Experience of percutaneous closure of small to large patent ductus arteriosus with Nit-Occlud® device in a tertiary referral hospital in Colombia

被引:0
|
作者
Galvis-Luna, Sandra R. [1 ]
Guzman-Serrano, Carlos A. [2 ]
Olave-Rueda, Isabella [2 ]
Mejia-Quinones, Valentina [1 ,2 ]
Gutierrez-Gil, Jaiber [3 ]
Mosquera-Alvarez, Walter [3 ]
机构
[1] Univ Icesi, Fac Ciencias Salud, Cali, Colombia
[2] Fdn Valle Lili, Ctr Invest Clin, Cali, Colombia
[3] Fdn Valle Lili, Dept Maternoinfantil, Serv Cardiol Pediat, Cali, Colombia
来源
ARCHIVOS DE CARDIOLOGIA DE MEXICO | 2024年 / 94卷 / 03期
关键词
Patent ductus arteriosus; Nit-Occlud (R) device; Endovascular closure; Interventional devices; OCCLUD PDA DEVICE; TRIAL;
D O I
10.24875/ACM.23000267
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The decision to close patent ductus arteriosus should always be individualized and taken together with the child's family once the risks and benefits of both choices have been exposed. Objective: This study aims to report the experience and outcomes in patients undergoing endovascular closure of small to medium-size PDA with a Nit-Occlud (R) device in a tertiary referral hospital in Colombia. Methods: Longitudinal descriptive study, which included all patients under 18 years of age who underwent percutaneous ductal closure with Nit-Occlud (R) device between January 1, 2011, and February 1, 2023. Patients with associated complex congenital heart disease requiring surgical management, pregnant patients, and patients with incomplete data regarding studied variables were excluded from the study. Results: Eighty-seven patients were documented, with a mean age, weight, and height at closure of 51 months, 14 kg, and 95.83 cm, respectively. About 70% of the patients (n = 61) were female, 76% were under 6-years-old and only one patient was over 15. The average size of the ductus at the pulmonary end was 2 mm. Four of the total number of patients did not achieve PDA closure during the procedure. Of the remaining 83, complete immediate closure was achieved in 81 patients. A device exchange for a larger device was required during the same procedure in one of the cases. Two patients presented residual shunt of 0.5 mm during follow-up, and one required a new procedure for device closure 10 months later. Only one device presented repeatedly embolization to the aorta, requiring surgical removal. As a technical difficulty, one device presented repeated passage into the aorta, so it was decided to remove it before releasing it to avoid complications, and given the complex anatomy of the ductus, surgical closure was indicated. Among the complications, one patient presented a hematoma of the subcutaneous tissue in the right thigh, which improved with medical management, and no deaths related to the procedure were registered. Conclusions: Using the Nit-Occlud (R) device to close small to moderate-sized ductus remains a safe and effective strategy with successful closure rates at 1-year follow-up irrespective of age, weight, height, or whether it involves a small or medium-sized duct. Despite our limitations, results concerning adverse effects are comparable to those observed in multicentric studies conducted in other regions.
引用
收藏
页码:263 / 268
页数:6
相关论文
共 50 条
  • [21] Transcatheter closure of very large patent ductus arteriosus with the modified patent ductus arteriosus closure device.
    Zhang, F.
    Ge, J.
    Zhou, D.
    Guan, L.
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (8B): : 50D - 50D
  • [22] PERCUTANEOUS CLOSURE OF PATENT DUCTUS ARTERIOSUS: SINGLE CENTER EXPERIENCE
    Ucar, Birsen
    Kosger, Pelin
    Kiztanir, Hikmet
    ARCHIVES OF DISEASE IN CHILDHOOD, 2019, 104 : A38 - A39
  • [23] Percutaneous patent ductus arteriosus closure: Twelve years of experience
    Sarmento, Joao Antunes
    Correia-Costa, Ana
    Goncalves, Edite
    Baptista, Maria Joao
    Silva, Joao Carlos
    Moreira, Jorge
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2021, 40 (08) : 561 - 568
  • [24] Percutaneous closure of large patent ductus arteriosus in adult patients
    Hernandez, F.
    Garcia-Tejada, J.
    Velazquez, M. T.
    Gomez, I.
    Bastante, T.
    Unzue, L.
    Gonzalez, A.
    De Riva, M.
    EUROPEAN HEART JOURNAL, 2009, 30 : 393 - 393
  • [25] A child with acquired Gerbode defect due to infective endocarditis: Successful percutaneous closure with Nit-occlud device (R)
    Eden Santos, P.
    Villanueva, N. G.
    Ballesteros, F.
    Matamala-Morillo, M. A.
    Zunzunegui, J. L.
    PROGRESS IN PEDIATRIC CARDIOLOGY, 2018, 49 : 77 - 80
  • [26] Patent ductus arteriosus in preterm newborns: A tertiary hospital experience
    Santos, Joana
    Soares, Paulo
    Ferreras, Cristina
    Flor-de-Lima, Filipa
    Guimaraes, Hercilia
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2022, 41 (02) : 109 - 118
  • [27] Initial experience with the novel patent foramen ovale occlusion device Nit-Occlud® in patients with stroke or transient ischemic attack
    Steinberg, Daniel H.
    Bertog, Stefan C.
    Momberger, Julia
    Franke, Jennifer
    Hofmann, Ilona
    Renkhoff, Kristina
    Joy, Sonya
    Vaskelyte, Laura
    Sievert, Horst
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (07) : 1262 - 1267
  • [28] Closure of patent ductus arteriosus with OcclutechTM device, experience in an andean country
    Rios-Mendez, Raul E.
    Arauz-Martinez, Maria E.
    Oliveros-Rivero, Jorge A.
    Crespo-Gutierrez, Yeiber J.
    Perez-Vite, Yesenia W.
    ARCHIVOS DE CARDIOLOGIA DE MEXICO, 2024, 94 (02): : 169 - 173
  • [29] Interventional closure of patent foramen ovale with Nit-occlud® device in prevention of recurrent neurologic events-Long-term results
    Araszkiewicz, Aleksander
    Slawek, Sylwia
    Trojnarska, Olga
    Lesiak, Maciej
    Grygier, Marek
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (01) : 159 - 164
  • [30] Patent ductus arteriosus rupture during percutaneous device closure: a case report
    Kim, Hyun Ho
    You, Jihye
    CARDIOLOGY IN THE YOUNG, 2025,