Ligament Tension and Balance before and after Robotic-Assisted Total Knee Arthroplasty - Dynamic Changes with Increasing Applied Force

被引:1
|
作者
Sharma, Abhinav K. K. [1 ]
Plaskos, Christopher [2 ]
Shalhoub, Sami [2 ]
Lawrence, Dylan [3 ]
Vigdorchik, Jonathan M. M. [4 ]
Lawrence, Jeffrey M. M. [5 ]
机构
[1] Univ Calif Irvine, Sch Med, Dept Orthopaed Surg, 101 The City Dr South,Pavil 3, Orange, CA 92868 USA
[2] Corin, Raynham, MA USA
[3] Univ Wisconsin, Dept Orthopaed & Rehabil, Madison, WI USA
[4] Hosp Special Surg, Dept Orthopaed Surg, New York, NY USA
[5] Gundersen Hlth Syst, Ctr Orthopaed Surg, Viroqua, WI USA
关键词
robotic-assisted; total knee arthroplasty; ligament balance; ligament tension; JOINT DISTRACTION FORCE; SOFT-TISSUE BALANCE; EXTENSION; STIFFNESS; FLEXION; TKA; SURGEON; LAXITY; FEMUR;
D O I
10.1055/s-0042-1760390
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The optimal force applied during ligament balancing in total knee arthroplasty (TKA) is not well understood. We quantified the effect of increasing distraction force on medial and lateral gaps throughout the range of knee motion, both prior to and after femoral resections in tibial-first gap-balancing TKA. Twenty-five consecutive knees in 21 patients underwent robotic-assisted TKA. The posterior cruciate ligament was resected, and the tibia was cut neutral to the mechanical axis. A digital ligament tensioning tool recorded gaps and applied equal mediolateral loads of 70 N (baseline), 90 N, and 110 N from 90 degrees to full extension. A gap-balancing algorithm planned the femoral implant position to achieve a balanced knee throughout flexion. After femoral resections, gap measurements were repeated under the same conditions. Paired t -tests identified gap differences between load levels, medial/lateral compartments, and flexion angle. Gaps increased from 0 to 20 degrees in flexion, then remain consistent through 90 degrees of flexion. Baseline medial gap was significantly smaller than lateral gap throughout flexion ( p < 0.05). Increasing load had a larger effect on the lateral versus medial gaps ( p < 0.05) and on flexion versus extension gaps. Increasing distraction force resulted in non-linear and asymmetric gap changes mediolaterally and from flexion to extension. Digital ligament tensioning devices can give better understanding of the relationship between joint distraction, ligament tension, and knee stiffness throughout the range of flexion. This can aid in informed surgical decision making and optimal soft tissue tensioning during TKA.
引用
收藏
页码:128 / 134
页数:7
相关论文
共 50 条
  • [41] Robotic-Assisted Total Knee Arthroplasty: What are Patients' Perspectives, Understanding and Expectations?
    Abdelaal, Mohammad S.
    Wiafe, Bright M.
    Khan, Irfan A.
    Magnuson, Justin A.
    Saxena, Arjun
    Smith, Eric B.
    Lonner, Jess H.
    Star, Andrew M.
    Good, Robert P.
    Sharkey, Peter F.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (09): : 1726 - 1733.e4
  • [42] Learning Curve in Robotic-Assisted Total Knee Arthroplasty: A Systematic Review of the Literature
    Cacciola, Giorgio
    Bosco, Francesco
    Giustra, Fortunato
    Risitano, Salvatore
    Capella, Marcello
    Bistolfi, Alessandro
    Masse, Alessandro
    Sabatini, Luigi
    APPLIED SCIENCES-BASEL, 2022, 12 (21):
  • [43] Robotic-assisted total knee arthroplasty: Is there a maximum level of efficiency for the operating surgeon?
    Patel, Kishan
    Judd, Hyrum
    Harm, Richard G.
    Nolan, Joseph R.
    Hummel, Matthew
    Spanyer, Jonathon
    JOURNAL OF ORTHOPAEDICS, 2022, 31 : 13 - 16
  • [44] Robotic-assisted total knee arthroplasty demonstrates decreased postoperative pain and opioid usage compared to conventional total knee arthroplasty
    Bhimani, S. J.
    Bhimani, R.
    Smith, A.
    Eccles, C.
    Smith, L.
    Malkani, A.
    BONE & JOINT OPEN, 2020, 1 (02): : 8 - 12
  • [45] Lengths of Stay and Discharge Dispositions after Total Knee Arthroplasty: A Comparison of Robotic-Assisted and Manual Techniques
    Archer, Allison
    Salem, Hytham S.
    Coppolecchia, Andrea
    Mont, Michael A.
    JOURNAL OF KNEE SURGERY, 2023, 36 (04) : 404 - 410
  • [46] Failure of the Femoral and Tibial Components Following Anterior Cruciate Ligament Injury After Robotic-Assisted Bicruciate-Retaining Total Knee Arthroplasty
    Shiga, Kosuke
    Kaneko, Takao
    Yamamoto, Ayakane
    Amemiya, Kazuki
    Omata, Masaru
    ARTHROPLASTY TODAY, 2024, 30
  • [47] Robotic-assisted total knee arthroplasty improved component alignment in the coronal plane compared with navigation-assisted total knee arthroplasty: a comparative study
    Yasuyuki Omichi
    Daisuke Hamada
    Keizo Wada
    Yasuaki Tamaki
    Shota Shigekiyo
    Koichi Sairyo
    Journal of Robotic Surgery, 2023, 17 : 2831 - 2839
  • [48] Robotic-assisted total knee arthroplasty improved component alignment in the coronal plane compared with navigation-assisted total knee arthroplasty: a comparative study
    Omichi, Yasuyuki
    Hamada, Daisuke
    Wada, Keizo
    Tamaki, Yasuaki
    Shigekiyo, Shota
    Sairyo, Koichi
    JOURNAL OF ROBOTIC SURGERY, 2023, 17 (06) : 2831 - 2839
  • [49] What are the benefits of robotic-assisted total knee arthroplasty over conventional manual total knee arthroplasty? A systematic review of comparative studies
    Mancino, Fabio
    Cacciola, Giorgio
    Malahias, Michael-Alexander
    De Filippis, Roberto
    De Marco, Davide
    Di Matteo, Vincenzo
    Gu, A.
    Sculco, Peter K.
    Maccauro, Giulio
    De Martino, Ivan
    ORTHOPEDIC REVIEWS, 2020, 12 : 15 - 22
  • [50] Robotic-assisted total knee arthroplasty in clinical practice: protocol for a randomised controlled trial
    Filippo Migliorini
    Nicola Maffulli
    Luise Schäfer
    Jens Schneider
    Andrea Maria Nobili
    Daniel Kämmer
    Milosch Michalak
    Andreas Bell
    Journal of Orthopaedic Surgery and Research, 18