Outcomes of chlorhexidine lavage without capsulectomy versus complete capsulectomy after lead extraction for the treatment of cardiac implantable electronic device infection

被引:1
|
作者
Diaz, Juan Carlos [1 ]
Marin, Jorge E. [2 ]
Aristizabal, Julian M. [2 ]
Bastidas, Oriana [1 ]
Hoyos, Carolina [3 ]
Matos, Carlos [3 ]
Lopez-Cabanillas, Nestor [4 ]
Matias, Jose [5 ]
Di Biase, Luigi [5 ]
Romero, Jorge [3 ,6 ]
机构
[1] Clin Las Vegas, Cardiac Arrhythmia & Electrophysiol Serv, Medellin, Colombia
[2] Clin Las Americas, Cardiac Arrhythmia & Electrophysiol Serv, Medellin, Colombia
[3] Harvard Med Sch, Brigham & Womens Hosp, Cardiac Arrhythmia Serv, Cardiovasc Div, Boston, MA 02115 USA
[4] Adventist Cardiovasc Inst, Buenos Aires, Argentina
[5] Albert Einstein Coll Med, Cardiac Arrhythmia Ctr, Montefiore Med Ctr, Div Cardiol, New York, NY USA
[6] Harvard Med Sch, Brigham & Womens Hosp, Cardiac Arrhythmia Serv, 75 Francis St, Boston, MA 02115 USA
关键词
capsulectomy; chlorhexidine; CIED; device-related infection; pacemaker; GENERATOR REPLACEMENT; IRRIGATION; PREVENTION; MANAGEMENT; IMPACT; TRIAL;
D O I
10.1111/jce.15856
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionCapsulectomy is recommended in patients with cardiac implantable electronic device (CIED) infection after transvenous lead extraction (TLE) but is time-consuming and requires extensive tissue debridement. In this study, we describe the outcomes of chlorhexidine gluconate (CHG) lavage in lieu of capsulectomy for the treatment of CIED infections. MethodsThis retrospective study included patients who underwent TLE for CIED-related infections in two institutions in Colombia. In the capsulectomy group, complete capsulectomy was performed after hardware removal. In the CHG group, exhaustive lavage of the generator pocket with 20 cc of CHG at 2% followed by irrigation with approximately 500 cc of normal saline (0.9% sodium chloride) was performed. The primary outcomes included reinfection and hematoma formation in the generator pocket. Secondary outcomes included the occurrence of any adverse reaction to chlorhexidine, the need for reintervention, infection-related mortality, and total procedural time. ResultsA total of 102 patients (mean age 67.2 +/- 13 years, 32.4% female) underwent CIED extraction with either total capsulectomy (n = 54) or CHG (n = 48) lavage. Hematoma formation was significantly higher in the capsulectomy group versus the CHG group (13% vs. 0%, p = .014), with no significant differences in the reinfection rate. Capsulectomy was associated with longer procedural time (133.7 +/- 78.5 vs. 89.9 +/- 51.8 min, p = .002). No adverse reactions to CHG were found. Four patients (4.3%) died from worsening sepsis: three in the capsulectomy group and one in the CHG group (p = .346). ConclusionsIn patients with CIED infections, the use of CHG without capsulectomy resulted in a lower risk of hematoma formation and shorter procedural times without an increased risk of reinfection or adverse events associated with CHG use.
引用
收藏
页码:1024 / 1032
页数:9
相关论文
共 50 条
  • [41] Transvenous lead extraction versus surgical lead extraction or conservative treatment for cardiac implantable electronic device infections: Propensity score-weighted analyses of a nationwide claim-based database
    Wada, Mitsuru
    Inoue, Yuko Y.
