Intravenous lidocaine attenuates distention of the optical nerve sheath, a correlate of intracranial pressure, during endotracheal intubation

被引:2
|
作者
Maissan, Iscander M. [1 ]
Hollestelle, Rutger, V [1 ]
Rijs, Koen [1 ]
Jaspers, Selma [1 ]
Hoeks, Sanne [1 ]
Haitsma, Iain K. [2 ]
den Hartog, Dennis [3 ]
Stolker, Robert J. [1 ]
机构
[1] Erasmus MC, Dept Anesthesiol, Rotterdam, Netherlands
[2] Erasmus MC, Dept Neurosurg, Rotterdam, Netherlands
[3] Erasmus MC, Dept Surg, Trauma Res Unit, Rotterdam, Netherlands
关键词
Intracranial pressure; Brain injuries; traumatic; Lidocaine; Craniocerebral trauma; Randomized controlled trial; TRAUMATIC BRAIN-INJURY; CEREBROSPINAL-FLUID PRESSURE; TRACHEAL INTUBATION; ULTRASOUND; DIAMETER;
D O I
10.23736/S0375-9393.22.16574-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: By preventing hypoxia and hypercapnia, advanced airway management can save lives among patients with traumatic brain injury. During endotracheal intubation (ETI), tracheal stimulation causes an increase in intracranial pressure (ICP), which may impair brain perfusion. It has been suggested that intravenous lidocaine might attenuate this ICP response. We hypothesized that adding lidocaine to the standard induction medication for general anesthesia might reduce the ICP response to ETI. Here, we measured the optical nerve sheath diameter (ONSD) as a correlate of ICP and evaluated the effect of intravenous lidocaine on ONSD during and after ETI in patients undergoing anesthesia. METHODS: This double-blinded, randomized placebo-controlled trial included 60 patients with American Society of Anesthesiologists I or II physical status that were scheduled for elective surgery under general anesthesia. In addition to the standard anesthesia medication, 30 subjects received 1.5 mg/kg 1% lidocaine (0.15 mL/kg, ONSDlidocaine) and 30 re-ceived 0.15 mL/kg 0.9% NaCl (ONSDplacebo). ONSDs were measured with ultrasound on the left eye, before (T0), during (T1), and 4 times after ETI (T2-5 at 5-min intervals). RESULTS: Compared to placebo, lidocaine did not significantly affect the baseline ONSD after anesthesia induction measured at T0. During ETI, the ONSDlidocaine was significantly smaller (beta=-0.24 mm P=0.022) than the ONSDplacebo. At T4 and T5, the ONSDplacebo increased steadily, up to 20 min after ETI, but the ONSDlidocaine tended to return to baseline levels. CONCLUSIONS: We found that the ONSD was distended during and after ETI in anesthetized patients, and intravenous lidocaine attenuated this effect.
引用
收藏
页码:131 / 137
页数:7
相关论文
共 31 条
  • [21] Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure during laparoscopic surgery: a systematic review and meta-analysis
    Eun Jung Kim
    Bon-Nyeo Koo
    Seung Ho Choi
    Kyoungun Park
    Min-Soo Kim
    Surgical Endoscopy, 2018, 32 : 175 - 182
  • [22] Re: Increase in Intracranial Pressure During Carbon Dioxide Pneumoperitoneum with Steep Trendelenburg Positioning Proven by Ultrasonographic Measurement of Optic Nerve Sheath Diameter
    Chin, Ji-Hyun
    Choi, Dae-Kee
    Hwang, Jai-Hyun
    Kim, Young-Kug
    JOURNAL OF ENDOUROLOGY, 2015, 29 (01) : 100 - 101
  • [23] Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial
    Chin, Ji-Hyun
    Kim, Wook-Jong
    Lee, Joonho
    Han, Yun A.
    Lim, Jinwook
    Hwang, Jai-Hyun
    Cho, Seong-Sik
    Kim, Young-Kug
    PLOS ONE, 2017, 12 (01):
  • [24] Re: Increase in Intracranial Pressure During Carbon Dioxide Pneumoperitoneum with Steep Trendelenburg Positioning Proven by Ultrasonographic Measurement of Optic Nerve Sheath Diameter Authors' Response
    Kim, Min-Soo
    Choi, Seung Ho
    JOURNAL OF ENDOUROLOGY, 2015, 29 (01) : 101 - 101
  • [25] Effect of Mannitol on Ultrasonographically Measured Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure During Robot-Assisted Laparoscopic Prostatectomy with Pneumoperitoneum and the Trendelenburg Position
    Jun, In-Jung
    Kim, Myong
    Lee, Joonho
    Park, Se-Ung
    Hwang, Jai-Hyun
    Hong, Jun Hyuk
    Kim, Young-Kug
    JOURNAL OF ENDOUROLOGY, 2018, 32 (07) : 608 - 613
  • [26] Dexmedetomidine attenuates the increase of ultrasonographic optic nerve sheath diameter as a surrogate for intracranial pressure in patients undergoing robot-assisted laparoscopic prostatectomy A randomized double-blind controlled trial
    Yu, Jihion
    Park, Jun-Young
    Kim, Doo-Hwan
    Koh, Gi-Ho
    Jeong, Wonyeong
    Kim, Eunkyul
    Hong, Jun Hyuk
    Hwang, Jai-Hyun
    Kim, Young-Kug
    MEDICINE, 2019, 98 (33)
  • [27] A randomised trial to compare the increase in intracranial pressure as correlated with the optic nerve sheath diameter during propofol versus sevoflurane-maintained anesthesia in robot-assisted laparoscopic pelvic surgery
    Sujata, Nambiath
    Tobin, Raj
    Tamhankar, Ashwin
    Gautam, Gagan
    Yatoo, Abdul Hamid
    JOURNAL OF ROBOTIC SURGERY, 2019, 13 (02) : 267 - 273
  • [28] A randomised trial to compare the increase in intracranial pressure as correlated with the optic nerve sheath diameter during propofol versus sevoflurane-maintained anesthesia in robot-assisted laparoscopic pelvic surgery
    Nambiath Sujata
    Raj Tobin
    Ashwin Tamhankar
    Gagan Gautam
    Abdul Hamid Yatoo
    Journal of Robotic Surgery, 2019, 13 : 267 - 273
  • [29] Letter to the Editor: A randomised trial to compare the increase in intracranial pressure as correlated with the optic nerve sheath diameter during propofol versus sevoflurane-maintained anesthesia in robot-assisted laparoscopic pelvic surgery
    Di Paola, Ilenia
    Graziano, Mario
    Marotta, Giuseppe
    JOURNAL OF ROBOTIC SURGERY, 2023, 17 (02) : 703 - 704
  • [30] Letter to the Editor: A randomised trial to compare the increase in intracranial pressure as correlated with the optic nerve sheath diameter during propofol versus sevoflurane-maintained anesthesia in robot-assisted laparoscopic pelvic surgery
    Ilenia Di Paola
    Mario Graziano
    Giuseppe Marotta
    Journal of Robotic Surgery, 2023, 17 : 703 - 704