Validation of inertial measurement units for the assessment of trunk control in subjects with spinal cord injury

被引:3
|
作者
Isaac Perez-Sanpablo, Alberto [1 ,2 ]
Quinzanos-Fresnedo, Jimena [3 ]
Romero-Ixtla, Marco [4 ]
Valeria Aguirre-Guemez, Ana [5 ]
Rodriguez-Reyes, Gerardo [6 ]
Perez-Zavala, Ramiro [5 ]
Barrera-Ortiz, Aida [5 ]
Quijano-Gonzalez, Yannick [1 ,2 ]
机构
[1] Natl Inst Rehabil Luis Guillermo Ibarra Ibarra, Human Mot Anal Lab, Res Div, Mexico City, DF, Mexico
[2] Natl Inst Rehabil Luis Guillermo Ibarra Ibarra, Rehabil Engn Dept, Mexico City, DF, Mexico
[3] Natl Inst Rehabil Luis Guillermo Ibarra Ibarra, Neurol Rehabil Div, Mexico Xochimilco Av 289,Res Tower 6th Floor, Mexico City 14389, DF, Mexico
[4] Natl Inst Rehabil Luis Guillermo Ibarra Ibarra, Hlth Educ Direct, Mexico City, DF, Mexico
[5] Natl Inst Rehabil Luis Guillermo Ibarra Ibarra, Spinal Cord Injury Rehabil Serv, Neurol Rehabil Div, Mexico City, DF, Mexico
[6] Natl Inst Rehabil Luis Guillermo Ibarra Ibarra, Orthot & Prosthet Lab, Mexico City, DF, Mexico
来源
JOURNAL OF SPINAL CORD MEDICINE | 2023年 / 46卷 / 01期
关键词
Spinal cord injuries; Inertial measurement units; Trunk control; ASSESSMENT TOOLS; BALANCE; INDIVIDUALS; RELIABILITY; ACCELEROMETRY; STABILITY; VALIDITY; PEOPLE; INDEPENDENCE;
D O I
10.1080/10790268.2021.1975083
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Trunk control (TC) constitutes one of the main objectives in the rehabilitation of people with a spinal cord injury (SCI), but there are few clinically validated tests to assess it. Accelerometers have been proposed as sensitive and suitable procedures to assess TC. Objective : To evaluate test-retest reliability, construct and criterion validity of accelerometer parameters to assess TC in people with SCI. Methods A cross-sectional study of simultaneous application of Clinical Trunk Control Test (CTCT) and accelerometer evaluation was conducted. Accelerometers were placed on the trunks of 27 people with SCI and 15 people without SCI. Reliability was assessed by three repeated measures in random order of selected static and dynamic TC tasks. Acceleration on three axes was analyzed using five metrics. Criterion validity was assessed by analyzing correlation of acceleration to CTCT scores. Construct validity was assessed by analyzing capacity of inertial measurement units (IMU) to differentiate individual's characteristics, ASIA Impairment scale, gait capacity, level of TC, and neurological level of injury. Results Reliable IMU data were obtained in people with SCI and without SCI, of all accelerometer axes, metrics, and tested items of the CTCT. Reliability of acceleration decreases with the increasing demand for TC tasks. Ten acceleration parameters showed construct and criterion validity. Conclusion Accelerometer parameters are reliable, valid, and sensitive to evaluate TC in people with SCI. Significance A set of IMU parameters were validated as reliable and valid measures to evaluate TC, which could be useful for the assessment of progression of people with SCI and clinical interventions.
引用
收藏
页码:154 / 163
页数:10
相关论文
共 50 条
  • [21] Isokinetic assessment of spasticity in subjects with traumatic spinal cord injury (ASIA A)
    AC Franzoi
    C Castro
    C Cardone
    Spinal Cord, 1999, 37 : 416 - 420
  • [22] Assessment of walking speed and distance in subjects with an incomplete spinal cord injury
    van Hedel, Hubertus J. A.
    Dietz, Volker
    Curt, Armin
    NEUROREHABILITATION AND NEURAL REPAIR, 2007, 21 (04) : 295 - 301
  • [23] Isokinetic assessment of spasticity in subjects with traumatic spinal cord injury (ASIA A)
    Franzoi, AC
    Castro, C
    Cardone, C
    SPINAL CORD, 1999, 37 (06) : 416 - 420
  • [24] Improving walking assessment in subjects with an incomplete spinal cord injury: responsiveness
    van Hedel, H. J. A.
    Wirz, M.
    Curt, A.
    SPINAL CORD, 2006, 44 (06) : 352 - 356
  • [25] Measurement in spinal cord injury
    Edmond, P
    SPINAL CORD, 2004, 42 (04) : 209 - 210
  • [26] Measurement in spinal cord injury
    P Edmond
    Spinal Cord, 2004, 42 : 209 - 210
  • [27] An Inertial Measurement Unit-Based Wireless System for Shoulder Motion Assessment in Patients with Cervical Spinal Cord Injury: A Validation Pilot Study in a Clinical Setting
    Bravi, Riccardo
    Caputo, Stefano
    Jayousi, Sara
    Martinelli, Alessio
    Biotti, Lorenzo
    Nannini, Ilaria
    Cohen, Erez James
    Quarta, Eros
    Grasso, Stefano
    Lucchesi, Giacomo
    Righi, Gabriele
    Del Popolo, Giulio
    Mucchi, Lorenzo
    Minciacchi, Diego
    SENSORS, 2021, 21 (04) : 1 - 25
  • [28] Inertial measurement units furnish accurate trunk trajectory reconstruction of the sit-to-stand manoeuvre in healthy subjects
    Daniele Giansanti
    Giovanni Maccioni
    Francesco Benvenuti
    Velio Macellari
    Medical & Biological Engineering & Computing, 2007, 45 : 969 - 976
  • [29] Inertial measurement units furnish accurate trunk trajectory reconstruction of the sit-to-stand manoeuvre in healthy subjects
    Giansanti, Daniele
    Maccioni, Giovanni
    Benvenuti, Francesco
    Macellari, Velio
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (10) : 969 - 976
  • [30] A robot-based assessment of trunk control in Spinal Cord Injured athletes
    Marchesi, Giorgia
    Ricaldone, Elena
    Luca, Alice De
    Torre, Karin
    Quinland, Elisabetta
    Bellitto, Amy
    Squeri, Valentina
    Massone, Antonino
    Casadio, Maura
    Canessa, Andrea
    2020 8TH IEEE RAS/EMBS INTERNATIONAL CONFERENCE FOR BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2020, : 497 - 502