Seismic behaviour of Concrete-filled steel tubular column to H-Shape steel beam connection with side plate

被引:3
|
作者
Dong, Xitong [1 ,2 ,3 ]
Wang, Lai [1 ,2 ]
Xu, Zhifeng [1 ,2 ]
Guan, Shangshang [1 ,2 ]
Liu, Liyuan [1 ,2 ]
Chen, Haitao [1 ,2 ]
机构
[1] Shandong Univ Sci & Technol, Coll Civil Engn & Architecture, Qingdao 266590, Peoples R China
[2] Shandong Univ Sci & Technol, Shandong Key Lab Civil Engn Disaster Prevent & Mit, Qingdao 266590, Peoples R China
[3] Tianyuan Construct Grp Co Ltd, Linyi 276000, Peoples R China
基金
中国国家自然科学基金;
关键词
CFST column; Side plate connection; Reversed cyclic loading test; Seismic behaviour; Mechanism analysis;
D O I
10.1016/j.istruc.2023.02.089
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To ensure the quality of filled concrete and improve the indoor utilization rate of steel frame structure residential buildings, a novel concrete-filled steel tubular (CFST) column to H-shape steel beam connection with side plate was proposed in this study. Six specimens of 1/3 scale were tested under reversed cyclic loading. To evaluate the hysteretic performance, failure mode, ductility, stiffness degradation, strength degradation and energy dissipa-tion capacity. The evaluation parameters include the axial load ratio, and the side plate height and thickness. The results indicated that the failure mode mainly exhibited the steel beam buckling failure, making all hysteretic curves exhibit typically spindle-shaped. The equivalent viscous damping coefficient is 0.305-0.394. The average story drift angle at the ultimate stage is 1/31 similar to 1/37. It shows that all connections possess sufficient energy dissipation capacity and excellent ductility. The peak and ultimate load are significantly reduced with the in-crease of the axial load ratio. And the secant stiffness increases in the elastic stage with the rise of the thickness and height of the side plate. Finally, the failure mode, hysteresis curve, and envelope curve achieved from the finite element method(FEM) established in this paper are consistent with the test results. And the FEM disclosed that the beam flange stress is transferred to the side plate through the fillet weld, and the side plate stress is transferred to the column panel through the fillet weld.
引用
收藏
页码:1608 / 1624
页数:17
相关论文
共 50 条
  • [41] Experimental study on seismic performance of connection between U-shaped concrete-filled steel beam and concrete-filled steel plate shear wall
    Yang P.
    Luo J.
    Cheng R.
    Yu Y.
    Xu X.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 : 109 - 116
  • [42] Seismic performance of joint between steel H-beam and rectangular concrete-filled hot-rolled-steel tubular column
    Wang, Hanqin
    Jiang, Qing
    Huang, Zhipeng
    Huang, Junqi
    Chong, Xun
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2024,
  • [43] Theoretical analysis of a new-type connection between concrete-filled square steel tubular column and steel beam
    Miao Jikui
    Chen Zhihua
    Jiang Xinliang
    Li Liming
    8th International Conference on Steel-Concrete Composite and Hybrid Structures, Proceedings, 2006, : 398 - 403
  • [44] Seismic behaviors of embedded double-skin concrete-filled steel tubular column to foundation connection
    NCREE, Taipei 106, Taiwan
    不详
    Hunan Daxue Xuebao, 2006, SUPPL. (52-62):
  • [45] Flexural Capacity of Cross-Shaped Concrete-Filled Steel Tubular Column-Steel Beam Joints with Side-Plate Connections
    Zhao, Yi
    Li, Fuli
    Yan, Menghui
    Li, Qinglu
    SUSTAINABILITY, 2023, 15 (01)
  • [46] Tying behaviour of fin-plate connection to concrete-filled rectangular steel tubular column - Development of a simplified calculation method
    Jones, M. H.
    Wang, Y. C.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (01) : 1 - 10
  • [47] Experimental research on seismic behavior of new joint between concrete-filled square steel tubular column and steel beam
    Li, Nan
    Xi, Yajun
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING III, PT 1, 2014, 638-640 : 1923 - +
  • [48] Experimental research on seismic behavior of joints in the composite frame with concrete-filled steel square tubular column and steel beam
    Xu, Chengxiang
    Chen, Jianquan
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2010, 43 (SUPPL. 1): : 200 - 205
  • [49] Experiment on Seismic Behavior of Steel Reinforced Concrete-Filled Precast Concrete Tubular Column
    Du, Chuang (duch_1@sina.com), 2017, Tianjin University (50):
  • [50] Sensitivity Analysis of Continuous Web Plate Joint of Steel Beam to Concrete-Filled Steel Tubular Column Based on Correlation
    Pan, Jianrong
    Wang, Zhan
    Su, Cheng
    ADVANCED SCIENCE LETTERS, 2011, 4 (8-10) : 2957 - 2962