    Nakai, Michikazu
    Sumita, Yoko
    Tonegawa-Kuji, Reina
    Miyazaki, Yuichiro
    Wakamiya, Akinori
    Shimamoto, Keiko
    Ueda, Nobuhiko
    Nakajima, Kenzaburo
    Kamakura, Tsukasa
    Yamagata, Kenichiro
    Ishibashi, Kohei
    Miyamoto, Koji
    Nagase, Satoshi
    Aiba, Takeshi
    Iwanaga, Yoshitaka
    Miyamoto, Yoshihiro
    Kusano, Kengo
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2023, 46 (08): : 833 - 839
  • [42] Impact of Immunosuppressive Therapy on Lead Dislodgement After Cardiac Implantable Electronic Device Implantation
    Matsuda, Yasuhiro
    Masuda, Masaharu
    Asai, Mitsutoshi
    Okamoto, Shin
    Ishihara, Takayuki
    Nanto, Kiyonori
    Tsujimura, Takuya
    Hata, Yosuke
    Uematsu, Hiroyuki
    Higashino, Naoko
    Nakao, Sho
    Kusuda, Masaya
    Mano, Toshiaki
    CLINICAL CARDIOLOGY, 2024, 47 (06)
  • [43] Lead Extraction for Cardiovascular Implantable Electronic Device Infection in Patients With Left Ventricular Assist Devices
    Black-Maier, Eric
    Piccini, Jonathan P.
    Bishawi, Muath
    Pokorney, Sean D.
    Bryner, Benjamin
    Schroder, Jacob N.
    Fowler, Vance G., Jr.
    Katz, Jason N.
    Haney, John C.
    Milano, Carmelo A.
    Nicoara, Alina
    Hegland, Donald D.
    Daubert, James P.
    Lewis, Robert K.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (06) : 672 - 680
  • [44] Outcomes After Cardiac Implantable Electronic Devices Among People With and Without HIV
    Xiao, Sophia Y.
    Thakkar, Anjali
    Ma, Yifei
    Durstenfeld, Matthew S.
    Hsue, Priscilla Y.
    CIRCULATION, 2023, 148
  • [45] Outcomes of complete removal versus conservative therapy in cardiac implantable electronic device infections - A systematic review and Meta-analysis
    Caldonazo, Tulio
    Fischer, Johannes
    Spagnolo, Alena
    Dell'Aquila, Michele
    Kirov, Hristo
    Tasoudis, Panagiotis
    Treml, Ricardo E.
    Vervoort, Dominique
    Sa, Michel Pompeu
    Doenst, Torsten
    Diab, Mahmoud
    Hagel, Stefan
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2024, 411
  • [46] One-year Impact of Clinical and Echocardiographic Parameters in Cardiac Implantable Electronic Device Infection after Transvenous Extraction
    Weisz, Sara Hana
    Sordelli, Chiara
    Fele, Nunzia
    Guarino, Angela
    Verde, Raffaele
    Zucchelli, Giulio
    Severino, Corrado
    Attanasio, Vittorio
    De Vivo, Stefano
    Tascini, Carlo
    Severino, Sergio
    JOURNAL OF CARDIOVASCULAR ECHOGRAPHY, 2024, 34 (04) : 196 - 202
  • [47] Trends and outcomes of inpatient cardiac implantable electronic device transvenous lead extractions: a nationwide analysis
    Khalil, Charl
    Lazar, Sorin
    Megaly, Michael
    Mekritthikrai, Raktham
    Vipparthy, Sharath C.
    Doukky, Rami
    Mortada, Mohammad E.
    Huang, Henry D.
    Sharma, Parikshit S.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024,
  • [48] Impact of Infective versus Sterile Transvenous Lead Removal on Outcomes in Cardiac Implantable Electronic Devices
    Talaei, Fahimeh
    Ang, Qi-Xuan
    Hassan, Mustafa
    Lee, Justin Zon-ern
    Tamirisa, Kamala
    CIRCULATION, 2023, 148
  • [49] Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark
    Kirkfeldt, Rikke Esberg
    Johansen, Jens Brock
    Nohr, Ellen Aagaard
    Jorgensen, Ole Dan
    Nielsen, Jens Cosedis
    EUROPEAN HEART JOURNAL, 2014, 35 (18) : 1186 - 1194
  • [50] Leadless cardiac pacing after lead extraction in patients with severe device infection
    Blessberger, H.
    Kypta, A.
    Kammler, J.
    Hrncic, D.
    Schwarz, S.
    Lambert, T.
    Nahler, A.
    Hoenig, S.
    Saleh, K.
    Kiblboeck, D.
    Kellermair, J.
    Lichtenauer, M.
    Steinwender, C.
    WIENER KLINISCHE WOCHENSCHRIFT, 2016, 128 : S294 - S295