A sensitive tissue factor activity assay determined by an optimized thrombin generation method

被引:1
|
作者
Kristensen, Soren Risom [1 ,2 ]
Nybo, Jette [1 ]
机构
[1] Aalborg Univ Hosp, Dept Clin Biochem, Aalborg, Denmark
[2] Aalborg Univ, Dept Clin Med, Aalborg, Denmark
来源
PLOS ONE | 2023年 / 18卷 / 07期
关键词
FACTOR PATHWAY; PLASMA; MICROPARTICLES; COAGULATION; INHIBITOR;
D O I
10.1371/journal.pone.0288918
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
BackgroundTissue factor (TF) is the principal activator of the coagulation system, but an increased concentration in the blood in cancer and inflammatory diseases has been suggested to play a role increasing the risk of venous thromboembolism. However, measurement of the TF concentration is difficult, and quantitation of activity is the most valid estimation. The objective of this study was to establish a sensitive method to measure TF activity based on thrombin generation. MethodsThe assay is based on thrombin generation (TG) measured on the Calibrated Automated Thrombogram (CAT). Various low concentrations of TF were prepared from reagents containing 1 pM TF and 4 & mu;M phospholipid (PPL), and no TF and 4 & mu;M PPL, and a calibration curve was produced from Lagtime vs TF concentration. TF in blood samples was measured after isolation and resuspension of extracellular vesicles (EVs) in a standard plasma from which EVs had been removed. The same standard plasma was used for the calibrators. ResultsContact activation of the coagulation system was avoided using CTI plasma samples in Monovette tubes. EVs contain procoagulant phospholipids but addition of PPL only reduced lagtime slightly at very low concentrations of TF resulting in overestimation to a lesser extent at 10 fM but no interference at 30 fM or higher. Addition of EVs to the TG analysis induced a small unspecific TF-independent activity (i.e., an activity not inhibited by antibodies against TF) which also may result in a smaller error in estimation of TF activity at very low levels but the effect was negligible at higher concentrations. It was possible to measure TF activity in healthy controls which was found to be 1-6 fM (EVs were concentrated, i.e. solubilized in a lower volume than the original volume plasma). Coefficient of variation (CV) was below 20% at the low level, and below 10% at a level around 100 fM TF. However, the step with isolation of EVs have a higher inherent CV. ConclusionA sensitive and rather precise one-stage TG-based method to measure TF activity has been established.
引用
收藏
页数:15
相关论文
共 50 条
  • [11] Inhibition of tissue factor pathway inhibitor increases the sensitivity of thrombin generation assay to procoagulant microvesicles
    Gheldof, Damien
    Mullier, Francois
    Chatelain, Bernard
    Dogne, Jean-Michel
    Chatelain, Christian
    BLOOD COAGULATION & FIBRINOLYSIS, 2013, 24 (05) : 567 - 572
  • [12] Factor XII deficiency evaluated by thrombin generation assay
    Feugray, Guillaume
    Kasonga, Fiston
    Chamouni, Pierre
    Barbay, Virginie
    Fresel, Marielle
    Chretien, Marie Helene
    Brunel, Sabine
    Duchez, Eronique Le Cam
    Billoir, Paul
    CLINICAL BIOCHEMISTRY, 2022, 100 : 42 - 47
  • [13] A modified, optimized kinetic photometric thrombin generation assay components to measure the potency of thrombin in plasma
    Zrari, Salar A.
    CELLULAR AND MOLECULAR BIOLOGY, 2021, 67 (06) : 339 - 345
  • [14] A new parameter in the thrombin generation assay, mean velocity to peak thrombin, reflects factor VIII activity in patients with haemophilia A
    Takeyama, M.
    Nogami, K.
    Shima, M.
    HAEMOPHILIA, 2016, 22 (05) : E474 - E477
  • [15] The thrombin generation assay: A research method or a diagnostic test?
    Kappelmayer, J.
    Debreceni, I. Beke
    Szabo, G.
    Hudak, R.
    Toth, J.
    Bagoly, Z.
    CLINICA CHIMICA ACTA, 2019, 493 : S394 - S394
  • [16] A commentary on "A rapid, sensitive and specific assay to measure TF activity based on chromogenic determination of thrombin generation"
    Hoffman, Maureane
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2022, 20 (04) : 816 - 817
  • [17] Evaluation of ETP-mipa, a microparticle sensitive thrombin generation assay
    Molenaar, P. J.
    van Schilfgaarde, M.
    Terpstra, W. E.
    Leyte, A.
    THROMBOSIS RESEARCH, 2010, 125 : S181 - S181
  • [18] Thrombin generation assay in a patient with acquired factor V deficiency
    Radu, C.
    Gavasso, S.
    Bulato, C.
    Campello, E.
    Castoldi, E.
    Simioni, P.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 842 - 842
  • [19] Evaluation of factor xia pharmacokinetics in mice with a thrombin generation assay
    Liang, Y.
    Struble, E. B.
    Chang, W. C.
    Scott, D.
    Ovanesov, M., V
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2015, 13 : 511 - 511
  • [20] Thrombin generation assay in a patient with acquired factor V inhibitor
    Kindler, S.
    Siegemund, T.
    Fuehrer, D.
    Petros, S.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2008, 6 (11) : 1985 - 1987