Synthesis of magnetic molecular imprinted polymer with a new functional monomer for dispersive micro solid phase extraction of captopril from wastewater and biological samples and determination by UV-Vis spectrophotometry

被引:8
|
作者
Sabbaghi, Najmeh [1 ]
Shabani, Ali Mohammad Haji [1 ]
Dadfarnia, Shayessteh [1 ]
Farsadrooh, Majid [2 ]
机构
[1] Yazd Univ, Fac Sci, Dept Chem, Yazd 89195741, Iran
[2] Univ Sistan & Baluchestan, Fac Sci, Dept Chem, Renewable Energies Res Lab, POB 98135 674, Zahedan, Iran
关键词
Captopril; Dispersive magnetic micro solid phase extraction; Magnetic molecularly imprinted polymer; N-(allylcarbamothioyl)-2-chlorobenzamide; UV-Vis spectrophotometry; PERFORMANCE LIQUID-CHROMATOGRAPHY; HUMAN PLASMA; INJECTION-ANALYSIS; DRUG; MICROEXTRACTION; SEPARATION;
D O I
10.1007/s00604-023-05746-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A magnetic molecularly imprinted polymer (MMIP) was fabricated for captopril by surface polymerization of Fe3O4@SiO2 nanoparticles using a new functional monomer of N-( allylcarbamothioyl)-2-chlorobenzamide. It was then employed as a selective nanosorbent for dispersive magnetic micro solid phase extraction ( DM-mu-SPE) of captopril from biological and wastewater samples. To characterize the physicochemical properties of the MMIP, different analytical methods such as the vibrating sample magnetometer, field emission scanning electron microscopy, Brunauer-Emmett-Teller, and Fourier transform infrared spectroscopy were utilized. To gain the maximum extraction recovery of captopril, the influence of various operating conditions was investigated and experimental settings optimized. After the extraction step, the concentration of captopril was measured by UV-Vis spectrophotometer at 245 nm. The assessments demonstrated that the MMIP provides higher extraction efficiency in comparison to magnetic non-imprinted polymer, suggesting the establishment of selective recognition binding sites at the MMIP surface. The method depicted desirable figures of merit of a low detection limit of 0.16 mu g L-1, a limit of quantification of 0.50 mu g L-1, a linear dynamic range of 0.50-22.0 mu g L-1, and an acceptable preconcentration factor of 333. The magnetic MIP was successfully employed for preconcentration and extraction of trace amounts of captopril in real samples, such as human blood serum, urine, and wastewater samples, with recoveries in the range 95.7 to 102.6% and relative standard deviations < 5%.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Synthesis of magnetic molecular imprinted polymer with a new functional monomer for dispersive micro solid phase extraction of captopril from wastewater and biological samples and determination by UV-Vis spectrophotometry
    Najmeh Sabbaghi
    Ali Mohammad Haji Shabani
    Shayessteh Dadfarnia
    Majid Farsadrooh
    [J]. Microchimica Acta, 2023, 190
  • [2] Synthesis of molecularly imprinted polymer as a nanosorbent for dispersive magnetic micro solid-phase extraction and determination of valsartan in biological samples by UV-Vis Spectrophotometry: Isotherm, kinetics, and thermodynamic studies
    Azizi-Khereshki, Nasibeh
    Mousavi, Hassan Zavvar
    Dogaheh, Mahtab Ghasemi
    Farsadrooh, Majid
    Alizadeh, Nina
    Mohammadi, Asadollah
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 296
  • [3] Double-imprinted polymer based on cross-linked poly(vinylimidazole-trimethylolpropane trimethacrylate) in solid phase extraction for determination of lead from wastewater samples by UV-vis spectrophotometry
    da Santos Silva, Ricky Cassio
    Pires, Bruna Carneiro
    Borges, Keyller Bastos
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2019, 99 (10) : 949 - 967
  • [4] Dispersive micro-solid-phase extraction using chitosan/polymethacrylate/clay bionanocomposite followed by UV-Vis spectrophotometry for determination of zinc
    Uygun, H. Deniz E.
    Antep, Mine
    Demir, M. Nalan
    Merdivan, Melek
    [J]. CHEMICAL PAPERS, 2020, 74 (10): : 3399 - 3408
  • [5] Dispersive micro-solid-phase extraction using chitosan/polymethacrylate/clay bionanocomposite followed by UV–Vis spectrophotometry for determination of zinc
    H. Deniz E. Uygun
    Mine Antep
    M. Nalan Demir
    Melek Merdivan
    [J]. Chemical Papers, 2020, 74 : 3399 - 3408
  • [6] Green and efficient magnetic micro-solid phase extraction utilizing tea waste impregnated with magnetic nanoparticles for the analysis of ibuprofen in water samples by using UV-vis spectrophotometry
    Muniandy, Yagulan
    Mohamad, Sharifah
    Raoov, Muggundha
    [J]. RSC ADVANCES, 2024, 14 (17) : 11977 - 11985
  • [7] Magnetic molecularly imprinted polymer nanoparticles for dispersive micro solid-phase extraction and determination of buprenorphine in human urine samples by HPLC-FL
    Habibi, Biuck
    Rostamkhani, Shiva
    Hamidi, Mehrdad
    [J]. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2018, 15 (07) : 1569 - 1580
  • [8] Magnetic molecularly imprinted polymer nanoparticles for dispersive micro solid-phase extraction and determination of buprenorphine in human urine samples by HPLC-FL
    Biuck Habibi
    Shiva Rostamkhani
    Mehrdad Hamidi
    [J]. Journal of the Iranian Chemical Society, 2018, 15 : 1569 - 1580
  • [9] Molecularly imprinted polymer-based dispersive solid-phase extraction for the selective determination of carisoprodol in biological and pharmaceutical samples
    Manhas, Sakshi
    Bajaj, Atul
    Jain, Bharti
    Kumar, Deepak
    Singh, Jaskaran
    Shukla, Saurabh
    Jain, Rajeev
    [J]. NEW JOURNAL OF CHEMISTRY, 2023, 47 (30) : 14436 - 14446
  • [10] Application of molecularly imprinted polymer pipette tip micro-solid phase extraction of nalidixic acid and acetaminophen from pills and seawater samples and their determination by spectrophotometry
    Sayyed Hossein Hashemi
    Massoud Kaykhaii
    Ahmad Jamali Keikha
    Nasrin Naruie
    [J]. Chemical Papers, 2020, 74 : 4009 - 4023