摘要
In this paper, we propose a noise-robust pulse wave estimation method from near-infrared face video images. Pulse wave estimation in a near-infrared environment is expected to be applied to non-contact monitoring in dark areas. The conventional method cannot consider noise when performing estimation. As a result, the accuracy of pulse wave estimation in noisy environments is not very high. This may adversely affect the accuracy of heart rate data and other data obtained from pulse wave signals. Therefore, the objective of this study is to perform pulse wave estimation robust to noise. The Wiener estimation method, which is a simple linear computation that can consider noise, was used in this study. Experimental results showed that the combination of the proposed method and signal processing (detrending and bandpass filtering) increased the SNR (signal to noise ratio) by more than 2.5 dB compared to the conventional method and signal processing. The correlation coefficient between the pulse wave signal measured using a pulse wave meter and the estimated pulse wave signal was 0.30 larger on average for the proposed method. Furthermore, the AER (absolute error rate) between the heart rate measured with the pulse wave meter was 0.82% on average for the proposed method, which was lower than the value of the conventional method (12.53% on average). These results show that the proposed method is more robust to noise than the conventional method for pulse wave estimation.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] A Novel Near-Infrared Array Based Arterial Pulse Wave Measurement Method
    Huang, Wei-Chin
    Hou, Hsiang-Wen
    Cheng, Ching-Ju
    Wu, Shih-Yang
    Chen, Tien-Ho
    Fang, Wai-Chi
    2013 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2013, : 41 - 44
  • [32] NOISE-ROBUST REVERBERATION TIME ESTIMATION USING SPECTRAL DECAY DISTRIBUTIONS WITH REDUCED COMPUTATIONAL COST
    Eaton, James
    Gaubitch, Nikolay D.
    Naylor, Patrick A.
    2013 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2013, : 161 - 165
  • [33] Noise-robust blind reverberation time estimation using noise-aware time-frequency masking
    Zheng, Kaitong
    Zheng, Chengshi
    Sang, Jinqiu
    Zhang, Yulong
    Li, Xiaodong
    MEASUREMENT, 2022, 192
  • [34] Multispectral Texture Features from Visible and Near-infrared Synthetic Face Images for Face Recognition
    Kim, Hyung-Il
    Lee, Seung Ho
    Ro, Yong Man
    2015 IEEE INTERNATIONAL SYMPOSIUM ON MULTIMEDIA (ISM), 2015, : 593 - 596
  • [35] Estimating carotid pulse and breathing rate from near-infrared video of the neck
    Chen, Weixuan
    Hernandez, Javier
    Picard, Rosalind W.
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (10)
  • [36] Robust focused image estimation from multiple images in video sequences
    Yang, Junlan
    Schonfeld, Dan
    Mohamed, Magdi
    2007 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-7, 2007, : 1225 - +
  • [37] Nonstationary stochastic process-based robust estimation algorithm of near-infrared albedo
    Fang Z.-Q.
    Yu X.-S.
    Jia T.
    Wu C.-D.
    Li Y.-Q.
    Xu M.
    Kongzhi yu Juece/Control and Decision, 2019, 34 (06): : 1151 - 1159
  • [38] ESTIMATION OF SOIL-MOISTURE STATUS USING NEAR-INFRARED REFLECTANCE
    WHALLEY, WR
    LEEDSHARRISON, PB
    BOWMAN, GE
    HYDROLOGICAL PROCESSES, 1991, 5 (03) : 321 - 327
  • [39] Estimation of Muscle Fatigue Using Surface Electromyography and Near-Infrared Spectroscopy
    Taelman, Joachim
    Vanderhaegen, Joke
    Robijns, Mieke
    Naulaers, Gunnar
    Spaepen, Arthur
    Van Huffel, Sabine
    OXYGEN TRANSPORT TO TISSUE XXXII, 2011, 701 : 353 - 359
  • [40] Robust estimation of pulse wave transit time using group delay
    Meloni, Antonella
    Zymeski, Heather
    Pepe, Alessia
    Lombardi, Massimo
    Wood, John C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (03) : 550 - 558