Langmuir-Blodgett Films with Immobilized Glucose Oxidase Enzyme Molecules for Acoustic Glucose Sensor Application

被引:6
|
作者
Gorbachev, Ilya [1 ]
Smirnov, Andrey [1 ]
Ivanov, George R. R. [2 ]
Venelinov, Tony [2 ]
Amova, Anna [2 ]
Datsuk, Elizaveta [1 ]
Anisimkin, Vladimir [1 ]
Kuznetsova, Iren [1 ]
Kolesov, Vladimir [1 ]
机构
[1] Kotelnikov Inst Radio Engn & Elect RAS, Moscow 125009, Russia
[2] Univ Architecture Civil Engn & Geodesy, Univ Lab Nanosci & Nanotechnol, Sofia 1164, Bulgaria
基金
俄罗斯科学基金会; 美国国家科学基金会;
关键词
Langmuir-Blodgett films; Langmuir monolayers; enzymatic biosensors; acoustoelectronic glucose sensor; LIPID MONOLAYERS; ADSORPTION; BIOSENSOR;
D O I
10.3390/s23115290
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a sensitive coating based on Langmuir-Blodgett (LB) films containing monolayers of 1,2-dipalmitoyl-sn-glycero-3-phosphoethanolamine (DPPE) with an immobilized glucose oxidase (GOx) enzyme was created. The immobilization of the enzyme in the LB film occurred during the formation of the monolayer. The effect of the immobilization of GOx enzyme molecules on the surface properties of a Langmuir DPPE monolayer was investigated. The sensory properties of the resulting LB DPPE film with an immobilized GOx enzyme in a glucose solution of various concentrations were studied. It has shown that the immobilization of GOx enzyme molecules into the LB DPPE film leads to a rising LB film conductivity with an increasing glucose concentration. Such an effect made it possible to conclude that acoustic methods can be used to determine the concentration of glucose molecules in an aqueous solution. It was found that for an aqueous glucose solution in the concentration range from 0 to 0.8 mg/mL the phase response of the acoustic mode at a frequency of 42.7 MHz has a linear form, and its maximum change is 55 degrees. The maximum change in the insertion loss for this mode was 18 dB for a glucose concentration in the working solution of 0.4 mg/mL. The range of glucose concentrations measured using this method, from 0 to 0.9 mg/mL, corresponds to the corresponding range in the blood. The possibility of changing the conductivity range of a glucose solution depending on the concentration of the GOx enzyme in the LB film will make it possible to develop glucose sensors for higher concentrations. Such technological sensors would be in demand in the food and pharmaceutical industries. The developed technology can become the basis for creating a new generation of acoustoelectronic biosensors in the case of using other enzymatic reactions.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] From Langmuir-Blodgett films to single molecules
    Orrit, Michel
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 74 (02) : 396 - 400
  • [22] Langmuir-Blodgett films containing cluster molecules
    Obydenov, AY
    Gubin, SP
    Khanin, VV
    Polyakov, SN
    Sergeev-Cherenkov, AN
    Soldatov, ES
    Trifonov, AS
    Khomutov, GB
    BIOLOGICHESKIE MEMBRANY, 2001, 18 (04): : 328 - 336
  • [23] Application of polyaniline-Langmuir-Blodgett films as a glucose biosensor
    Ramanathan, K
    Ram, MK
    Malhotra, BD
    Murthy, ASN
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 1995, 3 (3-4): : 159 - 163
  • [24] GLUCOSE SENSOR BASED ON DERIVATIZED POLYPYRROLE LANGMUIR-BLODGETT-FILMS
    SKOTHEIM, TA
    HALE, PD
    LEE, HS
    KARAN, HI
    OKAMOTO, Y
    SAMUELSON, L
    TRIPATHY, S
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 168 - PMSE
  • [25] ELABORATION OF A GLUCOSE BIOSENSOR BASED ON LANGMUIR-BLODGETT TECHNOLOGY
    FIOL, C
    VALLETON, JM
    DELPIRE, N
    BARBEY, G
    BARRAUD, A
    RUAUDELTEIXIER, A
    THIN SOLID FILMS, 1992, 210 (1-2) : 489 - 491
  • [26] Preparation of glucose sensors using the Langmuir-Blodgett technique
    Yasuzawa, M
    Hashimoto, M
    Fujii, S
    Kunugi, A
    Nakaya, T
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 65 (1-3) : 241 - 243
  • [27] Spectroscopic properties of retinoid molecules in Langmuir-Blodgett films
    Kimura, N
    Matuo, T
    Machida, K
    Imai, K
    Sawada, T
    Tsubono, I
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS SCIENCE AND TECHNOLOGY SECTION A-MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 1999, 337 : 353 - 356
  • [28] New molecules for supramolecular architecture in Langmuir-Blodgett films
    Isz, S
    Martinez, MV
    Palacin, S
    Perez, H
    RuaudelTeixier, A
    ORGANIC COATINGS, 1996, (354): : 394 - 410
  • [29] Characterization of IgG Langmuir-Blodgett films immobilized on functionalized polymers
    Preininger, C
    Clausen-Schaumann, H
    Ahluwalia, A
    de Rossi, D
    TALANTA, 2000, 52 (05) : 921 - 930
  • [30] GLUCOSE SENSOR - RAPID RESPONSE AND STABLE ENZYME SENSOR FOR GLUCOSE WITH AN ASYMMETRIC ULTRAFILTRATION MEMBRANE AND IMMOBILIZED GLUCOSE-OXIDASE
    KOYAMA, M
    KOEZUKA, J
    SATO, Y
    TOSHIBA REVIEW, 1981, (132): : 28 - 32