Novel conformable stent-graft repair of abdominal aortic aneurysms with hostile neck anatomy: A single-centre experience

被引:4
|
作者
Lee, Seong Hoon [1 ]
Melvin, Ross [1 ]
Kerr, Stacey [1 ]
Barakova, Lucie [2 ]
Wilson, Alasdair [1 ]
Renwick, Bryce [1 ]
机构
[1] NHS Grampian, Dept Vasc Surg, Aberdeen Royal Infirm, Aberdeen, Scotland
[2] Univ Aberdeen, Sch Med, Inst Appl Hlth Sci, Aberdeen, Scotland
关键词
Abdominal aortic aneurysms; endovascular procedures; endovascular aneurysm repair; hostile neck; vascular surgical procedure; OUTCOMES; AAA;
D O I
10.1177/17085381221124990
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives Abdominal aortic aneurysms (AAAs) demonstrating hostile neck anatomy (HNA) are associated with increased perioperative risk and mortality. A number of these patients are not suitable for standard endovascular aneurysm repair (EVAR) and are high risk for open surgery. We present our experience with the first implantations in Scotland of a novel conformable aortic stent-graft designed to overcome some of the challenges of HNAs. Methods From May 2018 to March 2022, 24 consecutive patients with non-ruptured AAAs demonstrating HNAs (neck length < 15 mm, or angulation > 60 degrees) were treated with GORE Excluder Conformable AAA endoprosthesis (CLEVAR) (CEXC Device, W.L. Gore and Associates, Flagstaff, AZ, USA) at a Scottish vascular centre. We assessed clinical outcomes and technical success of CLEVAR during deployment, primary admission and the post-operative period at 3- and 12-month clinical follow-up alongside CT angiography. Results Twenty-four patients (20 males, mean age 75.6) were included. Primary technical success of proximal seal zones and CLEVAR deployment (no type 1/3 endoleaks, no conversion to open repair, AAA excluded and patient leaving theatre alive) was achieved in 100% of patients. All patients were alive and clinically stable at 3- and 12-month follow-up. There were five patients requiring re-intervention; at the 3-month follow-up, one patient (4.2%) developed a type 1b endoleak requiring graft limb extension, one patient developed a right common femoral artery dissection requiring open repair and one patient required a limb extension of the right iliac limb due to risk of developing a type 1b endoleak. At the 12-month follow-up, two patients required embolization of type 2 endoleaks and no patients demonstrated type 1 or type 3 endoleaks. Conclusions: In-hospital and post-operative 3- and 12-month clinical and angiographic outcomes demonstrate safety and efficacy with CLEVARs in treating unruptured AAAs with HNA. Further research involving larger heterogenous sample sizes is warranted to determine long-term clinical outcomes.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 50 条
  • [21] Endovascular stent-graft repair of ruptured aortic aneurysms
    Scharrer-Pamler, R
    Kotsis, T
    Kapfer, X
    Görich, J
    Sunder-Plassmann, L
    JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (03) : 447 - 452
  • [22] Endovascular repair of abdominal aortic aneurysms in patients with severe angulation of the proximal neck using a flexible stent-graft: European Multicenter Experience
    Albertini, J. N.
    Perdikides, T.
    Soong, C. V.
    Hinchliffe, R. J.
    Trojanowksa, M.
    Yusuf, S. W.
    Clement, C.
    Hopkinson, B. R.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2006, 47 (03): : 245 - 250
  • [23] Device Conformability and Morphological Assessment After TEVAR for Aortic Type B Dissection: A Single-Centre Experience with a Conformable Thoracic Stent-Graft Design
    Bischoff, Moritz S.
    Mueller-Eschner, Matthias
    Meisenbacher, Katrin
    Peters, Andreas S.
    Boeckler, Dittmar
    MEDICAL SCIENCE MONITOR BASIC RESEARCH, 2015, 21 : 262 - 270
  • [24] Endovascular stent-graft repair of large abdominal aortic aneurysms in high risk patients
    Chuter, TA
    Gordon, RL
    LaBerge, JM
    Ring, EJ
    Kerlan, RK
    Reilly, LM
    RADIOLOGY, 1997, 205 : 78 - 78
  • [25] Endovascular repair of abdominal aortic aneurysms: Stent-graft fixation across the visceral arteries
    Burks, JA
    Faries, PL
    Gravereaux, EC
    Hollier, LH
    Marin, ML
    JOURNAL OF VASCULAR SURGERY, 2002, 35 (01) : 109 - 113
  • [26] Change in aneurysm diameter after stent-graft repair of ruptured abdominal aortic aneurysms
    Arya, N
    Lee, B
    Loan, W
    Johnston, LC
    Boyd, CS
    Hannon, RJ
    Soong, CV
    JOURNAL OF ENDOVASCULAR THERAPY, 2004, 11 (03) : 319 - 322
  • [27] Endovascular repair of ruptured abdominal aortic aneurysms with the endurant stent-graft: a combined experience from three centers
    Papazoglou, Konstantinos
    Mallios, Alexandros
    Buster, Bryan
    Antoniadis, Pavlos
    Karkos, Christos
    Staramos, Dimitris
    Dervisis, Konstantinos
    Messiner, Ryan
    Blebea, John
    JOURNAL OF CARDIOVASCULAR SURGERY, 2017, 58 (05): : 643 - 649
  • [28] Anaconda aortic stent-graft: Single-center experience of a new commercially available device for abdominal aortic aneurysms
    Saratzis, Nikolaos
    Melas, Nikolaos
    Saratzis, Athanasios
    Lazarides, John
    Ktenidis, Kyriakos
    Tsakiliotis, Sotirios
    Kiskinis, Dimitrios
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (01) : 33 - 41
  • [29] Midterm follow-up of a single-center experience of endovascular repair of abdominal aortic aneurysms with use of the talent stent-graft
    Seriki, Dare Mutiyu
    Ashleigh, Raymond J.
    Butterfield, J. S.
    England, Andrew
    McCollum, Charles N.
    Akhtar, Nasirn
    Welch, Colin
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (06) : 973 - 977
  • [30] Endovascular Treatment of Ruptured Abdominal Aortic Aneurysms with Hostile Aortic Neck Anatomy
    Broos, P. P. H. L.
    't Mannetje, Y. W.
    Cuypers, Ph. W. M.
    van Sambeek, M. R. H. M.
    Teijink, J. A. W.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 50 (03) : 313 - 319