Research Article Reference Values for Videofluoroscopic Measures of Swallowing: An Update

被引:12
|
作者
Steele, Catriona M. [1 ,2 ,3 ]
Bayley, Mark T. [1 ,3 ]
Bohn, Mary Kathryn [4 ,5 ]
Higgins, Victoria [6 ,7 ]
Peladeau-Pigeon, Melanie [1 ]
Kulasingam, Vathany [8 ]
机构
[1] Univ Hlth Network, KITE Res Inst, Toronto, ON, Canada
[2] Canada Res Chair Swallowing & Food Oral Proc, Ottawa, ON, Canada
[3] Univ Toronto, Temerty Fac Med, Toronto, ON, Canada
[4] Hosp Sick Children, Dept Pediat Lab Med, Toronto, ON, Canada
[5] Univ Toronto, Dept Lab Med & Pathobiol, Toronto, ON, Canada
[6] DynaLIFE Med Labs, Edmonton, AB, Canada
[7] Univ Alberta, Dept Lab Med & Pathol, Edmonton, AB, Canada
[8] Univ Hlth Network, Lab Med Program, Toronto, ON, Canada
来源
关键词
OROPHARYNGEAL SWALLOW; REFERENCE INTERVALS; STRUCTURAL DISPLACEMENTS; DETECTING ASPIRATION; DYSPHAGIA; PHYSIOLOGY; ADULTS; INDIVIDUALS; PENETRATION; TEXTURE;
D O I
10.1044/2023_JSLHR-23-00246
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Purpose: It is essential that clinicians have evidence-based benchmarks to support accurate diagnosis and clinical decision making. Recent studies report poor reliability for diagnostic judgments and identifying mechanisms of impairment from videofluoroscopy (VFSS). Establishing VFSS reference values for healthy swallowing would help resolve such discrepancies. Steele et al. (2019) released preliminary reference data for quantitative VFSS measures in healthy adults aged < 60 years. Here, we extend that work to provide reference percentiles for VFSS measures across a larger age span. Method: Data for 16 VFSS parameters were collected from 78 healthy adults aged 21-82 years (39 male). Participants swallowed three comfortable sips each of thin, slightly, mildly, moderately, and extremely thick barium (20% w/v). VFSS recordings were analyzed in duplicate by trained raters, blind to participant and task, using the Analysis of Swallowing Physiology: Events, Kinematics and Timing (ASPEKT) Method. Reference percentiles (p2.5, 5, 25, 50, 75, 95, and 97.5) were determined as per Clinical and Laboratory Standards Institute Results: We present VFSS reference percentile tables, by consistency, for (a) timing parameters (swallow reaction time; the hyoid burst-to-upper esophageal tibule closure (LVC); and LVC duration) and (b) anatomically scaled pixel-based measures of maximum UES diameter, pharyngeal area at maximum pharyngeal constriction and rest, residue (vallecular, pyriform, other pharyngeal locations, total), and hyoid kinematics (X, Y, XY coordinates of peak position; speed). Clinical decision limits are proposed to demarcate atypical values of potential clinical concern. Conclusion: These updated reference percentiles and proposed clinical decision limits are intended to support interpretation and reliability for VFSS assessment data.
引用
收藏
页码:3804 / 3824
页数:21
相关论文
共 50 条
  • [21] The Need to Update Reference Values for Lead in Zaragoza, Spain
    Silvia Izquierdo-Álvarez
    Maria Luisa Calvo-Ruata
    Jose Manuel González-López
    Ángel García de Jalón-Comet
    Jesús Fernando Escanero-Marcén
    Biological Trace Element Research, 2008, 123 : 277 - 280
  • [22] The need to update reference values for lead in Zaragoza, Spain
    Izquierdo-Alvarez, Silvia
    Calvo-Ruata, Maria Luisa
    Gonzalez-Lopez, Jose Manuel
    de Jalon-Comet, Angel Garcia
    Escanero-Marcen, Jesus Fernando
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2008, 123 (1-3) : 277 - 280
  • [23] Research Article Pharyngeal Pressure Variability During Volitional Swallowing Maneuvers
    Teplansky, Kristin J.
    Jones, Corinne A.
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2022, 65 (01): : 136 - 145
  • [24] Reference values versus consensus values: a reaction to the article of Baldan et al.
    Robert George Visser
    Accreditation and Quality Assurance, 2001, 6 : 442 - 443
  • [25] Reference values versus consensus values: a reaction to the article of Baldan et al.
    Visser, RG
    ACCREDITATION AND QUALITY ASSURANCE, 2001, 6 (9-10) : 442 - 443
  • [26] Pancreatic ultrasound: An update of measurements, reference values, and variations of the pancreas
    Meier, Jennifer
    Lucius, Claudia
    Moeller, Kathleen
    Jenssen, Christian
    Zervides, Constantinos
    Gschmack, Anna Maria
    Dong, Yi
    Srivastava, David
    Dietrich, Christoph F.
    ULTRASOUND INTERNATIONAL OPEN, 2024, 10
  • [27] Comment on article: King-Devick test reference values and associations with balance measures in high school American football players
    Devick, Steve
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2016, 26 (05) : 593 - 594
  • [28] Reference Values for Healthy Swallowing Across the Range From Thin to Extremely Thick Liquids
    Steele, Catriona M.
    Peladeau-Pigeon, Melanie
    Barbon, Carly A. E.
    Guida, Brittany T.
    Namasivayam-MacDonald, Ashwini M.
    Nascimento, Weslania, V
    Smaoui, Sana
    Tapson, Melanie S.
    Valenzano, Teresa J.
    Waito, Ashley A.
    Wolkin, Talia S.
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2019, 62 (05): : 1338 - 1363
  • [29] Reference Values for Physical Performance Measures in the Aging Working Population
    Cote, Mark P.
    Kenny, Anne
    Dussetschleger, Jeffrey
    Farr, Dana
    Chaurasia, Ashok
    Cherniack, Martin
    HUMAN FACTORS, 2014, 56 (01) : 228 - 242
  • [30] RETRACTED: Mycoplasmosis in poultry: update on diagnosis and preventive measures (Retracted Article)
    Umar, S.
    Munir, M. T.
    Ur-Rehman, Z.
    Subhan, S.
    Azam, T.
    Shah, M. A. A.
    WORLDS POULTRY SCIENCE JOURNAL, 2017, 73 (01) : 17 - 28