Investigations of the effects of a passive bumper on the seismic response of base-isolated buildings: Experimental study and parameter optimization

被引:3
|
作者
Zhong, Weijian [1 ,2 ]
Liu, Yanhui [2 ]
Mercan, Oya [3 ]
Zhou, Fulin [2 ]
机构
[1] Xian Univ Architecture & Technol XAUAT, Dept Civil Engn, Xian, Peoples R China
[2] Guangzhou Univ, Earthquake Engn Res & Test Ctr EERTC, Wai Huan Xi Rd 230, Guangzhou 510006, Peoples R China
[3] Univ Toronto, Dept Civil & Mineral Engn, Toronto, ON, Canada
关键词
base isolation; shock-absorbers; passive bumper; compression tests; NSGA-II; parameter optimization; MITIGATION;
D O I
10.1177/10775463221086351
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The horizontal displacement values experienced by the isolation layer of base-isolated buildings can exceed the allowable range and cause failures during the rare or very-rare earthquakes. Excessive horizontal displacements of the isolation layer may cause collisions between the building and retaining walls of the isolation ditch and even cause the collapse of the isolated building. This paper proposes a cost-effective, easy-to-build, passive bumper device, called Flexible Limit Protective Device (FLPD) in order to act as shock-absorbers. Through numerical simulations and experiments, the nonlinear behavior of the FLPD is investigated. Subsequently, through structural simulations, the effectiveness of using FLPDs is studied. The elitist non-dominated sorting genetic algorithm (NSGA-II) is used to optimize the design of FLPDs, and the response of structures equipped with optimized FLPDs are simulated numerically. The results indicate that proposed optimized FLPDs can effectively work as shock-absorbers for base-isolated structures. This paper can provide a guideline for the design of shock-absorbers.
引用
下载
收藏
页码:2842 / 2853
页数:12
相关论文
共 50 条
  • [41] Investigation of atypical seismic response of a base-isolated bridge
    Chaudhary, MTA
    Abé, M
    Fujino, Y
    ENGINEERING STRUCTURES, 2002, 24 (07) : 945 - 953
  • [42] Seismic response of base-isolated liquid storage tanks
    Shrimali, MK
    Jangid, RS
    JOURNAL OF VIBRATION AND CONTROL, 2003, 9 (10) : 1201 - 1218
  • [43] Non-stationary seismic response analysis of base-isolated buildings with many hysteretic devices
    Ma, C. F.
    Zhang, Y. H.
    Tan, P.
    Kennedy, D.
    Williams, F. W.
    Zhou, F. L.
    COMPUTERS & STRUCTURES, 2013, 123 : 39 - 47
  • [44] Seismic response of multi-storey buildings base-isolated by friction devices with restoring properties
    Caliò, I
    Marletta, M
    Vinciprova, F
    COMPUTERS & STRUCTURES, 2003, 81 (28-29) : 2589 - 2599
  • [45] Seismic response of sliding equipment and contents in base-isolated buildings subjected to broadband ground motions
    Konstantinidis, Dimitrios
    Nikfar, Farzad
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2015, 44 (06): : 865 - 887
  • [46] Seismic Response of Base-Isolated High-Rise Buildings under Fully Nonstationary Excitation
    Ma, C. F.
    Zhang, Y. H.
    Tan, P.
    Zhou, F. L.
    SHOCK AND VIBRATION, 2014, 2014
  • [47] SEISMIC BEHAVIOR OF BASE-ISOLATED BUILDINGS - A STATE-OF-THE-ART REVIEW
    JANGID, RS
    DATTA, TK
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 1995, 110 (02) : 186 - 203
  • [48] Effects of Spatial Variable Ground Motions on the Seismic Response of Base-Isolated Building
    Lei, Yongqin
    Du, Yongfeng
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 4422 - 4428
  • [49] Experimental Assessment of the Seismic Response of a Base-Isolated Building Through a Hybrid Simulation Technique
    Furinghetti, Marco
    Lanese, Igor
    Pavese, Alberto
    FRONTIERS IN BUILT ENVIRONMENT, 2020, 6
  • [50] Analysis of base-isolated buildings considering vertical seismic responses and P-delta effects
    Zhao, YM
    Ma, DH
    Guo, XD
    Su, JY
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON EARTHQUAKE ENGINEERING: NEW FRONTIER AND RESEARCH TRANSFORMATION, 2004, : 745 - 749