Comparison of six-minute walk test and incremental shuttle walk test in interstitial lung disease

被引:0
|
作者
Pinar Deniz, Pelin [1 ,3 ]
Ergun, Pinar [2 ]
Erdogan, Yurdanur [2 ]
Yilmaz, Ulkii [2 ]
Biber, Cigdem [2 ]
Kaymaz, Dicle [2 ]
机构
[1] Cukurova Univ, Sch Med, Dept Chest Dis, Adana, Turkiye
[2] Ataturk Chest Dis & Thorac Surg Training & Res Hos, Dept Chest Dis, Ankara, Turkiye
[3] Cukurova Univ, Sch Med, Dept Chest Dis, TR-01370 Adana, Turkiye
来源
MINERVA RESPIRATORY MEDICINE | 2023年 / 62卷 / 02期
关键词
Pulmonary diffusing capacity; Lung diseases; interstitial; Walk test; CLINICAL DYSPNEA RATINGS; RESPIRATORY SENSATION; DISTANCE; REPRODUCIBILITY; PERFORMANCE; DIFFERENCE; VALIDATION;
D O I
10.23736/S2784-8477.22.02004-6
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
BACKGROUND: This study aimed to compare six-minute walk test (6-MWT) and incremental shuttle walk test (ISWT) in evaluating the exercise capacity and physiological responses of stable patients with interstitial lung disease (ILD). METHODS: Thirty patients diagnosed with ILD who were stable during the study period were included in the study. Demographic characteristics of the patients, lung function tests and carbon monoxide diffusion capacities were recorded. 6-MWT and ISWT were applied to the patients on different days, and physiological responses were evaluated. RESULTS: The mean age of the patients was 52.4 +/- 14 years, and 17 (56.7%) were men. The mean distances covered in the 1st hour and 2nd hour of 6-MWT were 418.2 +/- 137.4 m and 443.4 +/- 143.4 m, respectively, and the difference was statistically significant (P<0.001). ISWT mean distance was 266.3 +/- 148.3 m. The difference between oxygen saturations measured before and after 6-MWT and ISWT ( increment SaO2) was statistically significant (-7,-4) (P<0.001). Both 6-MWT and ISWT showed that there was a significant decrease in the exercise capacity of the patients with ILD, and there was a strong correlation between the walking distances measured in both tests (r=0.719, P<0.001). 6-MWT and ISWT walking distances showed the highest correlation with the maximum carbon monoxide diffusion capacity (DLCO) (%) (r=0.596, P<0.001 vs. r=0.666, P<0.001). CONCLUSIONS: 6-MWT and ISWT can be used to determine the exercise capacity in patients with ILD, and both tests show a strong correlation with DLCO, a parameter that has an important role in diagnosis, follow-up, treatment, and prognosis in this patient group. ISWT is a standardized test in which the maximal capacity is evaluated, it has a strong correlation with maximal and submaximal tests, and the peak oxygen consumption (V02 peak) calculated in this test shows a correlation with DLCO. Hence, ISWT is one step ahead in the follow-up of patients with ILD, monitoring treat-ment response, predicting survival and evaluating candidates for pulmonary rehabilitation program.
引用
收藏
页码:76 / 82
页数:7
相关论文
共 50 条
  • [41] Impact of HRCT pattern on six-minute walk test in patients with interstitial lung disease-An observational study
    Saxena, Puneet
    Singh, Itishree
    Kumar, Abhishek
    Kartik, S.
    Malik, Virender
    Tiwari, Saurabh
    Akhil, K. R.
    Pattanayak, Somali
    Velangi, Vaibhavi G.
    Jain, Harsh
    LUNG INDIA, 2023, 40 (05) : 429 - 433
  • [42] A comparison of the Endurance Shuttle Walk test and the Six Minute Walk test for assessment of exercise capacity in older people
    Witham, Miles D.
    Sugden, Jacqui A.
    Sumukadas, Deepa
    Dryburgh, Moira
    McMurdo, Marion E. T.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2012, 24 (02) : 176 - 180
  • [43] A comparison of the Endurance Shuttle Walk test and the Six Minute Walk test for assessment of exercise capacity in older people
    Miles D. Witham
    Jacqui A. Sugden
    Deepa Sumukadas
    Moira Dryburgh
    Marion E. T. McMurdo
    Aging Clinical and Experimental Research, 2012, 24 : 176 - 180
  • [44] A comparison of the Endurance Shuttle Walk test and the Six Minute Walk test for assessment of exercise capacity in older people
    Miles D. Witham
    Jacqui A. Sugden
    Deepa Sumukadas
    Moira Dryburgh
    Marion E. T. McMurdo
    Aging Clinical and Experimental Research, 2012, 24 (2) : 176 - 180
  • [45] Reliability, Validity, and Responsiveness of the Incremental Shuttle Walk Test in Patients With Interstitial Lung Disease
    Singh, Sumedha
    Moiz, Jamal Ali
    Ali, Mir Shad
    Talwar, Deepak
    JOURNAL OF CARDIOPULMONARY REHABILITATION AND PREVENTION, 2018, 38 (06) : 425 - 429
  • [46] Lung function and six-minute walk test performance in individuals with sickle cell disease
    Ohara, Daniela G.
    Ruas, Gualberto
    Walsh, Isabel A. P.
    Castro, Shamyr S.
    Jamami, Mauricio
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2014, 18 (01) : 79 - 87
  • [47] Six-minute walk test in diagnosis of COPD patients
    Petanjek, B. Butorac
    Popovic-Grle, S.
    Pavicic, F.
    Plavec, D.
    WIENER KLINISCHE WOCHENSCHRIFT, 2011, 123 (17-18) : A14 - A14
  • [48] Validity of the Six-Minute Walk Test in Cancer Patients
    Schmidt, K.
    Vogt, L.
    Thiel, C.
    Jaeger, E.
    Banzer, W.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2013, 34 (07) : 631 - 636
  • [49] The six-minute walk test in systemic sclerosis.
    Vonk, Madelon C.
    Heijdra, Yvonne F.
    Fransen, Jaap
    van Riel, Piet L. C. M.
    van den Hoogen, Frank H. J.
    ARTHRITIS AND RHEUMATISM, 2006, 54 (09): : S738 - S739
  • [50] ATS statement: Guidelines for the six-minute walk test
    Crapo, RO
    Casaburi, R
    Coates, AL
    Enright, PL
    MacIntyre, NR
    McKay, RT
    Johnson, D
    Wanger, JS
    Zeballos, RJ
    Bittner, V
    Mottram, C
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (01) : 111 - 117