A Soft-Tissue Landmark to Assess Humeral Component Rotation in Total Elbow Arthroplasty

被引:0
|
作者
Azimi, Hassan [1 ]
Ahmad, Farhan [1 ]
Sabet, Andre D. [1 ]
Cohen, Mark [1 ]
Maschke, Steve [2 ]
Wysocki, Robert [1 ]
Simcock, Xavier [1 ]
机构
[1] Rush Univ, Dept Orthoped Surg, Med Ctr, Chicago, IL 60612 USA
[2] Cleveland Clin Fdn, Dept Orthoped Surg, Cleveland Hts, OH USA
关键词
elbow; total elbow arthroplasty; intermuscular septum; flexion-extension axis; landmark; humeral rotation; ALIGNMENT; AXIS; WEAR;
D O I
10.7759/cureus.41729
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Hypothesis: Assessing the rotational alignment of the humeral component during total elbow arthroplasty is dependent upon bony landmarks that can be absent or altered in cases of distal humerus fractures, revision arthroplasty, severe bone loss, or deformity. We hypothesize that the intermuscular septum can be used as a reliable soft-tissue landmark to set the rotation of the humeral component intra-operatively when previously described bony landmarks are not reliable or present.Materials and methods: Forty-eight unpaired cadaveric human subjects (mean age and standard deviation 63 & PLUSMN; 12 years; 24 males, 24 females) underwent computed tomography (CT) scans. The geometric centers of the trochlea and capitellum were assessed, and the line through these two points was set as the flexion -extension axis (FEA) of the elbow. The intermuscular septum axis (IMSA) was drawn proximal to the olecranon fossa and at least 4 cm proximal to the most distal point of the articular surface, where the posterior humeral cortex was flat. The angles between the FEA and IMSA were calculated and compared using a two-tailed t-test. Regression analysis was used to assess the inter-and intra-observer reliability of the IMSA.Results: The IMSA was externally rotated 10.3 & DEG; & PLUSMN; 2.8 compared to the FEA (p < 0.001 and confidence interval (CI) of 2.8 with & alpha; set to 0.01). The inter-and intra-observer reliability of the IMSA was high, with an R-value of 0.91 and 0.97, respectively.Conclusions: The intermuscular septum can be used as a soft-tissue landmark to set humeral component rotation and is 10.3 & DEG; externally rotated with respect to the FEA of the ulnohumeral joint.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] PAIN AFTER TOTAL KNEE ARTHROPLASTY CAUSED BY SOFT-TISSUE IMPINGEMENT
    HIRSH, DM
    SALLIS, JG
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (04): : 591 - 592
  • [32] Soft-Tissue Balance in Short and Straight Stem Total Hip Arthroplasty
    Windhagen, Henning
    Chincisan, Andra
    Choi, Hon Fai
    Thorey, Fritz
    ORTHOPEDICS, 2015, 38 (03) : S14 - S20
  • [33] Soft-tissue Balancing During Total Knee Arthroplasty in the Varus Knee
    Mihalko, William M.
    Saleh, Khaled J.
    Krackow, Kenneth A.
    Whiteside, Leo A.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (12) : 766 - 774
  • [34] Soft-tissue balancing with pressure distribution during total knee arthroplasty
    Takahashi, T
    Wada, Y
    Yamamoto, H
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (02): : 235 - 239
  • [35] Soft-tissue Defects After Total Knee Arthroplasty: Management and Reconstruction
    Osei, Daniel A.
    Rebehn, Kelsey A.
    Boyer, Martin I.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2016, 24 (11) : 769 - 779
  • [36] Secondary total elbow arthroplasty after distal humeral fracture
    Ries, Christian
    Wegmann, Kilian
    Hackl, Michael
    Burkhart, Klaus Josef
    Mueller, Lars Peter
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2014, 9 (03): : 156 - 162
  • [37] The role of total elbow arthroplasty in complex distal humeral fractures
    Patton, Michael S.
    Johnstone, Alan J.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2008, 34 (02) : 99 - 104
  • [38] The Role of Total Elbow Arthroplasty in Complex Distal Humeral Fractures
    Michael S. Patton
    Alan J. Johnstone
    European Journal of Trauma and Emergency Surgery, 2008, 34 : 99 - 104
  • [39] IMAGE-BASED NAVIGATION IMPROVES THE ACCURACY AND REPRODUCIBILITY OF HUMERAL COMPONENT POSITIONING IN TOTAL ELBOW ARTHROPLASTY
    McDonald, Colin P.
    Johnson, James A.
    Peters, Terry M.
    King, Graham J. W.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 243 - 244
  • [40] Component fracture after total elbow arthroplasty
    Lee, Homin
    Vaichinger, Anthony M.
    O'Driscoll, Shawn W.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (08) : 1449 - 1456