Development and validation of a 'MyLyt' wearable light tracking device

被引:3
|
作者
Dhakal, Rohit [1 ,2 ,3 ]
Rudrapankte, Jagadesh Rao [4 ]
Chittajallu, Harsha S. N. S. [4 ]
Lawrenson, John G. [3 ]
Huntjens, Byki [3 ]
Shah, Rakhee [3 ]
Verkicharla, Pavan K. [1 ,2 ]
机构
[1] LV Prasad Eye Inst, Myopia Res Lab, Prof Brien Holden Eye Res Ctr, Banjara Hills, Hyderabad 500034, Telangana, India
[2] LV Prasad Eye Inst, Infor Myopia Ctr, Brien Holden Inst Optometry & Vis Sci, Hyderabad, India
[3] City Univ London, Ctr Appl Vis Res, Sch Hlth Sci, London, England
[4] LV Prasad Eye Inst, Ctr Technol Innovat, Hyderabad, India
关键词
light exposure; myopia; time outdoor; validation; wearable light tracker; PUBLIC-POLICIES; EXPOSURE; MYOPIA; TIME;
D O I
10.1111/opo.13061
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose We developed a clip-on light tracker (MyLyt) for estimating light exposure in real time. This study aimed at validating and investigating the feasibility of using MyLyt in children and adults. Method The study was conducted in two phases. Phase 1 involved validation against a factory-calibrated digital lux meter in three separate conditions: controlled environmental set-up, outdoors and indoors where intra-test (two measurements by the same tracker), inter-test (measurements among trackers) and inter-device (MyLyt tracker and lux meter) validations were conducted. Phase 2 involved a feasibility study where MyLyt was used in a real-world setting by 21 adults and 8 children. Participants were asked to log their real-time movements in an 'activity diary', which were correlated with the lux levels measured by the tracker. Results A strong positive correlation and non-significant difference in the recorded mean illuminance levels were observed during intra-test (inter-class correlation: 1.00, p = 0.99), inter-test (0.91-1.00, p > 0.15) and inter-device (0.91-1.00, p > 0.56) validation in all three testing conditions (p > 0.49), except the indoor location. While the lux level measured by MyLyt was significantly higher than that of the lux meter (p < 0.01) in the indoor locations, differences were minimal and clinically insignificant. A Bland-Altman plot showed a minimal mean difference (95% limits of agreement) between the MyLyt tracker and lux meter in all three conditions (controlled environmental set-up: 641 [-949, 2230], outdoor: 74 [-2772, 2920] and indoor: -35 [-151, 80] lux). Phase 2 validation showed an expected illuminance level against the corresponding location with high sensitivity (97.8%) and specificity (99%) to accurately differentiate between outdoor and indoor locations. Conclusion The MyLyt tracker showed good repeatability, strong correlation and comparable values with the lux meter in the three tested conditions, making it suitable for tracking light exposure patterns for both research and clinical purposes.
引用
收藏
页码:132 / 140
页数:9
相关论文
共 50 条
  • [41] SYSTEM VALIDATION STUDY FOR NOVEL WEARABLE SLEEP APNEA SCREENING DEVICE
    Makinen, N.
    Huuskonen, U.
    Hannila, E.
    Pisila, A. -P.
    Alaniemi, L.
    Koskinen, K.
    Tenhunen, M.
    Starck, T.
    Himanen, S. -L.
    Kallio, M.
    Sabil, A.
    Penzel, T.
    [J]. SLEEP MEDICINE, 2022, 100 : S279 - S279
  • [43] Development of A Wearable Exercise Device for Rehabilitation of Hemiplegic Hand
    Serbest, Kasim
    Ylidiz, Mustafa Zahid
    Cilli, Murat
    Karayel, Durmus
    Tekeoglu, Ibrahim
    Eldogan, Osman
    [J]. 2016 20TH NATIONAL BIOMEDICAL ENGINEERING MEETING (BIYOMUT), 2016,
  • [44] Development of a Wearable Pulse Transit Time Monitoring Device
    Jung, Dong-Keun
    Ha, Jeong-Seo
    Kang, Ku-Tae
    Kim, Kwang-Nyon
    Kim, Ki-Ryon
    Ye, Soo-Young
    Ro, Jung-Hoon
    Jeon, Gye-Rok
    [J]. HEALTHCARE INFORMATICS RESEARCH, 2008, 14 (03) : 295 - 302
  • [45] Development of the Wearable Device to Measure a Floor Reacting Force
    Fukunaga, Michihiko
    Ichinose, Hayato
    Ishizaka, Shogo
    [J]. 2018 11TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2018), 2018,
  • [46] Towards the development of a wearable rehabilitation device for stroke survivors
    Henrey, Michael
    Sheridan, Cormac
    Khokhar, Zeeshan Omer
    Menon, Carlo
    [J]. IEEE TIC-STH 09: 2009 IEEE TORONTO INTERNATIONAL CONFERENCE: SCIENCE AND TECHNOLOGY FOR HUMANITY, 2009, : 12 - 17
  • [47] Development of a Wearable Device for Monitoring People with Heart Problems
    Enache, Cristina-Daniela
    Tudorache, Simona Gabriela
    Ulmeanu, Coriolan Emil
    Voiculescu, Daniel Iulian
    Becheanu, Cristina-Adriana
    Florea, Andreea Daniela
    [J]. 2020 INTERNATIONAL CONFERENCE ON E-HEALTH AND BIOENGINEERING (EHB), 2020,
  • [48] Design and Development of a Wearable Device for Heat Stroke Detection
    Chen, Sheng-Tao
    Lin, Shih-Sung
    Lan, Chien-Wu
    Hsu, Hao-Yen
    [J]. SENSORS, 2018, 18 (01):
  • [49] Development of Wearable Pulsed Magnetic Field Generation Device
    Zhao, Chuncheng
    Wang, Pingping
    Si, Donglin
    Wang, Ming
    [J]. PROCEEDINGS OF 2023 INTERNATIONAL CONFERENCE ON WIRELESS POWER TRANSFER, VOL 3, ICWPT 2023, 2024, 1160 : 205 - 212
  • [50] The need for the development of a wearable home respiratory assist device
    Nose, Y
    [J]. ARTIFICIAL ORGANS, 1996, 20 (08) : 821 - 821