Changes in the corrected carotid flow time can predict spinal anesthesia-induced hypotension in patients undergoing cesarean delivery: an observational study

被引:5
|
作者
Juri, Takashi [1 ]
Suehiro, Koichi [1 ]
Yasuda, Shinta [1 ]
Kimura, Aya [1 ]
Fujimoto, Yohei [1 ]
Mori, Takashi [1 ]
机构
[1] Osaka Metropolitan Univ, Grad Sch Med, Dept Anesthesiol, 1-5-7 Asahimachi,Abenoku, Osaka 5458586, Japan
关键词
Cesarean delivery; Hypotension; Corrected flow time; PLETH VARIABILITY INDEX; HEART-RATE-VARIABILITY; FLUID RESPONSIVENESS; RESPIROPHASIC VARIATION; SECTION; ARTERY; ULTRASONOGRAPHY; PRESSURE; ABILITY; VOLUME;
D O I
10.1007/s00540-023-03293-2
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose Spinal anesthesia is a standard technique for cesarean delivery; however, it possesses a risk of hypotension. We hypothesised that the changes in the corrected flow time induced by the Trendelenburg position could predict the incidence of hypotension after spinal anesthesia for cesarean delivery.Methods Patients undergoing elective cesarean delivery under spinal anesthesia were enrolled. Before anesthesia induction, corrected flow time was measured in the supine and Trendelenburg positions (FTc-1 and FTc-2, respectively). Additionally, a percent change in corrected flow time induced by the Trendelenburg position was defined as Delta FTc. The primary endpoint was to investigate the ability of Delta FTc to predict the incidence of spinal anesthesia-induced hypotension until delivery. The receiver operating characteristics curves to assess the ability of FTc-1, FTc-2, and Delta FTc to predict the incidence of hypotension were generated.Results Finally, 40 patients were included, and of those, 26 (65%) developed spinal anesthesia-induced hypotension. The areas under the curve for FTc-1, FTc-2, and Delta FTc were 0.591 (95% CI: 0.424 to 0.743) (P = 0.380), 0.742 (95% CI: 0.579 to 0.867) (P = 0.004), and 0.882 (95% CI: 0.740 to 0.962) (P < 0.001) respectively, indicating Delta FTc as the best predictor among these three parameters. The best threshold for Delta FTc was 6.4% (sensitivity: 80.8% (95% CI: 53.8 to 96.2), specificity: 85.7% (95% CI: 42.9 to 100.0)).Conclusions This study demonstrated that changes in the corrected carotid flow time induced by the Trendelenburg position could serve as a good predictor of spinal anesthesia-induced hypotension for cesarean delivery.
引用
收藏
页码:105 / 113
页数:9
相关论文
共 50 条
  • [1] Changes in the corrected carotid flow time can predict spinal anesthesia-induced hypotension in patients undergoing cesarean delivery: an observational study
    Takashi Juri
    Koichi Suehiro
    Shinta Yasuda
    Aya Kimura
    Yohei Fujimoto
    Takashi Mori
    [J]. Journal of Anesthesia, 2024, 38 : 105 - 113
  • [2] Pleth variability index measured in the sitting position before anesthesia can predict spinal anesthesia-induced hypotension in cesarean section: An observational study
    Ozyurt, Erhan
    [J]. JOURNAL OF OBSTETRIC ANAESTHESIA AND CRITICAL CARE, 2022, 12 (01) : 47 - 52
  • [3] Ultrasonographic Carotid Artery Flow Measurements as Predictors of Spinal Anesthesia-Induced Hypotension in Elderly Patients: A Prospective Observational Study
    Kim, Hyae-Jin
    Cho, Ah-Reum
    Lee, Hanbit
    Kim, Haekyu
    Kwon, Jae -Young
    Kang, Christine
    Be, Soeun Jeon
    Kim, Nara
    [J]. MEDICAL SCIENCE MONITOR, 2022, 28
  • [4] Use of vasopressors to manage spinal anesthesia-induced hypotension during cesarean delivery
    Park, Hee-Sun
    Choi, Woo-Jong
    [J]. ANESTHESIA AND PAIN MEDICINE, 2024, 19 (02):
  • [5] Spinal anesthesia-induced hypotension: A risk comparison between patients with severe preeclampsia and healthy women undergoing preterm cesarean delivery
    Aya, AGM
    Vialles, N
    Tanoubi, I
    Mangin, R
    Ferrer, JM
    Robert, C
    Ripart, J
    de La Coussaye, JE
    [J]. ANESTHESIA AND ANALGESIA, 2005, 101 (03): : 869 - 875
  • [6] Changes in corrected carotid flow time induced by recruitment maneuver predict fluid responsiveness in patients undergoing general anesthesia
    Aya Kimura
    Koichi Suehiro
    Takashi Juri
    Katsuaki Tanaka
    Takashi Mori
    [J]. Journal of Clinical Monitoring and Computing, 2022, 36 : 1069 - 1077
  • [7] Changes in corrected carotid flow time induced by recruitment maneuver predict fluid responsiveness in patients undergoing general anesthesia
    Kimura, Aya
    Suehiro, Koichi
    Juri, Takashi
    Tanaka, Katsuaki
    Mori, Takashi
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (04) : 1069 - 1077
  • [8] Can subclavian/infraclavicular axillary vein collapsibility index predict spinal anesthesia-induced hypotension in cesarean-section operations?
    Aslanlar, E.
    Sargin, M.
    Aslanlar, D. A.
    Onal, O.
    [J]. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (21) : 10411 - 10418
  • [9] Exploring the predictive value of combined ultrasound parameters for spinal anesthesia-induced hypotension in cesarean section: a prospective observational study
    Shimiao Feng
    Juan Gu
    Chao Yu
    Jin Liu
    Juan Ni
    [J]. BMC Anesthesiology, 23
  • [10] Exploring the predictive value of combined ultrasound parameters for spinal anesthesia-induced hypotension in cesarean section: a prospective observational study
    Feng, Shimiao
    Gu, Juan
    Yu, Chao
    Liu, Jin
    Ni, Juan
    [J]. BMC ANESTHESIOLOGY, 2023, 23 (01)