One-year safety and effectiveness of the Agent paclitaxel-coated balloon for the treatment of small vessel disease and in-stent restenosis

被引:3
|
作者
Nakamura, Masato [1 ]
Isawa, Tsuyoshi [2 ]
Nakamura, Shigeru [3 ]
Ando, Kenji [4 ]
Namiki, Atsuo [5 ]
Shibata, Yoshisato [6 ]
Shinke, Toshiro [7 ]
Ito, Yoshiaki [8 ]
Fujii, Kenshi [9 ]
Shite, Junya [10 ]
Kozuma, Ken [11 ]
Saito, Shigeru [12 ]
Yamaguchi, Junichi [13 ]
Yamazaki, Seiji [14 ]
Underwood, Paul [15 ]
Allocco, Dominic J. [15 ]
机构
[1] Toho Univ, Div Minimally Invas Treatment Cardiovasc Med, Div Cardiovasc Med, Ohashi Med Ctr, 2-22-36,Ohashi Meguro Ku, Tokyo 1538515, Japan
[2] Sendai Kousei Hosp, Dept Cardiol, Sendai, Miyagi, Japan
[3] Kyoto Katsura Hosp, Cardiovasc Ctr, Kyoto, Japan
[4] Kokura Mem Hosp, Dept Cardiol, Fukuoka, Japan
[5] Kanto Rosai Hosp, Dept Neurol, Kawasaki, Kanagawa, Japan
[6] Miyazaki Med Assoc Hosp, Dept Cardiol, Miyazaki, Japan
[7] Showa Univ Hosp, Dept Cardiol, Tokyo, Japan
[8] Saiseikai Yokohama City Eastern Hosp, Dept Cardiol, Yokohama, Kanagawa, Japan
[9] Sakurabashi Watanabe Hosp, Dept Cardiol, Osaka, Japan
[10] Osaka Saiseikai Nakatsu Hosp, Dept Cardiol, Osaka, Japan
[11] Teikyo Univ Hosp, Dept Cardiol, Tokyo, Japan
[12] Shonan Kamakura Gen Hosp, Heart Ctr, Kawasaki, Kanagawa, Japan
[13] Tokyo Womens Med Univ Hosp, Dept Cardiol, Tokyo, Japan
[14] Sapporo Higashi Tokushukai Hosp, Dept Cardiol, Sapporo, Hokkaido, Japan
[15] Boston Sci Corp, Intervent Cardiol, Marlborough, MA USA
关键词
Small vessel disease; In-stent restenosis; Drug-coated balloon; DRUG-ELUTING BALLOON; PERCUTANEOUS CORONARY INTERVENTION; RANDOMIZED MULTICENTER; ARTERY-DISEASE; ANGIOPLASTY; LESIONS; TRIALS;
D O I
10.1007/s12928-023-00953-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Agent device consists of a semi-compliant balloon catheter, which is coated with a therapeutic low-dose formulation of paclitaxel (2 mu g/mm(2)) blended with an inactive excipient acetyl-tri-n-butyl citrate (ATBC). AGENT Japan SV is a randomized controlled study that enrolled 150 patients from 14 Japanese sites treated with Agent or SeQuent Please paclitaxel-coated balloon. This study also includes a single-arm substudy evaluating the safety and effectiveness of Agent in patients with in-stent restenosis (ISR). Patients with a single de novo native lesion (lesion length <= 28 mm and reference diameter >= 2.00 to < 3.00 mm) were randomized 2:1 to receive either Agent (n = 101) or SeQuent Please (n = 49). The ISR substudy enrolled 30 patients with lesion length <= 28 mm and reference diameter >= 2.00 to <= 4.00 mm. In the SV RCT, target lesion failure (TLF) at 1 year occurred in four patients treated with Agent (4.0%) versus one patient with SeQuent Please (2.0%; P = 1.00). None of the patients in either treatment arm died. There were no significant differences in the rates of myocardial infarction, target lesion revascularization and target lesion thrombosis through 1 year. In the ISR substudy, the 1-year rates of TLF and target lesion thrombosis were 6.7% and 0.0%, respectively. These data support the safety and effectiveness of the Agent paclitaxel-coated balloon in patients with small vessels and ISR.
引用
收藏
页码:47 / 56
页数:10
相关论文
共 50 条
  • [41] LONG-TERM CLINICAL RESULTS OF SEQUENT PLEASE PACLITAXEL-COATED BALLOON ANGIOPLASTY FOR THE TREATMENT OF IN-STENT RESTENOSIS
    Benezet, J.
