The experimental analysis on the influence of different conditions in microchannel on critical heat flux and boiling starting point

被引:5
|
作者
Liu, Xinmin [1 ]
Hua, Junye [1 ]
Lan, Hai [1 ]
Li, Dong [1 ]
Sang, Keyi [1 ]
Liu, Huiyan [1 ]
Zhang, Jing [1 ]
机构
[1] Nanjing Normal Univ NNU, Sch Energy & Mech Engn, Engn Lab Energy Syst Proc Convers & Emiss Reduct T, Nanjing 210042, Peoples R China
关键词
SINGLE-PHASE; PERFORMANCE; SINKS; ENHANCEMENT; FC-72;
D O I
10.1007/s00231-023-03400-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to explore the mechanism of boiling heat transfer in microchannels and the appearance of CHF and ONB under different conditions, a visualized experimental research has been conducted on the flow and heat transfer characteristics in microchannels. Combined with the behaviour of bubbles, the occurrence of ONB and CHF in the microchannels with different shapes, different flow velocities and different inflow directions has been compared and analyzed. Results indicate that, after the heat flux exceeds 20 W/cm(2), the four microchannels all enter the nucleate boiling stage (ONB), with little difference in order. The appearance of ONB for the droplet pin fin is the earliest (q(e) = 41.51 W/cm(2)), with non-closed pin fin with flow direction B (q(e) = 56.65 W/cm(2)) as the latest. Accordingly, the channel with droplet fin (q(e) = 106.2 W/cm(2)) pin fins appear CHF first, and the non-closed droplet shape (flow direction A: q(e) = 141.6 W/cm(2); flow direction B: no CHF) is the latest. While for the same channel, with the increase of mass flow, the convective heat transfer coefficient becomes higher and ONB and CHF will be delayed. For the different layout, the more favorable flow arrangement (flow direction B) is helpful to delay ONB and CHF. A comprehensive factors & eta; is introduced to evaluate the boiling flow and heat transfer performance of the microchannels with different situations. At higher heat flux density (58 W/cm(2)-150 W/cm(2)), flow direction B perform best. Under the discussed condition, the heat flux value as 109.91 W/cm(2), 106.22 W/cm(2), and 143.05 W/cm(2) are the limit values for the CHF, in the square, droplet and non-closed droplet A pin fin arrays. Where, the CHF has not appeared in non-closed droplet B, whose limit value is more than 145 W/cm(.)(2) In general, the results illustrate that the opening structure is helpful for boiling heat transfer. The novel design can prolong the duration of bubble flow in nucleate boiling, which plays a key role in delaying CHF.
引用
收藏
页码:2087 / 2103
页数:17
相关论文
共 50 条
  • [21] THE INFLUENCE OF RAPID TRANSIENT HEATING IN CRITICAL HEAT FLUX OF BOILING HEAT TRANSFER
    Gao, Yuan
    Song, Zhuorui
    Villarreal, Ezekiel
    Ban, Heng
    PROCEEDINGS OF ASME 2021 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE2021), VOL 11, 2021,
  • [22] Enhancements of nucleate boiling and critical heat flux under microgravity conditions
    Zhang, NL
    Chao, DF
    Yang, WJ
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2001, 15 (03) : 326 - 332
  • [23] CRITICAL HEAT FLUX DURING FLOW BOILING IN MINI AND MICROCHANNEL-A STATE OF THE ART REVIEW
    Das, P. K.
    Chakraborty, S.
    Bhaduri, S.
    FRONTIERS IN HEAT AND MASS TRANSFER, 2012, 3 (01):
  • [24] EXPERIMENTAL CRITICAL HEAT FLUX MEASUREMENTS APPLIED TO A BOILING REACTOR CHANNEL
    MATZNER, B
    CASTERLI.JE
    MOECK, EO
    WIKHAMME.GA
    MECHANICAL ENGINEERING, 1967, 89 (01) : 62 - &
  • [25] Experimental study on saturated flow boiling critical heat flux in microchannels
    Kuan, Wai Keat
    Kandlikar, Satish G.
    Proceedings of the 4th International Conference on Nanochannels, Microchannnels, and Minichannels, Pts A and B, 2006, : 45 - 51
  • [26] Analysis of the critical heat flux of subcooled flow boiling in microgravity
    Liu, Bin
    Yuan, Bo
    Zhou, Jie
    Zhao, Jianfu
    Di Marco, Paolo
    Zhang, Yonghai
    Wei, Jinjia
    Yang, Yang
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2021, 120
  • [27] Experimental investigation of pool boiling heat transfer and critical heat flux of nanostructured surfaces
    Saeidi, D.
    Alemrajabi, A. A.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 60 : 440 - 449
  • [28] HEAT TRANSFER AND CRITICAL HEAT FLUX IN TRANSIENT BOILING .1. AN EXPERIMENTAL STUDY IN SATURATED POOL BOILING
    TACHIBANA, F
    AKIYAMA, M
    KAWAMURA, H
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY-TOKYO, 1968, 5 (03): : 117 - +
  • [29] CFD ANALYSIS OF FLOW BOILING IN A SILICON MICROCHANNEL WITH NON-UNIFORM HEAT FLUX
    Lorenzini, Daniel
    Joshi, Yogendra K.
    PROCEEDINGS OF THE ASME 13TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, 2015, 2015,
  • [30] Critical heat flux (CHF) in pool boiling under static and rolling conditions
    Tanjung, Elvira F.
    Albdour, Samah A.
    Jeong, Yeon Uk
    Jo, Daeseong
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (03) : 520 - 529