Proteomic analysis of host cell protein fouling during bioreactor harvesting

被引:0
|
作者
Zhang, Da [1 ]
Wickramasinghe, S. Ranil [1 ]
Zydney, Andrew L. [2 ]
Smelko, John P. [3 ]
Loman, Abdullah [3 ]
Wheeler, April [4 ]
Qian, Xianghong [5 ]
机构
[1] Univ Arkansas, Ralph E Martin Dept Chem Engn, Fayetteville, AR USA
[2] Penn State Univ, Dept Chem Engn, University Pk, PA USA
[3] Biogen, Durham, NC USA
[4] Asahi Kasei Bioproc Amer, Glenview, IL USA
[5] Univ Arkansas, Dept Biomed Engn, Fayetteville, AR 72701 USA
基金
美国国家科学基金会;
关键词
bioreactor harvesting; filtration; host cell proteins; proteomic analysis; PERMEATE FLUX; CHO-CELLS; CULTURE; PERFUSION; MICROFILTRATION; IDENTIFICATION; IMPURITIES; FILTRATION; DYNAMICS; IMPACT;
D O I
10.1002/btpr.3453
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Chinese hamster ovary (CHO) cells are among the most common cell lines used for therapeutic protein production. Membrane fouling during bioreactor harvesting is a major limitation for the downstream purification of therapeutic proteins. Host cell proteins (HCP) are the most challenging impurities during downstream purification processes. The present work focuses on identification of HCP foulants during CHO bioreactor harvesting using reverse asymmetrical commercial membrane BioOptimal (TM) MF-SL. In order to investigate foulants and fouling behavior during cell clarification, for the first time a novel backwash process was developed to effectively elute almost all the HCP and DNA from the fouled membrane filter. The isoelectric points (pIs) and molecular weights (MWs) of major HCP in the bioreactor harvest and fouled on the membrane were successfully characterized using two-dimensional gel electrophoresis (2D SDS-PAGE). In addition, a total of 8 HCP were identified using matrix-assisted laser desorption/ionization-mass spectroscopy (MALDI-MS). The majority of these HCP are enzymes or associated with exosomes, both of which can form submicron-sized particles which could lead to the plugging of the filters.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] A bioreactor for in-cell protein NMR
    Sharaf, Naima G.
    Barnes, Christopher O.
    Charlton, Lisa M.
    Young, Gregory B.
    Pielak, Gary J.
    JOURNAL OF MAGNETIC RESONANCE, 2010, 202 (02) : 140 - 146
  • [42] The role of fouling mechanisms in a submerged membrane bioreactor during the start-up
    Di Bella, Gaetano
    Durante, Francesca
    Torregrossa, Michele
    Viviani, Gaspare
    DESALINATION, 2006, 200 (1-3) : 722 - 724
  • [43] Host cell protein analysis informs risk assessment
    Roberts J.P.
    Genetic Engineering and Biotechnology News, 2020, 40 (10): : 44 - 46and48
  • [44] New Tools in the Host Cell Protein Analysis Toolbox
    Macdonald G.J.
    Genetic Engineering and Biotechnology News, 2023, 43 (09): : 40 - 42
  • [45] Host Cell Protein Analysis Supports Process Development
    Macdonald G.J.
    Genetic Engineering and Biotechnology News, 2021, 41 (S3): : S10 - S11+S14
  • [46] Host cell protein analysis in therapeutic protein bioprocessing - methods and applications
    Tscheliessnig, Anne Luise
    Konrath, Julita
    Bates, Ron
    Jungbauer, Alois
    BIOTECHNOLOGY JOURNAL, 2013, 8 (06) : 655 - 670
  • [47] Evaluation of the fouling potential of sludge in a membrane bioreactor integrated with microbial fuel cell
    Li, Hui
    Xing, Yan
    Cao, Tengliang
    Dong, Jiangxue
    Liang, Shuxuan
    CHEMOSPHERE, 2021, 262
  • [48] Proteomic analysis of changes in mitochondrial protein expression during fruit senescence
    Qin, Guozheng
    Wang, Qing
    Liu, Jia
    Li, Boqiang
    Tian, Shiping
    PROTEOMICS, 2009, 9 (17) : 4241 - 4253
  • [49] Proteomic analysis of RBC membrane protein degradation during blood storage
    D'Amici, Gian Maria
    Rinalducci, Sara
    Zolla, Lello
    JOURNAL OF PROTEOME RESEARCH, 2007, 6 (08) : 3242 - 3255
  • [50] Alterations of protein expressions during migraine attacks revealed by proteomic analysis
    Nagata, E.
    Moriya, Y.
    Tsukamoto, H.
    Takizawa, S.
    Takagi, S.
    CEPHALALGIA, 2011, 31 (01) : 85 - 85