Mutual Influence of External Wall Thermal Transmittance, Thermal Inertia, and Room Orientation on Office Thermal Comfort and Energy Demand

被引:0
|
作者
Bozicek, David [1 ]
Kunic, Roman [1 ]
Krainer, Ales [2 ]
Stritih, Uros [3 ]
Dovjak, Mateja [1 ]
机构
[1] Univ Ljubljana, Fac Civil & Geodet Engn, Jamova Cesta 2, Ljubljana 1000, Slovenia
[2] Inst Publ & Environm Hlth, Ljubljana 1000, Slovenia
[3] Univ Ljubljana, Fac Mech Engn, Askrceva Cesta 6, Ljubljana 1000, Slovenia
关键词
office building; thermal comfort; energy demand; thermal inertia; orientation; INDOOR ENVIRONMENT QUALITY; PERFORMANCE; BUILDINGS; MASS; EFFICIENCY; ENVELOPE; DESIGN; IEQ; AIR;
D O I
10.3390/en16083524
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Upgrades in building energy efficiency codes led to differences between buildings designed according to outdated codes and those with most recent requirements. In this context, our study investigates the influence of external wall thermal transmittance, thermal inertia, and orientation on energy demand (heating, cooling) and occupant thermal comfort. Simulation models of an office building were designed, varying (i) the thermal transmittance values (0.20 and 0.60 W/(m(2)K)), (ii) the room orientation (four cardinal directions), and (iii) the wall thermal inertia (approximately 60 kJ/(m(2)K) for low and 340 kJ/(m(2)K) for high thermal inertia. The energy demand for heating and cooling seasons was calculated for Ljubljana using EnergyPlus 9.0.0 software. The reduction of the external wall thermal transmittance value from 0.6 W/(m(2)K) to 0.2 W/(m(2)K) contributes to significant energy savings (63% for heating and 37% for cooling). Thermal inertia showed considerable potential for energy savings, especially in the cooling season (20% and 13%, depending on the external wall insulation level). In addition, the orientation proved to have a notable impact on heating and cooling demand, however not as pronounced as thermal inertia (up to 7% total energy demand). Comparison of the thermal comfort results showed that when internal air temperatures are identically controlled in all the rooms (i.e., internal air temperature is not an influencing factor), the external wall thermal transmittance, thermal inertia, and room orientation show negligible influence on the average occupant thermal comfort. The simultaneous achievement of thermally comfortable conditions in the working environment and low energy use can only be achieved by simultaneously considering the U-value and thermal inertia.
引用
收藏
页数:29
相关论文
共 50 条
  • [11] Modelling and experimenting thermal energy storage through the use of PCM in low thermal inertia office
    de Abreu, Duarte Drumond
    Costa Neto, Rui
    Aelenei, Laura
    Santos Silva, Carlos A.
    [J]. 2019 5TH INTERNATIONAL CONFERENCE ON POWER GENERATION SYSTEMS AND RENEWABLE ENERGY TECHNOLOGIES (PGSRET-2019), 2019, : 192 - 199
  • [12] Application of phase change materials, thermal insulation, and external shading for thermal comfort improvement and cooling energy demand reduction in an office building under different coastal tropical climates
    Nematchoua, Modeste Kameni
    Noelson, Jean Christophe Vanona
    Saadi, Ismail
    Kenfack, Herves
    Andrianaharinjaka, Aro-Zo F. R.
    Ngoumdoum, Dominique Foumouo
    Sela, Jao Barahimo
    Reiter, Sigrid
    [J]. SOLAR ENERGY, 2020, 207 : 458 - 470
  • [13] Energy use and thermal comfort in a rammed earth office building
    Taylor, P.
    Fuller, R. J.
    Luther, M. B.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (05) : 793 - 800
  • [14] Exploring the influence of qualitative factors on the thermal comfort of office occupants
    Healey, Kathryn
    Webster-Mannison, Marci
    [J]. ARCHITECTURAL SCIENCE REVIEW, 2012, 55 (03) : 169 - 175
  • [15] Thermal Inertia: Towards An Energy Conservation Room Management System
    Pan, Dawei
    Yuan, Yi
    Wang, Dan
    Xu, Xiaohua
    Peng, Yu
    Peng, Xiyuan
    Wan, Peng-Jun
    [J]. 2012 PROCEEDINGS IEEE INFOCOM, 2012, : 2606 - 2610
  • [16] A field study of thermal inertia of roofs and its influence on indoor comfort
    D'Orazio, Marco
    Di Perna, Costanzo
    Di Giuseppe, Elisa
    [J]. JOURNAL OF BUILDING PHYSICS, 2014, 38 (01) : 50 - 65
  • [17] Flow patterns and thermal comfort in a room with panel, floor and wall heating
    Myhren, Jonn Are
    Holmberg, Sture
    [J]. ENERGY AND BUILDINGS, 2008, 40 (04) : 524 - 536
  • [18] The Effect of Demand Response on Perceived Thermal Comfort in a District Heated Office Building
    Salo, Sonja
    Jokisalo, Juha
    Syri, Sanna
    Kosonen, Risto
    [J]. 2018 15TH INTERNATIONAL CONFERENCE ON THE EUROPEAN ENERGY MARKET (EEM), 2018,
  • [19] Measurements of thermal Transmittance of an External massive timber wall in-situ and in the Laboratory
    Geyer, Christoph
    Mueller, Andreas
    Wehle, Barbara
    [J]. 12TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB 2020), 2020, 172
  • [20] Energy savings and thermal comfort in a zero energy office building with fans in Singapore
    Kent, Michael G.
    Huynh, Nam Khoa
    Mishra, Asit Kumar
    Tartarini, Federico
    Lipczynska, Aleksandra
    Li, Jiayu
    Sultan, Zurami
    Goh, Edwin
    Karunagaran, Giridharan
    Natarajan, Arulmani
    Indrajith, Asiri
    Hendri, Ivanna
    Narendra, Komang I.
    Wu, Vicky
    Chin, Noel
    Gao, Chun Ping
    Sapar, Majid
    Seoh, Alvin
    Shuhadah, Nur
    Valliappan, Selvam
    Jukes, Tim
    Spanos, Costas
    Schiavon, Stefano
    [J]. BUILDING AND ENVIRONMENT, 2023, 243