Synthesis of molecularly imprinted polymer as a nanosorbent for dispersive magnetic micro solid-phase extraction and determination of valsartan in biological samples by UV-Vis Spectrophotometry: Isotherm, kinetics, and thermodynamic studies

被引:10
|
作者
Azizi-Khereshki, Nasibeh [1 ,2 ]
Mousavi, Hassan Zavvar [1 ]
Dogaheh, Mahtab Ghasemi [2 ]
Farsadrooh, Majid [3 ]
Alizadeh, Nina [1 ]
Mohammadi, Asadollah [1 ]
机构
[1] Univ Guilan, Fac Sci, Dept Chem, Rasht, Iran
[2] Guilan Univ Med Sci, Sch Pharm, Dept Med Chem, Rasht, Iran
[3] Univ Sistan & Baluchestan, Fac Sci, Dept Chem, Renewable Energies Res Lab, POB 98135-674, Zahedan, Iran
关键词
Dispersive magnetic micro solid phase extraction; Molecularly imprinted polymer; UV-Vis spectrophotometry; Valsartan; LIQUID-CHROMATOGRAPHIC ANALYSIS; MODIFIED-BETA-CYCLODEXTRIN; II-RECEPTOR ANTAGONISTS; HUMAN PLASMA; FUNCTIONAL MONOMER; ACTIVATED CARBON; METHYLENE-BLUE; STIR BAR; HYDROCHLOROTHIAZIDE; VALIDATION;
D O I
10.1016/j.saa.2023.122656
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A magnetic molecularly imprinted polymer (MIP) was synthesized by precipitation polymerization utilizing Fe3O4@SiO2-MPS as a magnetic core, itaconic acid as a functional monomer, azobisisobutyronitrile as an initiator, and ethylene glycol dimethacrylate as a cross linker. It was then applied as a nanosorbent for dispersive magnetic micro solid phase extraction (DM-& mu;-SPE) and determination of valsartan in biological fluids. The morphology and structure of magnetic MIP were characterized by Fourier-transform infrared spectroscopy, Field Emission Scanning electron microscopy, Vibrating sample magnetometer, Energy dispersive x-ray analysis, and Thermogravimetric analysis. The influence of operation conditions on sorption, such as pH (4-10), contact time (10-25 min), initial concentration (1-30 mg L-1), and temperature (25-40 degrees C) was investigated. After the extraction step, the valsartan concentration was determined by UV-Vis spectrophotometer at 253 nm. The isotherm and kinetic of valsartan sorption were best fitted by the Langmuir model (R2 = 0.987) and the Pseudo second-order kinetic model (R2 = 0.971), respectively. The maximum monolayer sorption capacity for magnetic MIP was obtained to be 4.56 mg g-1. The analytical approach demonstrated favorable figures of merit, with a linear dynamic range of 10-100 & mu;g L-1, a low detection limit of 0.56 & mu;g L-1, and an acceptable preconcentration factor of 5 acquired in optimum conditions. The recoveries of the suggested technique at three spiked levels of analysis were in the range of 101 %-102 %. Valsartan was extracted from various real samples (urine and human blood plasma samples) utilizing the proposed magnetic nanosorbent, and the results exhibited that magnetic MIP was favorable for extraction and measurement of trace amounts of valsartan in biological samples.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Synthesis of magnetic molecular imprinted polymer with a new functional monomer for dispersive micro solid phase extraction of captopril from wastewater and biological samples and determination by UV-Vis spectrophotometry
    Sabbaghi, Najmeh
    Shabani, Ali Mohammad Haji
    Dadfarnia, Shayessteh
    Farsadrooh, Majid
    MICROCHIMICA ACTA, 2023, 190 (04)
  • [2] Synthesis of magnetic molecular imprinted polymer with a new functional monomer for dispersive micro solid phase extraction of captopril from wastewater and biological samples and determination by UV-Vis spectrophotometry
    Najmeh Sabbaghi
    Ali Mohammad Haji Shabani
    Shayessteh Dadfarnia
    Majid Farsadrooh
    Microchimica Acta, 2023, 190
  • [3] Molecularly imprinted polymer-based dispersive solid-phase extraction for the selective determination of carisoprodol in biological and pharmaceutical samples
    Manhas, Sakshi
    Bajaj, Atul
    Jain, Bharti
    Kumar, Deepak
    Singh, Jaskaran
    Shukla, Saurabh
    Jain, Rajeev
    NEW JOURNAL OF CHEMISTRY, 2023, 47 (30) : 14436 - 14446
  • [4] Magnetic molecularly imprinted polymer nanoparticles for dispersive micro solid-phase extraction and determination of buprenorphine in human urine samples by HPLC-FL
    Habibi, Biuck
    Rostamkhani, Shiva
    Hamidi, Mehrdad
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2018, 15 (07) : 1569 - 1580
  • [5] Magnetic molecularly imprinted polymer nanoparticles for dispersive micro solid-phase extraction and determination of buprenorphine in human urine samples by HPLC-FL
    Biuck Habibi
    Shiva Rostamkhani
    Mehrdad Hamidi
    Journal of the Iranian Chemical Society, 2018, 15 : 1569 - 1580
  • [6] Rapid determination of metanil yellow in turmeric using a molecularly imprinted polymer dispersive solid-phase extraction and visible light spectrophotometry
    Arabkhani, Sahar
    Pourmoslemi, Shabnam
    Harchegani, Amir Larki
    FOOD CHEMISTRY, 2022, 380
  • [7] Dispersive micro-solid-phase extraction using chitosan/polymethacrylate/clay bionanocomposite followed by UV-Vis spectrophotometry for determination of zinc
    Uygun, H. Deniz E.
    Antep, Mine
    Demir, M. Nalan
    Merdivan, Melek
    CHEMICAL PAPERS, 2020, 74 (10): : 3399 - 3408
  • [8] Dummy molecularly imprinted magnetic nanoparticles for dispersive solid-phase extraction and determination of bisphenol A in water samples and orange juice
    Wu, Xiao
    Li, Yarong
    Zhu, Xiaoliang
    He, Chiyang
    Wang, Qiang
    Liu, Shaorong
    TALANTA, 2017, 162 : 57 - 64
  • [9] Molecularly imprinted magnetic nanoparticles for the micro solid-phase extraction of thiabendazole from citrus samples
    Garcia-Fernandez, Miguel
    Diaz-Alvarez, Myriam
    Martin-Esteban, Antonio
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (12) : 2638 - 2644
  • [10] Molecularly imprinted dispersive micro solid-phase extraction and tandem derivatization for the determination of histamine in fermented wines
    Fang-Yi Liao
    Jing-Ru Weng
    Ying-Chi Lin
    Chia-Hsien Feng
    Analytical and Bioanalytical Chemistry, 2024, 416 : 945 - 957