensing. This finding can be utilized for ICR-based biosensing applications under a physiological condition.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 50 条
  • [21] Ion current rectification: from nanoscale to microscale
    Tianyi Xiong
    Kailin Zhang
    Yanan Jiang
    Ping Yu
    Lanqun Mao
    Science China(Chemistry) , 2019, (10) : 1346 - 1359
  • [22] Ion current rectification: from nanoscale to microscale
    Tianyi Xiong
    Kailin Zhang
    Yanan Jiang
    Ping Yu
    Lanqun Mao
    Science China Chemistry, 2019, 62 : 1346 - 1359
  • [23] Ion current rectification: from nanoscale to microscale
    Tianyi Xiong
    Kailin Zhang
    Yanan Jiang
    Ping Yu
    Lanqun Mao
    Science China(Chemistry), 2019, 62 (10) : 1346 - 1359
  • [24] Ion current rectification in funnel-shaped nanochannels: Hysteresis and inversion effects
    Rosentsvit, Leon
    Wang, Wei
    Schiffbauer, Jarrod
    Chang, Hsueh-Chia
    Yossifon, Gilad
    JOURNAL OF CHEMICAL PHYSICS, 2015, 143 (22):
  • [25] Ion-current-rectification-based customizable pH response in glass nanopipettes via silanization
    Liu, Guo-Chang
    Chen, Wei
    Gao, Meng-Juan
    Song, Lai-Bo
    Hu, Xiao-Yu
    Zhao, Yuan-Di
    ELECTROCHEMISTRY COMMUNICATIONS, 2018, 93 : 95 - 99
  • [26] pH-modulated ion-current rectification in a cysteine-functionalized glass nanopipette
    Liu, Guo-Chang
    Gao, Meng-Juan
    Chen, Wei
    Hu, Xiao-Yu
    Song, Lai-Bo
    Liu, Bo
    Zhao, Yuan-Di
    ELECTROCHEMISTRY COMMUNICATIONS, 2018, 97 : 6 - 10
  • [27] Ion current rectification in asymmetric nanochannels: effects of nanochannel shape and surface charge
    Qiao, Nan
    Zhang, Zhe
    Liu, Zheng
    Lu, Wei
    Li, Changzheng
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 208
  • [28] SERIES ARRAYS OF ION-EXCHANGE MEMBRANES - CONCENTRATION PROFILES AND RECTIFICATION OF ELECTRIC-CURRENT
    NAPARSTEK, A
    CAPLAN, SR
    KATZIRKA.A
    ISRAEL JOURNAL OF CHEMISTRY, 1973, 11 (2-3) : 255 - 270
  • [29] Electrostatic effects on ion selectivity and rectification in designed ion channel peptides
    Lear, JD
    Schneider, JP
    Kienker, PK
    DeGrado, WF
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (14) : 3212 - 3217
  • [30] Effect of Conical Nanopore Diameter on Ion Current Rectification
    Kovarik, Michelle L.
    Zhou, Kaimeng
    Jacobson, Stephen C.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2009, 113 (49): : 15960 - 15966