Diameter and depth of femoral vessels by duplex ultrasound

被引:0
|
作者
Zambetti, Benjamin R. [1 ]
Kankaria, Aman [1 ]
Fang, Francia [1 ]
Kim, Nahye [1 ]
Nagarsheth, Khanjan [1 ]
Sarkar, Rajabrata [1 ]
机构
[1] Univ Maryland, Dept Surg, Div Vasc Surg, 22 S Greene St,Tenth Floor, Baltimore, MD 21201 USA
来源
JOURNAL OF VASCULAR ACCESS | 2025年 / 26卷 / 01期
关键词
Femoral anatomy; duplex ultrasound; vascular access; ARTERY; SEX; AGE; COMPLICATIONS;
D O I
10.1177/11297298231200036
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: The anatomy of the femoral artery and vein plays an integral role in vascular access. Both technical feasibility and complication rates are associated with femoral vessel diameter and depth. The goal of this study is to establish normative values for common femoral artery (CFA) and vein (CFV) depth and diameter using a large, diverse patient population. Methods: A retrospective review of all patients undergoing lower extremity venous duplex imaging over a 1 year period were reviewed. Patients with inadequate imaging or with evidence of deep vein thrombosis were excluded. The index image of all studies was a non-compressed view of the common femoral vein at the saphenous-femoral junction. All measurements were taken from this still. Vessel diameters were measured from intima to intima. Depth was measured from skin to intima. BMI and BSA were calculated using standard formulas. Chi square was used for univariate analysis. Linear regression was used to establish correlation. Results: Over the 1 year period, 983 patients met criteria for inclusion. The majority were male (53%) with a mean age of 55. The patients were 47% white and 44% black. The majority had hypertension (53%). The mean BMI and BSA were 29 and 2, respectively. Mean CFA depth was 1.7 cm, while mean CFV depth was 1.8 cm. The mean CFA and CFV diameters were 0.9 and 1.1 cm, respectively. Amongst height, weight, BMI, and BSA, weight correlated best with CFA (R = 0.548) and CFV (R = 0.552) depth, while BSA correlated best for diameter for both CFA (R = 0.390) and CFV (R = 0.440). Conclusions: This study establishes mean diameters and depths for the common femoral artery and vein using a large, diverse patient group. BSA was most closely associated with vessel diameter, while weight was correlated with depth. This study provides normative diameter and depth values for the common femoral vasculature, which may assist in vascular access planning for providers.
引用
收藏
页码:162 / 167
页数:6
相关论文
共 50 条
  • [21] Ultrasound evaluation of the anatomy of the vessels in relation to the femoral nerve at the femoral crease (vol 33, pg 491, 2011)
    Muhly, W. Ty
    Orebaugh, Steven L.
    SURGICAL AND RADIOLOGIC ANATOMY, 2011, 33 (08) : 745 - 745
  • [22] True Diameter of Vessels
    Vonder, Marleen
    Willems, Tineke P.
    van Melle, Joost P.
    Elzenga, Nynke J.
    Ebels, Tjark
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (04) : 448 - 449
  • [23] ACCURACY AND REPRODUCIBILITY OF DUPLEX ULTRASOUND IMAGING IN A PHANTOM MODEL OF FEMORAL-ARTERY STENOSIS
    WHYMAN, MR
    HOSKINS, PR
    LENG, GC
    ALLAN, PL
    DONNAN, PT
    RUCKLEY, CV
    FOWKES, FGR
    JOURNAL OF VASCULAR SURGERY, 1993, 17 (03) : 524 - 530
  • [24] Duplex ultrasound assessment of femoral venous flow during laparoscopic and open gastric bypass
    N.T. Nguyen
    M. Cronan
    S. Braley
    R. Rivers
    B.M. Wolfe
    Surgical Endoscopy And Other Interventional Techniques, 2003, 17 : 285 - 290
  • [25] Comparison of color coded duplex sonography and intravascular ultrasound for the evaluation of femoral artery atenoses
    Rieber, J
    Tato, F
    Meissner, O
    Rieger, J
    Schiele, TM
    Hoffmann, U
    Klauss, V
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 263A - 263A
  • [26] Measuring diameters of great saphenous vein and common femoral vein using duplex ultrasound
    Mendoza, E.
    PHLEBOLOGIE, 2014, 43 (05) : 263 - 267
  • [27] Duplex ultrasound assessment of femoral venous flow during laparoscopic and open gastric bypass
    Nguyen, NT
    Cronan, M
    Braley, S
    Rivers, R
    Wolfe, BM
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2003, 17 (02): : 285 - 290
  • [28] Comparison of intravascular ultrasound and colour coded duplex sonography for the evaluation of femoral artery stenoses
    Rieber, J
    Tató, F
    Meissner, O
    Rieger, J
    König, A
    Hoffmann, U
    Siebert, U
    Klauss, V
    EUROPEAN HEART JOURNAL, 2003, 24 : 90 - 90
  • [29] CANNULATION OF FEMORAL VESSELS
    GILSTON, A
    BRITISH JOURNAL OF ANAESTHESIA, 1976, 48 (05) : 500 - 501
  • [30] DUPLEX SONOGRAPHY OF ABDOMINAL VESSELS
    MILDENBERGER, P
    LOTZ, R
    KREITNER, KF
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1987, 147 (04): : 437 - 441