Hyperkalemia-Induced T Wave Oversensing in an Implantable Cardioverter Defibrillator

被引:0
|
作者
Gonzalez, Ariel [1 ]
Franqui, Hilton [1 ]
Lopez, Jose [1 ]
Banchs, Hector [1 ]
机构
[1] Univ Puerto Rico, Med, Med Sci Campus, San Juan, Argentina
关键词
t wave oversensing; cardiac electrophysiology; implantable cardioverter-defibrillator (icd); cardiac implantable devices; severe hyperkalemia;
D O I
10.7759/cureus.54135
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 66 -year -old female with end -stage renal disease and heart failure with reduced ejection fraction, status post implantable cardioverter defibrillator (ICD) presented to the emergency department with dizziness and fatigue. An electrocardiogram showed sinus rhythm, complete atrioventricular block, and ventricular paced rhythm at 30 beats per minute (bpm). Device interrogation revealed a programmed VVI mode with a lower rate limit of 40 bpm and evidence of T wave oversensing. Serologic studies were remarkable for hyperkalemia (7.9 mmol/dL). The device was initially reprogrammed to provide a higher pacing rate and symptomatic improvement. Both complete AV block and T wave oversensing resolved after correction of hyperkalemia. This case highlights the need for vigilant monitoring of electrolyte imbalances in ICD patients.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Implantable cardioverter-defibrillator shocks increase T-Wave Alternans
    Lampert, Rachel J.
    Soufer, Robert
    McPherson, Craig A.
    Batsford, William P.
    Tirado, Stephanie
    Earley, Christine
    Goldberg, Anna
    Shusterman, Vladimir
    CIRCULATION, 2006, 114 (18) : 475 - 475
  • [42] Detection of T-wave alternans using an implantable cardioverter-defibrillator
    Paz, Offir
    Zhou, Xiaohong
    Gillberg, Jeff
    Tseng, Hsiang-Jer
    Gang, Eli
    Swerdlow, Charles
    HEART RHYTHM, 2006, 3 (07) : 791 - 797
  • [43] Implantable cardioverter-defibrillator shocks increase T-wave alternans
    Lampert, Rachel
    Shusterman, Vladimir
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (09) : E25 - E25
  • [44] THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR - T-WAVE SENSING IN THE NEWEST GENERATION
    SINGER, I
    DEBORDE, R
    VELTRI, EP
    SIDDOWAY, LA
    LEVINE, JH
    GRIFFITH, LSC
    GUARNIERI, T
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11): : 1584 - 1591
  • [45] HYPERKALEMIA-INDUCED PSEUDOINFARCTION PATTERN
    KLEIN, LW
    MELLER, J
    MOUNT SINAI JOURNAL OF MEDICINE, 1983, 50 (05): : 428 - 431
  • [46] T-Wave Oversensing in Patients With Brugada Syndrome: True Bipolar Versus Integrated Bipolar Implantable Cardioverter Defibrillator Leads Multicenter Retrospective Study
    Rodriguez-Manero, Moises
    de Asmundis, Carlo
    Sacher, Frederic
    Arbelo, Elena
    Probst, Vincent
    Castro-Hevia, Jesus
    Maury, Philippe
    Rollin, Anne
    Lambiase, Pier
    Garcia-Bolao, Ignacio
    Chierchia, Gian-Battista
    Kusano, Kengo Fukushima
    Gourraud, Jean-Baptiste
    Schilling, Richard
    Kamakura, Tsukasa
    Luis Martinez-Sande, Jose
    Haissaguerre, Michel
    Ramon Gonzalez-Juanatey, Jose
    Brugada, Jose
    Brugada, Pedro
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (04): : 792 - 798
  • [47] Impact of electrocardiogram screening during drug challenge test for the prediction of T-wave oversensing by a subcutaneous implantable cardioverter defibrillator in patients with Brugada syndrome
    Tsukasa Kamakura
    Mitsuru Wada
    Kohei Ishibashi
    Yuko Y. Inoue
    Koji Miyamoto
    Hideo Okamura
    Satoshi Nagase
    Takashi Noda
    Takeshi Aiba
    Satoshi Yasuda
    Kengo Kusano
    Heart and Vessels, 2017, 32 : 1277 - 1283
  • [48] Impact of electrocardiogram screening during drug challenge test for the prediction of T-wave oversensing by a subcutaneous implantable cardioverter defibrillator in patients with Brugada syndrome
    Kamakura, Tsukasa
    Wada, Mitsuru
    Ishibashi, Kohei
    Inoue, Yuko Y.
    Miyamoto, Koji
    Okamura, Hideo
    Nagase, Satoshi
    Noda, Takashi
    Aiba, Takeshi
    Yasuda, Satoshi
    Kusano, Kengo
    HEART AND VESSELS, 2017, 32 (10) : 1277 - 1283
  • [49] Avoidance of inappropriate ventricular tachycardia detection due to T-wave oversensing in an implantable cardioverter-defibrillator: An application of the EGM Width Criterion.
    Duru, F
    Bauersfeld, URS
    Candinas, R
    HEARTWEB, 1999, 4 (12): : U3 - U9
  • [50] Implantable cardioverter defibrillator shocks induced by showering
    Spurrell, P.
    Patel, N.
    Sulke, N.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2008, 62 (03) : 505 - 507