PERFORMANCE OF A GUIDED WAVE PIPE MONITORING SYSTEM OVER EXTENDED PERIODS OF FIELD OPERATION

被引:3
|
作者
Mariani, Stefano [1 ]
Heinlein, Sebastian [1 ]
Vogt, Thomas [1 ]
Cawley, Peter [1 ,2 ]
机构
[1] Guided Ultrason Ltd, London TW8 8HQ, England
[2] Imperial Coll, London SW7 2AZ, England
关键词
guided wave; monitoring; permanently installed; pipes; corrosion; stability; FUNDAMENTAL TORSIONAL MODE; REFLECTION;
D O I
10.32548/2023.me-04335
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The performance of a permanently installed guided wave pipe monitoring system over extended periods has been investigated. Other than at a clamped support, the signals obtained in the three installations reported here have been stable to better than 1% (-40 dB) over periods of 12-24 months, even in hostile oil and gas facility environments. The use of baseline subtraction means that the sensitivity to defects is substantially better than that obtained in one-off inspection; in the two site examples reported here, improvements of 7 and 12 dB relative to one-off interpretation of the A-scan signal were obtained, and changes can be flagged automatically. The improvement in sensitivity is even larger at features such as welds and bends, which give significant reflections even in the absence of damage. The permanently installed system combines long-range guided wave monitoring for localized corrosion patches with eight precise thickness measurements around the pipe circumference, making it possible to monitor the general wall loss rate, as well as detect any more severe, localized corrosion. Permanently installed guided wave monitoring systems are therefore found to be a commercially attractive tool for the assessment of current and future piping integrity. KEYWORDS: guided wave, monitoring, permanently installed,
引用
收藏
页码:36 / 46
页数:11
相关论文
共 50 条
  • [31] Design of guided wave magnetostrictive patch transducer with vertical static bias magnetic field for pipe inspection
    Wang, Shujuan
    Liang, Qi
    Li, Ce
    Li, Zhichao
    Li, Yongqian
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 376
  • [32] Hardware and Software System of the Guided Wave Pipe Testing Using Electromagnetic-Acoustic Transformation
    Lenkov, S. V.
    Zverev, N. N.
    Muravieva, O. V.
    Myshkin, Yu. V.
    2016 INTERNATIONAL SIBERIAN CONFERENCE ON CONTROL AND COMMUNICATIONS (SIBCON), 2016,
  • [33] Long range ultrasonic guided wave focusing in pipe using a phased-array system
    Mu, Jing
    Rose, Joseph L.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 26A AND 26B, 2007, 894 : 158 - +
  • [34] Guided ultrasonic wave tomography of a pipe bend exposed to environmental conditions: A long-term monitoring experiment
    Simonetti, F.
    Alqaradawi, M. Y.
    NDT & E INTERNATIONAL, 2019, 105 : 1 - 10
  • [35] Performance Modelling of Automatic Identification System with Extended Field of View
    Laursen, Troels
    Mortensen, Hans Peter
    Pedersen, Nikolaj Bisgaard
    Rasmussen, Ulrik Wilken
    Madsen, Tatiana K.
    Nielsen, Jens Dalsgaard
    SMART SPACES AND NEXT GENERATION WIRED/WIRELESS NETWORKING, 2010, 6294 : 242 - 255
  • [36] High-Sensitivity Ultrasonic Guided Wave Monitoring of Pipe Defects Using Adaptive Principal Component Analysis
    Ma, Junwang
    Tang, Zhifeng
    Lv, Fuzai
    Yang, Changqun
    Liu, Weixu
    Zheng, Yinfei
    Zheng, Yang
    SENSORS, 2021, 21 (19)
  • [37] Efficient residual reliability criterion index in a permanent guided wave monitoring system
    Chen, Yon Kong
    Bakhary, Norhisham
    Padil, Khairul H.
    Shamsudin, Mohd Fairuz
    Ahmad, Arshad
    Noh , Nur Hazirah
    Norazahar, Norafneeza
    MEASUREMENT, 2022, 197
  • [38] Blind Trial Validation of a Guided Wave Structural Health Monitoring System for Pipework
    Heinlein, Sebastian
    Cawley, Peter
    Vogt, Thomas
    Burch, Stephen
    MATERIALS EVALUATION, 2018, 76 (08) : 1118 - 1126
  • [39] Optical fibre fatigue behavior over very extended periods at low stress levels in the field and in laboratory tests
    Stockton, DJ
    Mayhew, AJ
    OPTICAL FIBER RELIABILITY AND TESTING, 1999, 3848 : 44 - 54
  • [40] Piezoelectric-actuator excited-wave field solutions for guided-wave structural health monitoring
    Raghavan, A
    Cesnik, CES
    SMART STRUCTURES AND MATERIALS 2005: SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE, PTS 1 AND 2, 2005, 5765 : 313 - 323