    Sanchez-Perez, I.
    Lozano, F.
    Higuera, F.
    Pinilla, N.
    Hessein, Y.
    Arizon, J. M.
    CARDIOLOGY, 2013, 126 : 64 - 64
  • [42] Long-Term Clinical Results Of SeQuent Please Paclitaxel-Coated Balloon Angioplasty For The Treatment Of In-Stent Restenosis
    Benezet, Javier
    Sanchez-Perez, Ignacio
    Lozano, Fernando
    Higuera, Felipe
    Pinilla, Natalia
    Hessein, Yasser
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B138 - B138
  • [43] Safety and efficacy of paclitaxel drug-coated balloon in femoropopliteal in-stent restenosis
    Anantha-Narayanan, Mahesh
    Love, Keith
    Nagpal, Sameer
    Sheikh, Azfar Bilal
    Regan, Christopher J.
    Mena-Hurtado, Carlos
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (06) : 533 - 539
  • [44] Long-Term Clinical Results of SeQuent Please® Paclitaxel-Coated Balloon Angioplasty for the Treatment of In-Stent Restenosis
    Benezet, J.
    Sanchez-Perez, I
    Lozano, F.
    Higuera, F.
    Pinilla, N.
    Hessein, Y.
    Arizon, J. M.
    CORONARY ARTERY DISEASE 2013, 2013, : 303 - 305
  • [45] Paclitaxel-coated Drug Eluting Balloon Less Effective for Treatment of in-stent Restenosis in Drug Eluting Stent as Compared to Bare Metal Stent
    Ostheim, Patrick
    Resch, Markus
    CIRCULATION, 2013, 128 (22)
  • [46] Sex-Specific Clinical Outcomes After Treatment of In-Stent Restenosis With the AGENT Paclitaxel-Coated Balloon: A Subgroup Analysis of the AGENT IDE Randomized Trial
    Tremmel, Jennifer
    McEntegart, Margaret
    Shlofmitz, Richard
    Kirtane, Ajay
    Bachinsky, William
    Dohad, Suhail
    Rudick, Steven
    Stoler, Robert
    Jefferson, Brian
    Nicholson, William
    Altman, John
    Bateman, Cinthia
    Krishnaswamy, Amar
    Ang, Lawrence
    Levisay, Justin
    Abbott, J. Dawn
    Kearney, Kate
    Jaffer, Farouc
    Bhatt, Pooja
    Song, Shannon
    Yeh, Robert
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B164 - B165
  • [47] Comparison of the efficacy of balloon angioplasty or paclitaxel-coated balloon or stent implantation for in-stent restenosis based on analysis by optical coherence tomography
    Yamane, K.
    Hayashi, Y.
    Fujii, Y.
    Ueda, Y.
    Morita, Y.
    Miyake, Y.
    Fujiwara, M.
    Nagamoto, Y.
    Mito, S.
    Watari, Y.
    Tamekiyo, H.
    Okimoto, T.
    Muraoka, Y.
    EUROPEAN HEART JOURNAL, 2018, 39 : 528 - 528
  • [48] Treatment of restenosis with a paclitaxel-coated balloon catheter - Reply
    Camenzind, Edoardo
    NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (10): : 1072 - 1073
  • [49] Long-Term Follow-Up After Treatment of Coronary In-Stent Restenosis With a Paclitaxel-Coated Balloon Catheter
    Scheller, Bruno
    Clever, Yvonne P.
    Kelsch, Bettina
    Hehrlein, Christoph
    Bocksch, Wolfgang
    Rutsch, Wolfgang
    Haghi, Dariush
    Dietz, Ulrich
    Speck, Ulrich
    Boehm, Michael
    Cremers, Bodo
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (03) : 323 - 330
  • [50] PREDICTORS OF RECURRENT RESTENOSIS AFTER TREATMENT OF DRUG-ELUTING STENT RESTENOSIS WITH PACLITAXEL-COATED BALLOON
    Habara, Seiji
    Kadota, Kazushige
    Kanazawa, Takenori
    Ichinohe, Tahei
    Kubo, Shunsuke
    Miyake, Koshi
    Hyodo, Yusuke
    Hasegawa, Daiji
    Tada, Takeshi
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    Mitsudo, Kazuaki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1886 - A1886